Difference between revisions of "Part:BBa K3777021"
(5 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
<partinfo>BBa_K3777021 short</partinfo> | <partinfo>BBa_K3777021 short</partinfo> | ||
− | + | Basic biosensor device for erythromycin detection. | |
− | + | ||
− | + | ||
− | + | ||
+ | <!-- Add more about the biology of this part here--> | ||
+ | <b><font size="3">Usage and Biology</font></b> | ||
+ | <br>The genetic circuit was composed of a coding sequence of erythromycin repressor and ermc genes which was inserted into an expression vectors with a consitive promoter(BBa_J23114) and RBS(BBa_K3777030), as well as 3WJdB(BBa_K3777000) under the control of T7 promoter (BBa_K3777006). The terminator we used were BBa_B0010 and BBa_M36305.(Fig 1) | ||
+ | <br>When Ery was absent, TetR would bind to the inducible promoter(PI)and prevent RNA polymerase from initiating transcription, thus repressing the expression of reporter gene. If tet was present, TetR would no longer able to bind to the promoter, resulting in the expression of reporter gene. | ||
+ | <br>We expressed this circuit in the <i>E. coli </i> BL21(DE3) cells for tetracycline detection. Thus we could roughly deduce the concentration of the antibiotics in the sample according to the fluorescence intensity. | ||
+ | https://static.igem.org/mediawiki/parts/thumb/f/fc/MphR-ermC-T7%28mphO%29-3WJdB.PNG/800px-MphR-ermC-T7%28mphO%29-3WJdB.PNG | ||
+ | <br> Fig.1 Schematic overview of the genetic circuit. | ||
+ | <br><b><font size="3">Results</font></b> | ||
+ | <br>To verify the functionality of the biosensor, we performed a plate-reader experiment and measured optical density and fluorescence intensity every hour. We observed a correlation between concentration of antibiotics in the sample and intensity of fluorescent signal. | ||
+ | https://static.igem.org/mediawiki/parts/thumb/b/bd/Mphr-3wjdb%E2%91%A1.PNG/800px-Mphr-3wjdb%E2%91%A1.PNG | ||
+ | <br> The figure shows that our cuircuit can recognize different concentrations of erythromycin, and the fluorescence value was positively correlated with erythromycin concentration which proves that our part can Detect the concentration of erythromycin,and our reporter gene 3WJDB is surprisingly sensitive | ||
+ | <br> | ||
+ | <br> Reference:Alam Khalid K,Tawiah Kwaku D,Lichte Matthew F,Porciani David,Burke Donald H. A Fluorescent Split Aptamer for Visualizing RNA-RNA Assembly In Vivo.[J]. ACS synthetic biology,2017,6(9) | ||
+ | <br> | ||
<!-- --> | <!-- --> | ||
<span class='h3bb'>Sequence and Features</span> | <span class='h3bb'>Sequence and Features</span> |
Latest revision as of 17:39, 21 October 2021
mphR-ermC-T7(mphO)-3WJdB
Basic biosensor device for erythromycin detection.
Usage and Biology
The genetic circuit was composed of a coding sequence of erythromycin repressor and ermc genes which was inserted into an expression vectors with a consitive promoter(BBa_J23114) and RBS(BBa_K3777030), as well as 3WJdB(BBa_K3777000) under the control of T7 promoter (BBa_K3777006). The terminator we used were BBa_B0010 and BBa_M36305.(Fig 1)
When Ery was absent, TetR would bind to the inducible promoter(PI)and prevent RNA polymerase from initiating transcription, thus repressing the expression of reporter gene. If tet was present, TetR would no longer able to bind to the promoter, resulting in the expression of reporter gene.
We expressed this circuit in the E. coli BL21(DE3) cells for tetracycline detection. Thus we could roughly deduce the concentration of the antibiotics in the sample according to the fluorescence intensity.
Fig.1 Schematic overview of the genetic circuit.
Results
To verify the functionality of the biosensor, we performed a plate-reader experiment and measured optical density and fluorescence intensity every hour. We observed a correlation between concentration of antibiotics in the sample and intensity of fluorescent signal.
The figure shows that our cuircuit can recognize different concentrations of erythromycin, and the fluorescence value was positively correlated with erythromycin concentration which proves that our part can Detect the concentration of erythromycin,and our reporter gene 3WJDB is surprisingly sensitive
Reference:Alam Khalid K,Tawiah Kwaku D,Lichte Matthew F,Porciani David,Burke Donald H. A Fluorescent Split Aptamer for Visualizing RNA-RNA Assembly In Vivo.[J]. ACS synthetic biology,2017,6(9)
Sequence and Features
- 10COMPATIBLE WITH RFC[10]
- 12INCOMPATIBLE WITH RFC[12]Illegal NheI site found at 7
Illegal NheI site found at 30
Illegal NheI site found at 569
Illegal NheI site found at 1762 - 21INCOMPATIBLE WITH RFC[21]Illegal BamHI site found at 463
Illegal XhoI site found at 114 - 23COMPATIBLE WITH RFC[23]
- 25COMPATIBLE WITH RFC[25]
- 1000COMPATIBLE WITH RFC[1000]