The graph below presents the results of the experiment described. The absorbance at 380nm for each of the different concentrations of the inducer in a range of 0.5 μM to 500 μM on a logarithmic scale. The absorbance was calculated via different dilutions of the samples: dilutions by 0.5, by 0.25, and by 0.1. The error bars represent the processing of the data collected. The line at the bottom of the graph represents the basal level according to the control result- no IPTG induction. <br>
 +
 +
As can be seen, the graph shows a small tendency to rise, but it's not clear enough.  There are several explanations, one is that saturation has been achieved from lowest concentration measured, which shows both that the assay is highly sensitive and that a small amount of polymerase is enough to cause translation. The experiment should be repeated with either lower concentrations of IPTG or Catechol. The line at the bottom of the graph represents the basal level according to the control result- no IPTG induction.
  
 
===User Reviews===
 
===User Reviews===

Revision as of 15:32, 23 September 2012

This experience page is provided so that any user may enter their experience using this part.
Please enter how you used this part and how it worked out.

Applications of BBa_K784001

The graph below presents the results of the experiment described. The absorbance at 380nm for each of the different concentrations of the inducer in a range of 0.5 μM to 500 μM on a logarithmic scale. The absorbance was calculated via different dilutions of the samples: dilutions by 0.5, by 0.25, and by 0.1. The error bars represent the processing of the data collected. The line at the bottom of the graph represents the basal level according to the control result- no IPTG induction.

As can be seen, the graph shows a small tendency to rise, but it's not clear enough. There are several explanations, one is that saturation has been achieved from lowest concentration measured, which shows both that the assay is highly sensitive and that a small amount of polymerase is enough to cause translation. The experiment should be repeated with either lower concentrations of IPTG or Catechol. The line at the bottom of the graph represents the basal level according to the control result- no IPTG induction.

User Reviews

UNIQ56aa421be7f552db-partinfo-00000000-QINU UNIQ56aa421be7f552db-partinfo-00000001-QINU