Difference between revisions of "Part:BBa K4441005"

 
 
(3 intermediate revisions by the same user not shown)
Line 3: Line 3:
 
<partinfo>BBa_K4441005 short</partinfo>
 
<partinfo>BBa_K4441005 short</partinfo>
  
129 150 22 60.59 -4.29 -5.35 41 ATCAGTTTGAACAGTTGTCTGG
+
Sequence used in wetlab experiments: TCTGACTGAAAGCTGTATGG is taken from [1]
  
<!-- Add more about the biology of this part here
 
 
===Usage and Biology===
 
===Usage and Biology===
 +
This is the sequence for the outer backward primer. The outer backward primer consists of a B3 region which is complementary to the B3c region of the template sequence [2]. The outer primer B3 hybridizes to B3c region of the target DNA and extends, displacing the BIP linked complementary strand and resulting in the formation of a dumbbell shaped DNA [2]. This B3 primer is part of the primer set that detects the BRAF V600E:
 +
TTACTTACACGCCAAGTCAATCATCCACAGAGACCTCAAGAGTAATAATATATTTCTTCATGAAGACCTCACAGTAAAAATAGGTGATTTTGGTCTAGCTACAGAGAAATCTCGATGGA
 +
GTGGGTCCCATCAGTTTGAACAGTTGTCTGGATCCATTTTGTGGATGGCACCAGAAGTCATCAGAATGCAAGATAAAAATCCATACAGCTTTCAGTCAGATGTATATGCATTTGGAATT
 +
GTTCTGTATGAATTGATGACTGGACAGTTACCTTATTCAAACATCAACAACAGGGACCAG
 +
 +
====Dilutions====
 +
 +
Storage Primer Concentration: 100 μM
 +
 +
10X Concentration (Stock): 16 μM
 +
 +
Volume of 10X primer mix: 10 μL
 +
 +
1X Concentration (Final): 1.6 μM
 +
 +
Volume of storage primer needed: 0.2 μL
 +
 +
Mixed with F3, FIP, BIP, LF and LB for a total of 4.4 μL -- Final primer mix
 +
1 μL of final primer mix is used in the LAMP reaction mix. For more information, visit https://2022.igem.org/Team:Washington
 +
 +
====Alternative Sequence====
 +
As this set of primer failed to produce a positive result, we used NEB LAMP Primer Design Tool (https://lamp.neb.com/#!/) to generate an alternative set of primers. Unfortunately, due to time and budgetary constraints, these primers have not been ordered and experimented with yet.
 +
 +
Sequence: TCTGACTGAAAGCTGTATGG
 +
 +
5′ pos: 200
 +
 +
3′ pos: 21
 +
 +
len: 20
 +
 +
Tm: 56.40
 +
 +
5′ dG: -4.76
 +
 +
3′ dG: -4.23
 +
 +
% GC: 45
 +
 +
==Citations==
 +
1. Papadakis, G., Pantazis, A. K., Fikas, N., Chatziioannidou, S., Tsiakalou, V., Michaelidou, K., ... & Gizeli, E. (2022). Portable real-time colorimetric LAMP-device for rapid quantitative detection of nucleic acids in crude samples. Scientific reports, 12(1), 1-15.
 +
 +
2. Loop mediated isothermal amplification - technote. (n.d.). Retrieved October 11, 2022, from http://www.premierbiosoft.com/tech_notes/Loop-Mediated-Isothermal-Amplification.html
  
 
<!-- -->
 
<!-- -->
 
<span class='h3bb'>Sequence and Features</span>
 
<span class='h3bb'>Sequence and Features</span>
 
<partinfo>BBa_K4441005 SequenceAndFeatures</partinfo>
 
<partinfo>BBa_K4441005 SequenceAndFeatures</partinfo>
 
+
Sequence: TCTGACTGAAAGCTGTATGG
  
 
<!-- Uncomment this to enable Functional Parameter display  
 
<!-- Uncomment this to enable Functional Parameter display  

Latest revision as of 20:02, 13 October 2022


BRAF V600E B3

Sequence used in wetlab experiments: TCTGACTGAAAGCTGTATGG is taken from [1]

Usage and Biology

This is the sequence for the outer backward primer. The outer backward primer consists of a B3 region which is complementary to the B3c region of the template sequence [2]. The outer primer B3 hybridizes to B3c region of the target DNA and extends, displacing the BIP linked complementary strand and resulting in the formation of a dumbbell shaped DNA [2]. This B3 primer is part of the primer set that detects the BRAF V600E: TTACTTACACGCCAAGTCAATCATCCACAGAGACCTCAAGAGTAATAATATATTTCTTCATGAAGACCTCACAGTAAAAATAGGTGATTTTGGTCTAGCTACAGAGAAATCTCGATGGA GTGGGTCCCATCAGTTTGAACAGTTGTCTGGATCCATTTTGTGGATGGCACCAGAAGTCATCAGAATGCAAGATAAAAATCCATACAGCTTTCAGTCAGATGTATATGCATTTGGAATT GTTCTGTATGAATTGATGACTGGACAGTTACCTTATTCAAACATCAACAACAGGGACCAG

Dilutions

Storage Primer Concentration: 100 μM

10X Concentration (Stock): 16 μM

Volume of 10X primer mix: 10 μL

1X Concentration (Final): 1.6 μM

Volume of storage primer needed: 0.2 μL

Mixed with F3, FIP, BIP, LF and LB for a total of 4.4 μL -- Final primer mix 1 μL of final primer mix is used in the LAMP reaction mix. For more information, visit https://2022.igem.org/Team:Washington

Alternative Sequence

As this set of primer failed to produce a positive result, we used NEB LAMP Primer Design Tool (https://lamp.neb.com/#!/) to generate an alternative set of primers. Unfortunately, due to time and budgetary constraints, these primers have not been ordered and experimented with yet.

Sequence: TCTGACTGAAAGCTGTATGG

5′ pos: 200

3′ pos: 21

len: 20

Tm: 56.40

5′ dG: -4.76

3′ dG: -4.23

% GC: 45

Citations

1. Papadakis, G., Pantazis, A. K., Fikas, N., Chatziioannidou, S., Tsiakalou, V., Michaelidou, K., ... & Gizeli, E. (2022). Portable real-time colorimetric LAMP-device for rapid quantitative detection of nucleic acids in crude samples. Scientific reports, 12(1), 1-15.

2. Loop mediated isothermal amplification - technote. (n.d.). Retrieved October 11, 2022, from http://www.premierbiosoft.com/tech_notes/Loop-Mediated-Isothermal-Amplification.html

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    COMPATIBLE WITH RFC[1000]

Sequence: TCTGACTGAAAGCTGTATGG