Difference between revisions of "Part:BBa K4438106"
(One intermediate revision by the same user not shown) | |||
Line 3: | Line 3: | ||
<partinfo>BBa_K4438106 short</partinfo> | <partinfo>BBa_K4438106 short</partinfo> | ||
− | FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. FASTmiR-146a-D2, after transcription, binds to miR-146a, the transcription product of | + | FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. FASTmiR-146a-D2, after transcription, binds to miR-146a, the transcription product of <partinfo>BBa_K4438151</partinfo>. The binding of these to RNAs will lead to the revelation of a binding site for DFHBI, a fluorophore, where it gets trapped and shows fluorescence. |
===Usage and Biology=== | ===Usage and Biology=== | ||
− | This part can be used for the detection of miR-146a, which proves to be a biomarker for many diseases. The ON | + | This part can be used for the detection of miR-146a, which proves to be a biomarker for many diseases. The OFF(A) and ON(B) structure for the sensor was generated as given: |
− | [[File: | + | [[File:T--IISER-Tirupati_India--miRNA_146_2.png]] |
<!-- --> | <!-- --> | ||
<span class='h3bb'>Sequence and Features</span> | <span class='h3bb'>Sequence and Features</span> |
Latest revision as of 10:59, 12 October 2022
FASTmiR-146a-D2
FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. FASTmiR-146a-D2, after transcription, binds to miR-146a, the transcription product of BBa_K4438151. The binding of these to RNAs will lead to the revelation of a binding site for DFHBI, a fluorophore, where it gets trapped and shows fluorescence.
Usage and Biology
This part can be used for the detection of miR-146a, which proves to be a biomarker for many diseases. The OFF(A) and ON(B) structure for the sensor was generated as given: Sequence and Features
- 10INCOMPATIBLE WITH RFC[10]Illegal SpeI site found at 51
- 12INCOMPATIBLE WITH RFC[12]Illegal SpeI site found at 51
- 21COMPATIBLE WITH RFC[21]
- 23INCOMPATIBLE WITH RFC[23]Illegal SpeI site found at 51
- 25INCOMPATIBLE WITH RFC[25]Illegal SpeI site found at 51
- 1000COMPATIBLE WITH RFC[1000]
Notes
The split position of the complementary sequence in the sensor is CTGAAGAACTGA….ATTTCAGAGG
References
Huang, K., Doyle, F., Wurz, Z. E., Tenenbaum, S. A., Hammond, R. K., Caplan, J. L., & Meyers, B. C. (2017). FASTmiR: an RNA-based sensor for in vitro quantification and live-cell localization of small RNAs. Nucleic acids research, 45(14), e130-e130