Difference between revisions of "Part:BBa K3328050"
(One intermediate revision by the same user not shown) | |||
Line 7: | Line 7: | ||
===Design=== | ===Design=== | ||
In the NIMPLY gate, a deactivating RNA (INPUT A) uses direct hybridization or strand displacement to abolish trigger RNA (input B) activity. So when only the correct trigger RNA is expressed, the switch can be turned on. | In the NIMPLY gate, a deactivating RNA (INPUT A) uses direct hybridization or strand displacement to abolish trigger RNA (input B) activity. So when only the correct trigger RNA is expressed, the switch can be turned on. | ||
+ | |||
+ | https://2020.igem.org/wiki/images/thumb/8/87/T--OUC-China--design_lunbo_nimply.jpg/799px-T--OUC-China--design_lunbo_nimply.jpg | ||
===Result=== | ===Result=== | ||
https://2020.igem.org/wiki/images/thumb/1/1f/T--OUC-China--part_NIMPLY2.jpg/800px-T--OUC-China--part_NIMPLY2.jpg | https://2020.igem.org/wiki/images/thumb/1/1f/T--OUC-China--part_NIMPLY2.jpg/800px-T--OUC-China--part_NIMPLY2.jpg | ||
− | The left figure shows that when INPUT A=0, INPUT B=1, the fluorescence of GFP is high. And the fluorescence intensity of GFP was low in the other three groups. This corresponds to the situation described in the truth table on the right. INPUT A=1 means that aTc (0.25 mg/ | + | The left figure shows that when INPUT A=0, INPUT B=1, the fluorescence of GFP is high. And the fluorescence intensity of GFP was low in the other three groups. This corresponds to the situation described in the truth table on the right. INPUT A=1 means that aTc (0.25 mg/mL) is added, INPUT B=1 means that HSL (0.1 mg/mL) is added. Error bar: SD (n=9). |
Latest revision as of 12:46, 27 October 2020
switch of NIMPLY gate (NIMPLY2)
NIMPLY2 switch
Design
In the NIMPLY gate, a deactivating RNA (INPUT A) uses direct hybridization or strand displacement to abolish trigger RNA (input B) activity. So when only the correct trigger RNA is expressed, the switch can be turned on.
Result
The left figure shows that when INPUT A=0, INPUT B=1, the fluorescence of GFP is high. And the fluorescence intensity of GFP was low in the other three groups. This corresponds to the situation described in the truth table on the right. INPUT A=1 means that aTc (0.25 mg/mL) is added, INPUT B=1 means that HSL (0.1 mg/mL) is added. Error bar: SD (n=9).
Sequence and Features
Assembly Compatibility:
- 10COMPATIBLE WITH RFC[10]
- 12COMPATIBLE WITH RFC[12]
- 21COMPATIBLE WITH RFC[21]
- 23COMPATIBLE WITH RFC[23]
- 25COMPATIBLE WITH RFC[25]
- 1000COMPATIBLE WITH RFC[1000]