Difference between revisions of "Part:BBa K2753045"

 
 
(2 intermediate revisions by the same user not shown)
Line 5: Line 5:
 
A promoter
 
A promoter
  
 +
==Contribution: BNDS_China 2019==
 +
<div>
 +
<b>Group: BNDS_China iGEM 2019</b>
 +
<br>
 +
<b>Author: Wanji Li</b>
 +
<br>
 +
<b>Introduction & Design:</b>
 +
<br>
 +
 +
In order to determine the strength of this promoter at different temperature and glucose concentration, we constructed a plasmid with the expression of GFP as an indicator downstream the TEF1 promoter and measured its intensity of fluorescence. Additionally, we also constructed a plasmid with GFP only as a negative control.
 +
 +
<html>
 +
<div style="text-align:center";>
 +
<br>
 +
<img src="https://static.igem.org/mediawiki/parts/9/9d/T--BNDS_China--pTEF1_characterization.png" width=600px></br>
 +
<p style="width:600px; margin-left:150px; margin-bottom:60px;
 +
text-align:center
 +
"><em><strong>FIGURE 1</strong>(A) the intensity of fluorescence under different concentration of glucose in 30 degree Celsius; (B) the intensity of fluorescence under different concentration of glucose in 32 degree Celsius; (C) the intensity of fluorescence under different concentration of glucose in 34 degree Celsius; (D) the intensity of fluorescence under different concentration of glucose in 37 degree Celsius</em> </p>
 +
<br>
 +
</div>
 +
</html>
 
<!-- Add more about the biology of this part here
 
<!-- Add more about the biology of this part here
 
===Usage and Biology===
 
===Usage and Biology===

Latest revision as of 17:41, 21 October 2019


TEF1 promoter

A promoter

Contribution: BNDS_China 2019

Group: BNDS_China iGEM 2019
Author: Wanji Li
Introduction & Design:

In order to determine the strength of this promoter at different temperature and glucose concentration, we constructed a plasmid with the expression of GFP as an indicator downstream the TEF1 promoter and measured its intensity of fluorescence. Additionally, we also constructed a plasmid with GFP only as a negative control.



FIGURE 1(A) the intensity of fluorescence under different concentration of glucose in 30 degree Celsius; (B) the intensity of fluorescence under different concentration of glucose in 32 degree Celsius; (C) the intensity of fluorescence under different concentration of glucose in 34 degree Celsius; (D) the intensity of fluorescence under different concentration of glucose in 37 degree Celsius


Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    COMPATIBLE WITH RFC[1000]