Difference between revisions of "Help:Requesting Parts"

m
m
 
(77 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{HelpPage/MiniMap}}
+
[[Category:Part Pages]]
 
+
{{HelpPage/MainLinks}}
 +
{{HelpPage/GridCSS}}
 
<html>
 
<html>
 
<style type="text/css">
 
<style type="text/css">
.firstHeading {display: none;}
+
#mm-get img {opacity: 1}
#splash-title {margin-bottom: 5px; border: 0px solid #000; font-size: 20pt; font-weight: bold; color: #006633;}
+
.example { border: 1px solid #000;
 +
display: block;  
 +
width: 300px;
 +
margin-right: 20px;}
 +
.box img { display: block; margin: 15px auto; max-width: 100%; border: 2px solid #000;}
 +
.box {margin: 10px 0px; padding: 0px; border: 0px solid #000; display: block; padding: 5px; position: relative;}
 +
.box p {text-indent: 20px;}
 +
.box ul {margin-left: 5px;}
 +
.box ol  {margin-left: 5px;}
 +
.box li {margin-left: 20px;}
 +
.readmore {display: block; position: absolute; bottom: 5px; right: 5px;}
 +
.rounded {background-color: #f0f0f0; border: 1px solid #f0f0f0; -moz-border-radius: 5px; -khtml-border-radius: 5px; -webkit-border-radius: 5px; padding: 5px;}
 +
.anchorpad {padding-top: 80px; margin-top: -80px; display: inline-block;}
 
</style>
 
</style>
  
<table style="border: 0px solid #000; width: 100%">
 
<tr>
 
<td style="width: 100px; height: 100px;" rowspan="3"><img src="https://static.igem.org/mediawiki/parts/2/2d/HelpPage-RequestingParts.png">
 
</td>
 
<td  colspan="3">
 
<div id="splash-title">Requesting Parts</div>
 
</td>
 
</tr>
 
<tr>
 
<td colspan="3">
 
You've searched for and found a part you're interested in, and it has good quality control, but you've also found that it isn't available in your distribution kit. You can request that part by contacting iGEM HQ. Here's how!
 
</td>
 
</tr>
 
<tr>
 
<td><a href="https://parts.igem.org/Help:Quality_Control"><< Quality Control</a></td>
 
<td></td>
 
<td style="text-align: right;"><a href="https://parts.igem.org/Help:Using_Parts">Using Parts >></a></td>
 
</tr>
 
  
</table>
 
</html>
 
{{TOCright}}
 
The Registry community collection of parts has 7,000+ physical samples ([https://parts.igem.org/cgi/partsdb/Statistics.cgi and counting]) that are available to community of users. The DNA distributions typically contain about 1,000 physical samples. Therefore, not all the parts available through the Registry are available in your distribution kit. You may be interested in using a part that is not available in your distribution, or you may find that a part in your distribution may have an alternate source with better QC results. In cases like these feel free to make a request by sending an email to hq (at) igem . org.
 
  
<span style="color:red; font-weight:bold; font-size:115%;">Note:</span> You must have an iGEM account and be a member of a current iGEM team or lab group in order to obtain parts from the Registry.  If you would like to become an iGEM lab see '''[https://igem.org/Main_Page igem.org]''' for instructions.
 
