Difference between revisions of "Part:BBa K343006:Experience"
(→Applications of BBa_K343006) |
|||
(4 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
__NOTOC__ | __NOTOC__ | ||
− | This | + | ==K343006== |
− | + | === HPLC determination of beta-carotene and retinal production === | |
+ | Apart from spectrophotometry, the resuspension of beta-carotene or retinal in acetone can be subjected to analysis by HPLC. HPLC can be used to separate retinal from beta-carotene, to get a better indication of whether or not our retinal-generating part actually produces retinal from beta-carotene.<br> | ||
+ | In this experiment cells were prepared and harvested according to protocol [http://2010.igem.org/Team:SDU-Denmark/protocols#EX1.2 EX1.2]. This experiment was performed with six different strains of ''E. coli'':<br> <br> | ||
+ | Wild type TOP10<br> | ||
+ | Wild type MG1655<br> | ||
+ | TOP10/pSB1A2-K274210 <br> | ||
+ | MG1655/pSB1A2-K274210<br> | ||
+ | TOP10/pSB1A2-K274210/pSB1C3-K343005<br> | ||
+ | MG1655/pSB1A2-K274210/pSB1C3-K343005<br> | ||
+ | Both K343005 and K274210 were constitutively expressed.<br><br> | ||
+ | MG1655 containing PSB1A2 with K274210 or PSB1C3 with K343005 were both under a constitutively active promotor<br> | ||
+ | The measurements were preformed on cells after 20 hours of growth. The resulting graphs is presented beneath the text.<br> | ||
+ | [[Image:Team SDU-Denmark-HPLC samples2.png|thumb|center|300px|'''Figure 4:''' HPLC analysis of samples from the 19th oct. 2010 Beta-carotene Peaks are clearly present, but no retinal peaks are observed. Measurements were made after 20 hours of growth]] | ||
+ | [[Image:Team SDU-Denmark-HPLC samples1.png|thumb|center|300px|'''Figure 5:''' HPLC analysis of samples from the 22nd oct. 2010 Beta-carotene Peaks are clearly pressent, but no retinal peaks are observed. Measurements were made after 20 hours of growth]]<br> | ||
+ | When looking at the retinal and beta-carotene standards analysed on the HPLC, peaks for both chemicals are clearly present. The retinal retention time is 3,480-3,490 minutes and the beta-carotene retention time is 23,300-23,600 minutes.<br> | ||
+ | The spectra for the first run of samples show large amounts of beta-carotene, smaller amounts of which also are products produced by the K274210 biobrick or absorbed form the media in the cells where the K274210 biobrick is absent.<br> | ||
+ | The spectra shows no measurable amounts of retinal in neither of the samples, but the samples produced by bacteria containing the K343006 brick have a lower amount of beta-carotene, which can indicated that either the bacterial production of beta-carotene is lowered or that some of the beta-carotene has been metabolized in the cell, either to a non-measurable concentration of Retinal or some other metabolite. It is also a possibility that the retinal is exported out of the cells.<br> | ||
+ | The spectra from the second run of samples again show large amounts of beta-carotene produced by the K274210 biobrick or absorbed form the media in the cells where the K274210 biobrick is absent.<br> | ||
+ | The only sample displaying any changes form the first run on the HPLC is TOP10 containing both the K343006 and K274210 biobricks. In the spectrum higher amounts of cell metabolites are still being produced by the K274210 biobrick but also others are produced by the cell. | ||
+ | In this spectra the peak with a retention time of 3,969 is close to the retention time of retinal form the standards but when examining the spectrum of the peak it can be concluded that it is not a retinal peak.<br> | ||
+ | <br> | ||
+ | In order to assess and quantify the results a standard dilution of beta-carotene and retinal was made and measured: 10 µM, 5 µM, 1 µM, 2 µM, 0,5 µM. The standard dilutions were also measured on the HPLC with the same injection volume and program as the samples. The resulting graphs are presented beneath <br> | ||
