Difference between revisions of "Part:BBa K4438122"
Neha adarsh (Talk | contribs) |
|||
(3 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
<partinfo>BBa_K4438122 short</partinfo> | <partinfo>BBa_K4438122 short</partinfo> | ||
− | FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. This part is the expression | + | FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. This part is the expression cassette for <partinfo>BBa_K4438102</partinfo> with <partinfo>BBa_J64997</partinfo> upstream and <partinfo>BBa_K731721</partinfo> downstream along with some spacer sequences <partinfo>BBa_K3831027</partinfo> (at 5’ end) and <partinfo>BBa_K4438136</partinfo> (at 3’ end). FASTmiR-222-D3_s, after transcription, binds to miR-222, the transcription product of <partinfo>BBa_K4438150</partinfo>. The binding of these to RNAs will lead to the revelation of a binding site for DFHBI, a fluorophore, where it gets trapped and shows fluorescence. |
===Usage and Biology=== | ===Usage and Biology=== | ||
− | This part can be used for the detection of miR-222, which proves to be a biomarker for many diseases. A promoter sequence added in the beginning enhances its usage in both in-vivo and in-vitro conditions. The | + | This part can be used for the detection of miR-222, which proves to be a biomarker for many diseases. A promoter sequence added in the beginning enhances its usage in both in-vivo and in-vitro conditions. The OFF(A) and ON(B) structure for the sensor was generated as given: |
− | + | [[File:T--IISER-Tirupati_India--miRNA_222_3.png]] | |
<!-- --> | <!-- --> |
Latest revision as of 11:25, 12 October 2022
FASTmiR-222-D3_s
FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. This part is the expression cassette for BBa_K4438102 with BBa_J64997 upstream and BBa_K731721 downstream along with some spacer sequences BBa_K3831027 (at 5’ end) and BBa_K4438136 (at 3’ end). FASTmiR-222-D3_s, after transcription, binds to miR-222, the transcription product of BBa_K4438150. The binding of these to RNAs will lead to the revelation of a binding site for DFHBI, a fluorophore, where it gets trapped and shows fluorescence.
Usage and Biology
This part can be used for the detection of miR-222, which proves to be a biomarker for many diseases. A promoter sequence added in the beginning enhances its usage in both in-vivo and in-vitro conditions. The OFF(A) and ON(B) structure for the sensor was generated as given:
Sequence and Features
- 10INCOMPATIBLE WITH RFC[10]Illegal SpeI site found at 98
- 12INCOMPATIBLE WITH RFC[12]Illegal NheI site found at 176
Illegal SpeI site found at 98 - 21COMPATIBLE WITH RFC[21]
- 23INCOMPATIBLE WITH RFC[23]Illegal SpeI site found at 98
- 25INCOMPATIBLE WITH RFC[25]Illegal SpeI site found at 98
- 1000COMPATIBLE WITH RFC[1000]
Notes
The split position of the complementary sequence in the sensor is ACCCAGTAG.…CCAGAGTGAGCT
References
Huang, K., Doyle, F., Wurz, Z. E., Tenenbaum, S. A., Hammond, R. K., Caplan, J. L., & Meyers, B. C. (2017). FASTmiR: an RNA-based sensor for in vitro quantification and live-cell localization of small RNAs. Nucleic acids research, 45(14), e130-e130