===Lambert_GA 2021===
 
===Lambert_GA 2021===
Utilizing the modified phosphate range and characterization protocol (See: [https://2021.igem.org/Team:Lambert_GA/Pho#:~:text=Engineering%20Success%20page.-,Characterization%20Protocol,-The%20failed%20characterization Modified Protocol]), we characterized the BBa_K2447000 phosphate sensor. The characterization curve (Figure 1) showed a linear, negative trend throughout phosphate concentrations ranging from 0-100μM. This data closely paralleled the predictive ODE model created by our 2020 team and the previous characterization data by NUS Singapore iGEM 2017.  
+
Utilizing the phosphate range of 0-100μM and characterization protocol (See: [https://2021.igem.org/Team:Lambert_GA/Pho#:~:text=Engineering%20Success%20page.-,Characterization%20Protocol,-The%20failed%20characterization Modified Protocol]), we characterized the [https://parts.igem.org/Part:BBa_K2447000 BBa_K2447000] phosphate sensor. The characterization curve (Figure 1) showed a linear, negative trend throughout phosphate concentrations ranging from 0-100μM. This data closely paralleled the predictive ODE model created by our 2020 team and the previous characterization data by NUS Singapore iGEM 2017.  
 +
 
 +
<br>
  
 
[[File:Fjasknfkncjak.png|thumb|center|800px|Figure 1. Characterization curve for BBa_K2447000 for phosphate concentrations between 0μM and 100μM. ]]
 
[[File:Fjasknfkncjak.png|thumb|center|800px|Figure 1. Characterization curve for BBa_K2447000 for phosphate concentrations between 0μM and 100μM. ]]

Latest revision as of 20:36, 17 December 2021


This experience page is provided so that any user may enter their experience using this part.
Please enter how you used this part and how it worked out.

Lambert_GA 2021

Utilizing the phosphate range of 0-100μM and characterization protocol (See: Modified Protocol), we characterized the BBa_K2447000 phosphate sensor. The characterization curve (Figure 1) showed a linear, negative trend throughout phosphate concentrations ranging from 0-100μM. This data closely paralleled the predictive ODE model created by our 2020 team and the previous characterization data by NUS Singapore iGEM 2017.


Figure 1. Characterization curve for BBa_K2447000 for phosphate concentrations between 0μM and 100μM.

User Reviews