+ | [[Image:Team SDU-Denmark-HPLC standards1.png|400px|thumb|center| '''Figure 6:''' HPLC of standard dilutions of beta-carotene and retinal]] | ||
+ | <br> | ||
+ | When doing an HPLC analysis it is possible to quantify the amounts of the chemical compounds in the samples.<br> | ||
+ | This is done by generating a standard curve with known dilutions of the chemical and recording the area under the peaks. The peak area correspond to the concentration of the chemical in the sample.<br> | ||
+ | Then the area under the peaks is plotted on the y- axis, the know concentrations of the standards on the x-axis and the regression line is calculated.<br> | ||
+ | Now it is possible to calculate unknown concentrations from samples using the regression line from the standard curves.<br> | ||
+ | The results for our HPLC analysis can be seen beneath the text.<br> | ||
+ | [[Image:Team-SDU-Denmark-Amount of beta-carotene and retinal i standards.png|thumb|400px|center|'''Figure 7:''' Standard curve of area under the HPLC peaks against beta-carotene and retinal concentration. Regression lines were made.]] | ||
+ | From the equations for the regression line it is possible to calculate the amount of beta-carotene produced by bacteria grown for 20 hours in LB media.<br> | ||
+ | [[Image:Team-SDU-Denmark-Beta-carotene amounts.png|400px|thumb|center|'''Tabel 1:''' Showing calculatet beta-carotene content in samples]] | ||
+ | <br> | ||
+ | All data can be seen under [http://2010.igem.org/Image:Team-SDU-denmark-HPLC_determination_af_beta-carotene_and_retinal_production.zip Raw data]<br> | ||
+ | === Stability assay === | ||
+ | To determine the stability of our pSB1C3-K343006 plasmid, a stability experiment was carried out according to protocol [[http://2010.igem.org/Team:SDU-Denmark/protocols#Stability_assay SA1.1]]. ''E.coli'' MG1655/pSB1C3-K343006 was grown in LB media without chloramphenicol, whereby no selection pressure is exerted on the bacteria. Dilutions of the culture was spreaded onto LA plates and LA plates with 35µg/mL chloramphenicol, respectively, and the colony forming units (CFU) was determined for each plate. The CFU for the LA plates represents the total amount of bacteria in the culture, and the CFU of LA plates with chloramphenicol corresponds to the amount of plasmid carrying bacteria. The percentage of the total amount of bacteria carrying the plasmid was plotted in a semi-logarithmic graph as a function of number of generations.<br><br> | ||
+ | [[Image:Team-SDU- NinaB stab2.png|400px|thumb|center|'''Figure 8:''' Stability assay of ''E. coli'' strain MG1655-pSB1C3-K343006 showing that almost all cells have shed their plasmids within 20 generations, however some cells kept the plasmids for up to 40 generations.All data can be seen under [https://static.igem.org/mediawiki/2010/3/39/Team-SDU-_NinaB_stability_assay.ZIP Raw data]]]<br><br> | ||
+ | |||
+ | As seen in the graph, almost all of the bacteria had lost the plasmid after 20 generations, suggesting that the plasmid is only stable within the cell for a few generations (<20). This is presumably due to the strain brought upon the bacteria by the plasmid. Thereby when the bacteria are carrying a high-copy plasmid like pSB1C3-K343006 it is plausible that the bacteria will quickly lose the plasmid when no longer exposed to a selection pressure. | ||
+ | |||
+ | ===Growth assay=== | ||
+ | The purpose of this assay is to see if our transformants deviate from the wild type in growth rate. In the growth measurement assay we have measured OD at 550 nm every hour for 12 hours and at hour 24. In the experimental setup we used, no lag phase was observed in any of the measurements. | ||
+ | The graph below shows the growth of our wild type E. coli strain MG1655 and the MG1655/pSB1C3-K343006, respectively.<br><br> | ||