  
 +
<div class="container_12">
 +
<div class="grid_9">
 +
</html>
 +
{{HelpPage/Updates/Requests}}
 +
<html>
 +
<br>
 +
<p>You have found an interesting part that is not available in your distribution, but there is a sequence confirmed sample available elsewhere in the Repository. If you are a member of a current iGEM team or iGEM lab, you can request it by contacting iGEM HQ. Here's how!</p>
 +
<p>If you have sent a request in to iGEM HQ, you can check on it through the <a href="https://parts.igem.org/Help:Requesting_Parts/Request_Status">request status page</a>.</p>
 +
</div>
 +
</div>
 +
<div class="grid_3">
 +
<div class="box rounded">
 +
<ol><b>Table of Contents:</b>
 +
<li><a href="#Part_Status">Check Part Status</a></li>
 +
<li><a href="#Get_This_Part">Locate a Sample</a></li>
 +
<li><a href="#Make_Request">Contact HQ</a></li>
 +
<li><a href="#Keep_in_Mind">Keep in Mind</a></li>
 +
<li><a href="#Shipping">Shipping</a></li>
 +
</ol>
 +
</div>
 +
</div>
 +
<div class="grid_12"><a name="Part_Status" class="anchorpad"></a>
 +
<div class="box">
 +
<h1>Step 1: Check Part Status</h1>
 +
<p>The <b>Part Status Box</b> appears in the top right of a part's page. It includes:</p>
 +
<ul>
 +
<li>the status of a part's sample(s): <i>Sample In Stock / Sample It's Complicated / Sample Not In Stock</i></li>
 +
<li>a link to the part's Get This Part page: where you can find the location of a sample in the current distribution, or in the Repository</li>
 +
</ul>
 +
</div>
 +
</div>
 +
<div class="grid_4">
 +
<div class="box rounded" style="height: 400px;">
 +
<h3>Sample In Stock</h3>
 +
<img src="https://static.igem.org/mediawiki/parts/0/04/Request-Ex-I6112-Sample-Status.png">
 +
<ul>
 +
<li>There is a <b>sequence confirmed or long part</b> sample in stock in the Repository</li>
 +
<li>It does <b>not</b> guarantee that the sample is available in the current distribution</li>
 +
<li>You can request a sample</li>
 +
</ul>
 +
</div>
 +
</div>
 +
<div class="grid_4">
 +
<div class="box rounded" style="height: 400px;">
 +
<h3>Sample It's Complicated</h3>
 +
<img src="https://static.igem.org/mediawiki/parts/3/3a/Request-Ex-K737025-Sample-Status.png"  width="152px">
 +
<ul>
 +
<li>There is a sample in stock in the Repository, but it is <b>not</b> sequence confirmed</li>
 +
<li>The sample may have poor quality control results (<b>Partially Confirmed, Single Error, Inconsistent, Bad Sequencing</b>) or no quality control information</li>
 +
<li>Samples that are Inconsistent <b>cannot</b> be requested from the Registry</li>
 +
</ul>
 +
</div>
 +
</div>
 +
<div class="grid_4">
 +
<div class="box rounded" style="height: 400px;">
 +
<h3>Sample Not In Stock</h3>
 +
<img src="https://static.igem.org/mediawiki/parts/9/91/Request-Ex-M39410-Sample-Status.png">
 +
<ul>
 +
<li>The Registry does not have a sample in stock</li>
 +
<li>This sample <b>cannot</b> be requested from the Registry</li>
 +
</ul>
 +
</div>
 +
</div>
 +
<div class="clear" style="margin-bottom: 30px;"></div>
 +
<div class="grid_12"><a name="Get_This_Part" class="anchorpad"></a>
 +
<div class="box">
 +
<h1>Step 2: Locate a sample</h1>
 +
<p>The <b>Get This Part</b> page is extremely useful when requesting a part sample. It will tell you:</p>
 +
<ul>
 +
<li>if your part sample is included in a current Distribution Kit (and its location, plasmid backbone, and sequence result)</li>
 +
<li>if there are other samples for the part in the Repository and their location</li>
 +
</ul>
 +
</div>
 +
</div>
 +
<div class="grid_12">
 +
<div class="box rounded">
 +
<h3>Sample Available in Distribution</h3>
 +
<img src="https://static.igem.org/mediawiki/parts/7/78/Request-Ex-C0040-In-Distro.png">
 +
<ul>
 +
<li>There is a sample in stock in the current distribution</li>
 +
<li>You can see its location, plasmid backbone, and the sequence result</li>
 +
<li>You can <a href="https://parts.igem.org/Help:2013_DNA_Distribution#DNA_Kit_Plate_Instructions">transform this part directly from your distribution kit</a>. <b>You don't have to request it!</b></li>
 +
</ul>
 +
</div>
 +
</div>
 +
<div class="grid_12">
 +
<div class="box rounded">
 +
<h3>No Sample Available in Distribution</h3>
 +
<img src="https://static.igem.org/mediawiki/parts/c/cc/Request-Ex-I6112-Not-In-Distro.png">
 +
<ul>
 +
