Difference between revisions of "Part:BBa K5492722:Design"
(→References) |
|||
(5 intermediate revisions by 2 users not shown) | |||
Line 7: | Line 7: | ||
===Design Notes=== | ===Design Notes=== | ||
− | + | [https://parts.igem.org/Part:BBa_K5492712 s1 ssDNA aptamer] sequence designed to specifically bind to histamine. | |
− | + | The sequence contains a fluorophore molecule at its 5' end. | |
− | + | [https://parts.igem.org/Part:BBa_K5492732 s1_reverse_compliment_strand] is complementary to this sequnce, which contains a quencher molecule which absorbs the light emitted by fluorophore until the aptamer binds histamine. | |
− | + | ||
===Source=== | ===Source=== | ||
Line 17: | Line 16: | ||
===References=== | ===References=== | ||
+ | http://www.unafold.org/mfold/applications/dna-folding-form.php - Folding | ||
+ | |||
Reference: Zhang, H.; Lai, Y.; Wang, L.; Chen, Z.; Wang, Z. High-Throughput Screening of DNA Aptamers for Bisphenol A Detection Based on Circular Dichroism and Fluorescence. Anal. Chem. 2019, 91 (10), 6581–6588. DOI: 10.1021/acs.analchem.9b00075. | Reference: Zhang, H.; Lai, Y.; Wang, L.; Chen, Z.; Wang, Z. High-Throughput Screening of DNA Aptamers for Bisphenol A Detection Based on Circular Dichroism and Fluorescence. Anal. Chem. 2019, 91 (10), 6581–6588. DOI: 10.1021/acs.analchem.9b00075. |
Latest revision as of 21:48, 1 October 2024
S1_aptamer_with_fluorophore
- 10COMPATIBLE WITH RFC[10]
- 12COMPATIBLE WITH RFC[12]
- 21COMPATIBLE WITH RFC[21]
- 23COMPATIBLE WITH RFC[23]
- 25COMPATIBLE WITH RFC[25]
- 1000COMPATIBLE WITH RFC[1000]
Design Notes
s1 ssDNA aptamer sequence designed to specifically bind to histamine. The sequence contains a fluorophore molecule at its 5' end. s1_reverse_compliment_strand is complementary to this sequnce, which contains a quencher molecule which absorbs the light emitted by fluorophore until the aptamer binds histamine.
Source
https://pubs.acs.org/doi/abs/10.1021/acs.analchem.9b00075 Reference: Zhang, H.; Lai, Y.; Wang, L.; Chen, Z.; Wang, Z. High-Throughput Screening of DNA Aptamers for Bisphenol A Detection Based on Circular Dichroism and Fluorescence. Anal. Chem. 2019, 91 (10), 6581–6588. DOI: 10.1021/acs.analchem.9b00075.
References
http://www.unafold.org/mfold/applications/dna-folding-form.php - Folding
Reference: Zhang, H.; Lai, Y.; Wang, L.; Chen, Z.; Wang, Z. High-Throughput Screening of DNA Aptamers for Bisphenol A Detection Based on Circular Dichroism and Fluorescence. Anal. Chem. 2019, 91 (10), 6581–6588. DOI: 10.1021/acs.analchem.9b00075.