+ | [[Image: Team SDU-Denmark OD WT+NinaB.JPG|400px|thumb|center|'''Figure 9:''' Growth curve showing measured OD at 550nm. Samples were taken every hour over a 12 hour perion + one sample after 24 hours. In graph ''E. coli'' strain MG1655-pSB1C3-k343006 is compaired with Wild type ''E. coli'' strain MG1655 showing no significant difference between the three graphs. No Lag phase is seen.All data can be seen under [https://static.igem.org/mediawiki/2010/6/68/Team_SDU-Denmark_Growth_rate_assay_no._2_NinaB.zip Raw data]]] <br><br> | ||
+ | From our data we see no significant difference between the plasmid carrying bacteria and the wild type. This can be said to be quite contradictory to our results obtained from the stability assay. The transitory stability of pSB1C3-K343006 suggests that it is highly unfavorable for the bacteria, wherefore it might be expected that the growth of the bacteria containing this plasmid would be affected. Thus, however large a disadvantage the plasmid pose to the bacteria, their growth are not significantly influenced by the plasmid. The added reproduction load due to the plasmids, might also prolong the lag phase of the bacteria. Whether this is the case can not be concluded based on this experiment as no lag phase was observed in this experiment. | ||
+ | <br><br> | ||
===Applications of BBa_K343006=== | ===Applications of BBa_K343006=== | ||
− | [[media:Bielefeld_SDU_2010_BBa_K343006.pdf]] | + | The following link leads to the results of plasmid quality control analysis of the part BBa_K343006. 2010 iGEM Team Bielefeld-Germany tested the plasmid with capillary gel electrophoresis. A high ammount of the ccc monomer plasmid conformation is an strong indicator for well expressed genes. |
+ | |||
+ | [[media:Bielefeld_SDU_2010_BBa_K343006.pdf |CGE analysis data]] | ||
===User Reviews=== | ===User Reviews=== |
Latest revision as of 18:29, 5 November 2010
K343006
HPLC determination of beta-carotene and retinal production
Apart from spectrophotometry, the resuspension of beta-carotene or retinal in acetone can be subjected to analysis by HPLC. HPLC can be used to separate retinal from beta-carotene, to get a better indication of whether or not our retinal-generating part actually produces retinal from beta-carotene.
In this experiment cells were prepared and harvested according to protocol [http://2010.igem.org/Team:SDU-Denmark/protocols#EX1.2 EX1.2]. This experiment was performed with six different strains of E. coli:
Wild type TOP10
Wild type MG1655
TOP10/pSB1A2-K274210
MG1655/pSB1A2-K274210
TOP10/pSB1A2-K274210/pSB1C3-K343005
MG1655/pSB1A2-K274210/pSB1C3-K343005
Both K343005 and K274210 were constitutively expressed.
MG1655 containing PSB1A2 with K274210 or PSB1C3 with K343005 were both under a constitutively active promotor
The measurements were preformed on cells after 20 hours of growth. The resulting graphs is presented beneath the text.
When looking at the retinal and beta-carotene standards analysed on the HPLC, peaks for both chemicals are clearly present. The retinal retention time is 3,480-3,490 minutes and the beta-carotene retention time is 23,300-23,600 minutes.
The spectra for the first run of samples show large amounts of beta-carotene, smaller amounts of which also are products produced by the K274210 biobrick or absorbed form the media in the cells where the K274210 biobrick is absent.
The spectra shows no measurable amounts of retinal in neither of the samples, but the samples produced by bacteria containing the K343006 brick have a lower amount of beta-carotene, which can indicated that either the bacterial production of beta-carotene is lowered or that some of the beta-carotene has been metabolized in the cell, either to a non-measurable concentration of Retinal or some other metabolite. It is also a possibility that the retinal is exported out of the cells.
The spectra from the second run of samples again show large amounts of beta-carotene produced by the K274210 biobrick or absorbed form the media in the cells where the K274210 biobrick is absent.
