Difference between revisions of "Part:BBa K4340612"

 
(One intermediate revision by the same user not shown)
Line 19: Line 19:
 
         [[File:PHS-pH-9.png|400px|thumb|center|Figure 3. The pH change of genetic pH shooting system_pET11a in the pH 9 initial environment]]
 
         [[File:PHS-pH-9.png|400px|thumb|center|Figure 3. The pH change of genetic pH shooting system_pET11a in the pH 9 initial environment]]
 
          
 
          
 
+
[[File:PHS 2.png|400px|thumb|center|Photo 1: The pH adjusted LB broth for pH changes test.]]
  
 
       <p>In the initial pH 7 environment, the pH curve of both groups are relatively similar, showing that the system does not function in a pH 7 environment, which conforms to the promoter design (Pasr for acidic environment and P-atp2 for alkaline environment) (Figure 1) </p>
 
       <p>In the initial pH 7 environment, the pH curve of both groups are relatively similar, showing that the system does not function in a pH 7 environment, which conforms to the promoter design (Pasr for acidic environment and P-atp2 for alkaline environment) (Figure 1) </p>

Latest revision as of 10:17, 11 October 2022


P-atp2 Mutant 154

This is an alkaline promoter P-atp2, Mutant 154

P-atp2 is the promoter of the alkaline shooting circuit (with ldhA lactic acid producer) in the genetic pH shooting system.

genetic pH shooting system (BBa_K4340609) and pET11a empty vector pH maintenance functional test

Experiment 1: pH change and OD value

Figure 1. The pH change of genetic pH shooting system_pET11a in the pH 7 initial environment


Figure 2. The pH change of genetic pH shooting system_pET11a in the pH 8 initial environment


Figure 3. The pH change of genetic pH shooting system_pET11a in the pH 9 initial environment
Photo 1: The pH adjusted LB broth for pH changes test.

In the initial pH 7 environment, the pH curve of both groups are relatively similar, showing that the system does not function in a pH 7 environment, which conforms to the promoter design (Pasr for acidic environment and P-atp2 for alkaline environment) (Figure 1)

In both initial pH 8 and pH 9, the pH level of the genetic pH shooting system drops more than the control group (pET11a). This demonstrated that the base shooting circuit functioned to neutralize the alkaline environment. (Figure 2 & 3)

Figure 4. The OD change of genetic pH shooting system_pET11a in the pH 7 initial environment


Figure 5. The OD change of genetic pH shooting system_pET11a in the pH 8 initial environment


Figure 6. The OD change of genetic pH shooting system_pET11a in the pH 9 initial environment


For the OD change of the genetic pH shooting system, The highest OD value is in the pH 7 environment, followed by pH 8, and pH 9. The OD value of pH 9 is lower than the other pH groups (pH 7, 8, and 9 of the genetic pH shooting system), which shows that the transformed E.coli might not grow as well as E.coli with an empty pET11a vector since it has to produce alkaline.

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    COMPATIBLE WITH RFC[1000]