Difference between revisions of "Part:BBa K389015:Experience"
(→Data Analysis) |
(→Data Analysis) |
||
Line 19: | Line 19: | ||
− | As seen above, at least one hour is needed to separate the induced luminescence signal from the uninduced, so ɸ<sub>I</sub> > 1. | + | As seen above, at least one hour is needed to separate the induced luminescence signal from the uninduced, so ɸ<sub>I</sub> > 1. Within a cultivation ɸ<sub>I</sub> is rising during the first hours and is decreasing after it reached a maximum at OD<sub>600</sub> ~ 1. This is shown in the following figure: |
+ | |||
+ | |||
+ | |||
+ | To measure the ratio of increasing promoteractivity by inducing the system ɸ<sub>I</sub> samples for analyzation should be taken at OD<sub>600</sub> ~ 1. | ||
====Protocols==== | ====Protocols==== |
Revision as of 13:02, 25 October 2010
This experience page is provided so that any user may enter their experience using this part.
Please enter
how you used this part and how it worked out.
Applications of BBa_K389015
Response time
The system needs at least one hour to show a measurable reaction to an induction with acetosyringone. In the following illustration the reaction of the system to induction with 200 µM acetosyringone in the exponential growth phase is shown. For a good separation of the induced system from the uninduced system at least two hours are needed.
Data Analysis
Because the luciferase accumulation is very different in different cultivations, the uninduced negative control was used as internal standard. To show the behaviour of the VirA/G signaling system when induced, the ratio ɸI between induced (i) and uninduced (u) relative luminescence unit (RLU) per OD600 is calculated:
As seen above, at least one hour is needed to separate the induced luminescence signal from the uninduced, so ɸI > 1. Within a cultivation ɸI is rising during the first hours and is decreasing after it reached a maximum at OD600 ~ 1. This is shown in the following figure:
To measure the ratio of increasing promoteractivity by inducing the system ɸI samples for analyzation should be taken at OD600 ~ 1.
Protocols
1. bla
User Reviews
UNIQf48f4176ee1c07cb-partinfo-00000001-QINU UNIQf48f4176ee1c07cb-partinfo-00000002-QINU