The only sample displaying any changes form the first run on the HPLC is TOP10 containing both the K343006 and K274210 biobricks. In the spectrum higher amounts of cell metabolites are still being produced by the K274210 biobrick but also others are produced by the cell.
In this spectra the peak with a retention time of 3,969 is close to the retention time of retinal form the standards but when examining the spectrum of the peak it can be concluded that it is not a retinal peak.
In order to assess and quantify the results a standard dilution of beta-carotene and retinal was made and measured: 10 µM, 5 µM, 1 µM, 2 µM, 0,5 µM. The standard dilutions were also measured on the HPLC with the same injection volume and program as the samples. The resulting graphs are presented beneath
When doing an HPLC analysis it is possible to quantify the amounts of the chemical compounds in the samples.
This is done by generating a standard curve with known dilutions of the chemical and recording the area under the peaks. The peak area correspond to the concentration of the chemical in the sample.
Then the area under the peaks is plotted on the y- axis, the know concentrations of the standards on the x-axis and the regression line is calculated.
Now it is possible to calculate unknown concentrations from samples using the regression line from the standard curves.
The results for our HPLC analysis can be seen beneath the text.
From the equations for the regression line it is possible to calculate the amount of beta-carotene produced by bacteria grown for 20 hours in LB media.
All data can be seen under [http://2010.igem.org/Image:Team-SDU-denmark-HPLC_determination_af_beta-carotene_and_retinal_production.zip Raw data]
Stability assay
To determine the stability of our pSB1C3-K343006 plasmid, a stability experiment was carried out according to protocol http://2010.igem.org/Team:SDU-Denmark/protocols#Stability_assay SA1.1. E.coli MG1655/pSB1C3-K343006 was grown in LB media without chloramphenicol, whereby no selection pressure is exerted on the bacteria. Dilutions of the culture was spreaded onto LA plates and LA plates with 35µg/mL chloramphenicol, respectively, and the colony forming units (CFU) was determined for each plate. The CFU for the LA plates represents the total amount of bacteria in the culture, and the CFU of LA plates with chloramphenicol corresponds to the amount of plasmid carrying bacteria. The percentage of the total amount of bacteria carrying the plasmid was plotted in a semi-logarithmic graph as a function of number of generations.
As seen in the graph, almost all of the bacteria had lost the plasmid after 20 generations, suggesting that the plasmid is only stable within the cell for a few generations (<20). This is presumably due to the strain brought upon the bacteria by the plasmid. Thereby when the bacteria are carrying a high-copy plasmid like pSB1C3-K343006 it is plausible that the bacteria will quickly lose the plasmid when no longer exposed to a selection pressure.
Growth assay
The purpose of this assay is to see if our transformants deviate from the wild type in growth rate. In the growth measurement assay we have measured OD at 550 nm every hour for 12 hours and at hour 24. In the experimental setup we used, no lag phase was observed in any of the measurements.
The graph below shows the growth of our wild type E. coli strain MG1655 and the MG1655/pSB1C3-K343006, respectively.
From our data we see no significant difference between the plasmid carrying bacteria and the wild type. This can be said to be quite contradictory to our results obtained from the stability assay. The transitory stability of pSB1C3-K343006 suggests that it is highly unfavorable for the bacteria, wherefore it might be expected that the growth of the bacteria containing this plasmid would be affected. Thus, however large a disadvantage the plasmid pose to the bacteria, their growth are not significantly influenced by the plasmid. The added reproduction load due to the plasmids, might also prolong the lag phase of the bacteria. Whether this is the case can not be concluded based on this experiment as no lag phase was observed in this experiment.
Applications of BBa_K343006
The following link leads to the results of plasmid quality control analysis of the part BBa_K343006. 2010 iGEM Team Bielefeld-Germany tested the plasmid with capillary gel electrophoresis. A high ammount of the ccc monomer plasmid conformation is an strong indicator for well expressed genes.
User Reviews
UNIQb7f871012097b941-partinfo-00000000-QINU UNIQb7f871012097b941-partinfo-00000001-QINU