<li>There is no sample available in the current distribution</li>
 +
<li>However, you can "<b>Show details for other locations</b>"</li>
 +
<li>There may be several different samples for the part</li>
 +
</ul>
 +
<h3 style="margin-top: 20px;">Show details for other locations</h3>
 +
<img src="https://static.igem.org/mediawiki/parts/1/1d/Request-Ex-I6112-Other-Location.png">
 +
<ul>
 +
<li>Many samples may not have quality control information</li>
 +
<li>However, be sure to look for samples that are <b>sequence confirmed</b></li>
 +
<li>If there is no confirmed sample, you can not request a sample</li>
 +
<li>Use this sample information to request your part</li>
 +
</ul>
 +
</div>
 +
</div>
 +
<div class="clear" style="margin-bottom: 30px;"></div>
 +
<div class="grid_12"><a name="Make_Request" class="anchorpad"></a>
 +
<div class="box">
 +
<h1>Step 3: Contact HQ</h1>
 +
<p>Use the sample information from the <b>Get This Part</b> page to request your part. Requests are currently made through email: <b><i>hq (at) igem (dot) org</i></b> Requesters <b>must</b> be part of a current iGEM Team or Lab.</p>
 +
<ul>Your request must follow this format:
 +
<li><b>Subject:</b> "Part Request: [Your Team/Lab's Name]."</li>
 +
<li><b>Part Name</b> (BBa...)</li>
 +
<li><b>Plasmid Backbone</b> (as documented on the Get This Part page)</li>
 +
<li><b>Sample Location:</b> source plate and well</li>
 +
<li><b>Quality Control Results:</b> sequence (the Registry will only send out Confirmed, Long Parts, Partially Confirmed) and gel results (if available)</li>
 +
</ul>
 +
<p>Please make sure that your request is not already in the current year's distribution.</p>
 +
<p>Once a request is made you should be contacted by iGEM HQ within two business days.</p>
 +
</div>
 +
</div>
 +
<div class="clear" style="margin-bottom: 30px;"></div>
 +
<div class="grid_12"><a name="Keep_in_Mind" class="anchorpad"></a>
 +
<div class="box">
 +
<h1>Keep in Mind!</h1>
 +
<ul>
 +
<li><b>Quality Control:</b> Many of the part samples available through the Registry have undergone quality control testing. Prior to requesting a part sample, take a look at this information, as it should affect your decision on using it. See the <a href="https://parts.igem.org/Help:Quality_Control">quality control help page</a> if you need help interpreting QC results on the "Get This Part" page. We will only send samples with sequencing results "Confirmed", "Partially Confirmed", "Long Part", and in some cases "Single error".</li>
 +
<li><b>Bundle Requests:</b> Prior to making a request it is helpful to consider all of the parts that the team needs for your project. We prefer bundling part requests together rather than receiving several small requests, as this cuts down shipping costs and improves efficiency. </li>
 +
<li><b>Large Orders:</b> Please note that we may deny unreasonably large orders, at our discretion.</li>
 +
<li><b>Response Time:</b> Once a request is made you should be contacted by iGEM HQ within two business days.</li>
 +
</ul>
 +
</div>
 +
</div>
 +
<div class="clear" style="margin-bottom: 30px;"></div>
 +
<div class="grid_12"><a name="Shipping" class="anchorpad"></a>
 +
<div class="box">
 +
<h1>Shipping Information</h1>
 +
</div>
 +
</div>
 +
<div class="grid_6">
 +
<div class="box rounded">
 +
<h3>Shipping Times</h3>
 +
<p>For shipments within the United States shipping times are generally no more than two days through UPS. For international shipments, shipping times through UPS can differ by a number of days depending on the receiver's address.</p>
 +
<p>A confirmation email with a tracking number for your shipment will be sent to you when your part request is ready to be shipped. You can then track the location of your shipment.</p>
 +
</div>
 +
</div>
 +
<div class="grid_6">
 +
<div class="box rounded">
 +
<h3>Plasmid mini-preps</h3>
 +
<ul>All requests are sent out as mini-prepped DNA. Please note that we can no longer send out part requests as agar stabs.
 +
<li>Each tube will contain at least 100ng of dried down mini-prepped plasmid DNA</li>
 +
<li><a href="https://parts.igem.org/Help:Protocols/Transformation">Transform the sample</a></li>
 +
<li><a href="https://parts.igem.org/Help:Using_Parts">Use the part!</a></li>
 +
</ul>
 +
</div>
 +
</div>
 +
</div>
  
