Difference between revisions of "Part:BBa I746907:Experience"

(TU_Munich Team 2011 GFP Assay)
(TU_Munich Team 2011 GFP Assay)
Line 19: Line 19:
 
change of medium to M63 (LB shows slight fluorescence itself)
 
change of medium to M63 (LB shows slight fluorescence itself)
  
 
+
excitation filter: 485 nm, emission filter: 520 nm
  
 
'''Problem''': measurement of Absorbance only every 100 minutes led to spikes in the diagram (Fluorescence measured every 10 min.)
 
'''Problem''': measurement of Absorbance only every 100 minutes led to spikes in the diagram (Fluorescence measured every 10 min.)

Revision as of 14:58, 21 September 2011

This experience page is provided so that any user may enter their experience using this part.
Please enter how you used this part and how it worked out.

Applications of BBa_I746907

User Reviews

TU_Munich Team 2011

We tested the part and it worked very well. 2011-09-19 GFP Assay Diagramm prozentual.jpg


TU_Munich Team 2011 GFP Assay

I746907 (T7 promotor with GFP) in pSB1A2 in BL21DE3 cells

change of medium to M63 (LB shows slight fluorescence itself)

excitation filter: 485 nm, emission filter: 520 nm

Problem: measurement of Absorbance only every 100 minutes led to spikes in the diagram (Fluorescence measured every 10 min.)

results

no concentration dependency of GFP induction as IPTG concentration was in saturation range

for this diagram:

  • calculation: Fluorescence/Absorbance
  • mean of triplicate measurement
  • adjusted to 100 %
  • corrected for outliers
  • shortened to 700 min


UNIQf5b06ff0b3f13f53-partinfo-00000000-QINU UNIQf5b06ff0b3f13f53-partinfo-00000001-QINU