Difference between revisions of "Part:BBa K4814008"

Line 1: Line 1:
BBa_I712004 [caagtttgtacaaaaaagcaggctgccacc] BBa_K4814004 [0] BBa_K4814003 [0] BBa_E0020
+
B__NOTOC__
 +
<partinfo>BBa_K4814008 short</partinfo>
  
 
FRET is using fluorescent proteins as probes to detect the interaction of targeted proteins. The distance-dependent process transfers energy from an excited molecular fluorophore (the donor) to another fluorophore (the acceptor) through intermolecular long-range dipole–dipole coupling once the desired proteins bind (Sekar, R. B. and Periasamy, A., 2003). The critical Förster radius (typically 3-6 nm) at angstrom distances (10–100 Å) can be calculated to increase the accuracy and ensure precise energy transfer. (Alan Mulllan, n.d.) By using FRET, we can therefore observe the interaction of two proteins by measuring the lifetime of the fluorescent proteins attached to them.
 
FRET is using fluorescent proteins as probes to detect the interaction of targeted proteins. The distance-dependent process transfers energy from an excited molecular fluorophore (the donor) to another fluorophore (the acceptor) through intermolecular long-range dipole–dipole coupling once the desired proteins bind (Sekar, R. B. and Periasamy, A., 2003). The critical Förster radius (typically 3-6 nm) at angstrom distances (10–100 Å) can be calculated to increase the accuracy and ensure precise energy transfer. (Alan Mulllan, n.d.) By using FRET, we can therefore observe the interaction of two proteins by measuring the lifetime of the fluorescent proteins attached to them.

Revision as of 02:02, 29 September 2023

B ATRIP-ECFP

FRET is using fluorescent proteins as probes to detect the interaction of targeted proteins. The distance-dependent process transfers energy from an excited molecular fluorophore (the donor) to another fluorophore (the acceptor) through intermolecular long-range dipole–dipole coupling once the desired proteins bind (Sekar, R. B. and Periasamy, A., 2003). The critical Förster radius (typically 3-6 nm) at angstrom distances (10–100 Å) can be calculated to increase the accuracy and ensure precise energy transfer. (Alan Mulllan, n.d.) By using FRET, we can therefore observe the interaction of two proteins by measuring the lifetime of the fluorescent proteins attached to them.

As the aim of this design is to detect DNA damages in mammalian cells, we have used CMV promoter and the Lentivirus vector. Please refer to BBa_K4814004 and BBa_K4814005 (ATRIP and RPA1) for detailed explanation of the two proteins involved in the DNA damage checkpoint process. ATRIP-CFP is co-infected with RPA1-YFP to conduct FRET.

Sekar, R. B., & Periasamy, A. (2003). Fluorescence resonance energy transfer (FRET) microscopy imaging of live cell protein localizations. The Journal of cell biology, 160(5), 629–633. https://doi.org/10.1083/jcb.200210140

Alan Mulllan. (n.d.). Advanced microscopy applications – an overview of FRET. OXFORD instruments. https://andor.oxinst.com/learning/view/article/fret

Yang, T. T., Cheng, L., & Kain, S. R. (1996). Optimized codon usage and chromophore mutations provide enhanced sensitivity with the green fluorescent protein. Nucleic acids research, 24(22), 4592–4593. https://doi.org/10.1093/nar/24.22.4592

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    INCOMPATIBLE WITH RFC[1000]
    Illegal BsaI.rc site found at 1877
    Illegal BsaI.rc site found at 2065
    Illegal SapI site found at 2889