==Is your part available?==
+
</html>
Not all the parts on the Registry are available for request. Some parts are in the planning stage, and have yet to be sent to the Registry. The easiest way to identify if a part is available would be to look at the part's status, located at the top right of the part's main page. We are '''only''' able to send out parts that are listed as '''Available'''.
+
<div style="text-align: center;">[[Image:DNA_Status_Available.png]]</div>
+
 
+
<span style="color:red; font-weight:bold; font-size:115%;">Note:</span> Parts with a DNA status of '''DNA Planning''' have not been physically sent to the Registry. Therefore these parts are not available for request.
+
 
+
 
+
==Making a Request==
+
When you have found an available part you would like to request you should click on the '''Get This Part''' link located in the top right corner of the part's main page. The "Get This Part" page will list various locations within the Registry for that part, and also include the QC information that part has gone through.
+
 
+
The '''Get This Part''' page is extremely useful when requesting a part. It will tell you:
+
* if your part is already included in your Distribution Kit
+
* various locations for the part in the Registry
+
* any QC information tied to the part and its source
+
 
+
 
+
You can use the following information to email a request to ''hq (at) igem . org''. The subject should be along the lines of "Part Request: [Your Team's Name]."
+
 
+
'''Be sure to include the following:'''
+
#iGEM team or lab name
+
#part name (BBa...)
+
#plasmid backbone and resistance
+
#source plate and well
+
 
+
+
===Things to keep in mind===
+
*Many of the part's available through the Registry have undergone quality control testing. Prior to requesting a part take a look at this information, as it should affect your decision on using the part. See [[Help:Using_the_online_QC_resources|here]] if you need help interpreting QC results on the "Get This Part" page.
+
 
+
*Prior to making a request it is helpful to consider all of the parts that the team needs for your project. We prefer bundling part requests together rather than receiving several small requests, as this cuts down shipping costs and improves efficiency.
+
 
+
*Once a request is made you should be contacted by iGEM HQ within two business days.
+
  
==Shipping Times==
 
For shipments within the United States shipping times are generally no more than two days through FedEx. For international shipments, shipping times through DHL can differ by a number of days depending on the receiver's address.
 
  
  
==Using agar stabs==
+
<!--
We send out our part requests as agar stabs. The shelf life of these are short, so it is usually best to plate from the stab as soon as possible.
+
{{HelpPage/GetUse/RelatedLinks}}
  
*The agar should already have a hole from when it was stabbed. With an inoculating loop dipped into the stab, you can plate directly onto a petri dish with the appropriate antibiotic.
+
{{HelpPage/Footer}}
*Incubate the dish overnight at 37C (14-16hr)
+
-->
*Pick a single colony to start up a culture
+

Latest revision as of 20:02, 26 May 2020

iGEM HQ and the iGEM Registry no longer prepares and ships part and component requests to teams and labs.
Information related to part and component requests on the Registry and other iGEM pages is either deprecated or kept for archival purposes.

