Difference between revisions of "Part:BBa K896009:Experience"
Line 1: | Line 1: | ||
− | |||
__NOTOC__ | __NOTOC__ | ||
This experience page is provided so that any user may enter their experience using this part.<BR>Please enter | This experience page is provided so that any user may enter their experience using this part.<BR>Please enter | ||
how you used this part and how it worked out. | how you used this part and how it worked out. | ||
+ | [[Image:flu 200.jpg]] | ||
+ | *Before 60 min, the fluorescence level of zinTp+GFP steadily increased, while BBa_I13522 (positive control) remained stable around 35000 au as time gone by. At 60 min, zinTp reached its maximum transcription rate so the fluorescence level stop increasing around 55000 au. | ||
+ | [[Image:Cd 15.jpg]] | ||
+ | *This fig shows the fluorescence level of different cadmium concentration. We can see that BBa_I13522 remained stable from different cadmium concentration, while the fluorescence level of zinTp+GFP increased as the cadmium concentration increased. We could also tell that the transcription rate of zinTp is fairly low when there is no cadmium ion. | ||
+ | |||
===Applications of BBa_K896009=== | ===Applications of BBa_K896009=== | ||
− | + | It can be use as Cd2+ biosensor. | |
===User Reviews=== | ===User Reviews=== | ||
<!-- DON'T DELETE --><partinfo>BBa_K896009 StartReviews</partinfo> | <!-- DON'T DELETE --><partinfo>BBa_K896009 StartReviews</partinfo> |
Latest revision as of 00:18, 27 September 2012
This experience page is provided so that any user may enter their experience using this part.
Please enter
how you used this part and how it worked out.
- Before 60 min, the fluorescence level of zinTp+GFP steadily increased, while BBa_I13522 (positive control) remained stable around 35000 au as time gone by. At 60 min, zinTp reached its maximum transcription rate so the fluorescence level stop increasing around 55000 au.
- This fig shows the fluorescence level of different cadmium concentration. We can see that BBa_I13522 remained stable from different cadmium concentration, while the fluorescence level of zinTp+GFP increased as the cadmium concentration increased. We could also tell that the transcription rate of zinTp is fairly low when there is no cadmium ion.
Applications of BBa_K896009
It can be use as Cd2+ biosensor.
User Reviews
UNIQ777f450e488aa244-partinfo-00000000-QINU UNIQ777f450e488aa244-partinfo-00000001-QINU