We encourage our iGEM teams to use our sponsor synthesis offers to synthesize the samples you need, or to find them through the iGEM distribution kits, if available.


You have found an interesting part that is not available in your distribution, but there is a sequence confirmed sample available elsewhere in the Repository. If you are a member of a current iGEM team or iGEM lab, you can request it by contacting iGEM HQ. Here's how!

If you have sent a request in to iGEM HQ, you can check on it through the request status page.

Step 1: Check Part Status

The Part Status Box appears in the top right of a part's page. It includes:

  • the status of a part's sample(s): Sample In Stock / Sample It's Complicated / Sample Not In Stock
  • a link to the part's Get This Part page: where you can find the location of a sample in the current distribution, or in the Repository

Sample In Stock

  • There is a sequence confirmed or long part sample in stock in the Repository
  • It does not guarantee that the sample is available in the current distribution
  • You can request a sample

Sample It's Complicated

  • There is a sample in stock in the Repository, but it is not sequence confirmed
  • The sample may have poor quality control results (Partially Confirmed, Single Error, Inconsistent, Bad Sequencing) or no quality control information
  • Samples that are Inconsistent cannot be requested from the Registry

Sample Not In Stock

  • The Registry does not have a sample in stock
  • This sample cannot be requested from the Registry

Step 2: Locate a sample

The Get This Part page is extremely useful when requesting a part sample. It will tell you:

  • if your part sample is included in a current Distribution Kit (and its location, plasmid backbone, and sequence result)
  • if there are other samples for the part in the Repository and their location

Sample Available in Distribution

No Sample Available in Distribution

  • There is no sample available in the current distribution
  • However, you can "Show details for other locations"
  • There may be several different samples for the part

Show details for other locations

  • Many samples may not have quality control information
  • However, be sure to look for samples that are sequence confirmed
  • If there is no confirmed sample, you can not request a sample
  • Use this sample information to request your part

Step 3: Contact HQ

Use the sample information from the Get This Part page to request your part. Requests are currently made through email: hq (at) igem (dot) org Requesters must be part of a current iGEM Team or Lab.

    Your request must follow this format:
  • Subject: "Part Request: [Your Team/Lab's Name]."
  • Part Name (BBa...)
  • Plasmid Backbone (as documented on the Get This Part page)
  • Sample Location: source plate and well
  • Quality Control Results: sequence (the Registry will only send out Confirmed, Long Parts, Partially Confirmed) and gel results (if available)

Please make sure that your request is not already in the current year's distribution.

Once a request is made you should be contacted by iGEM HQ within two business days.

Keep in Mind!

  • Quality Control: Many of the part samples available through the Registry have undergone quality control testing. Prior to requesting a part sample, take a look at this information, as it should affect your decision on using it. See the quality control help page if you need help interpreting QC results on the "Get This Part" page. We will only send samples with sequencing results "Confirmed", "Partially Confirmed", "Long Part", and in some cases "Single error".
  • Bundle Requests: Prior to making a request it is helpful to consider all of the parts that the team needs for your project. We prefer bundling part requests together rather than receiving several small requests, as this cuts down shipping costs and improves efficiency.
  • Large Orders: Please note that we may deny unreasonably large orders, at our discretion.
  • Response Time: Once a request is made you should be contacted by iGEM HQ within two business days.

Shipping Information

Shipping Times

For shipments within the United States shipping times are generally no more than two days through UPS. For international shipments, shipping times through UPS can differ by a number of days depending on the receiver's address.

A confirmation email with a tracking number for your shipment will be sent to you when your part request is ready to be shipped. You can then track the location of your shipment.

Plasmid mini-preps

    All requests are sent out as mini-prepped DNA. Please note that we can no longer send out part requests as agar stabs.
  • Each tube will contain at least 100ng of dried down mini-prepped plasmid DNA
  • Transform the sample
  • Use the part!