Difference between revisions of "Part:BBa K4438121:Experience"
Neha adarsh (Talk | contribs) |
Neha adarsh (Talk | contribs) |
||
Line 6: | Line 6: | ||
===Applications of BBa_K4438121=== | ===Applications of BBa_K4438121=== | ||
[[File:T--IISER-Tirupati_India--Fluroscence_miR-222_(30_min).png]] | [[File:T--IISER-Tirupati_India--Fluroscence_miR-222_(30_min).png]] | ||
− | |||
[[File:T--IISER-Tirupati_India--Fluroscence_miR_222_(1_hr).png]] | [[File:T--IISER-Tirupati_India--Fluroscence_miR_222_(1_hr).png]] | ||
− | + | Depicting fluorescence readout of FASTmiR-222-D2 after 30 mins and 1 hour incubation respectively.Control 1: DFHBI dye + buffer; Control 2: DFHBI dye + buffer + FASTmiR; Exp: DFHBI dye + buffer + FASTmiR + miDNA | |
+ | |||
+ | Explanation: After 30mins of incubation with 5X sensor buffer and dye, there was a dramatic shift in fluorescence intensity when the FASTmiR-222 sensor was increased in concentration. An average fold-change of 2.69 was observed after the addition of miDNA-222 throughout a range of DNA concentrations, with a maximum fold-change of 6.048 observed at a DNA concentration of 1 μM and a FASTmiR-222 concentration of 70 nM. | ||
+ | |||
+ | |||
+ | After 1 hour, an average fold-change of 3.07 was observed after the addition of miDNA-222 throughout a range of DNA concentrations, with a maximum fold-change of 7.423 observed at a DNA concentration of 1 μM and a FASTmiR-222 concentration of 70 nM. | ||
===User Reviews=== | ===User Reviews=== |
Latest revision as of 02:57, 14 October 2022
This experience page is provided so that any user may enter their experience using this part.
Please enter
how you used this part and how it worked out.
Applications of BBa_K4438121
Depicting fluorescence readout of FASTmiR-222-D2 after 30 mins and 1 hour incubation respectively.Control 1: DFHBI dye + buffer; Control 2: DFHBI dye + buffer + FASTmiR; Exp: DFHBI dye + buffer + FASTmiR + miDNA
Explanation: After 30mins of incubation with 5X sensor buffer and dye, there was a dramatic shift in fluorescence intensity when the FASTmiR-222 sensor was increased in concentration. An average fold-change of 2.69 was observed after the addition of miDNA-222 throughout a range of DNA concentrations, with a maximum fold-change of 6.048 observed at a DNA concentration of 1 μM and a FASTmiR-222 concentration of 70 nM.
After 1 hour, an average fold-change of 3.07 was observed after the addition of miDNA-222 throughout a range of DNA concentrations, with a maximum fold-change of 7.423 observed at a DNA concentration of 1 μM and a FASTmiR-222 concentration of 70 nM.
User Reviews
UNIQ273d0ba9b2750a43-partinfo-00000000-QINU UNIQ273d0ba9b2750a43-partinfo-00000001-QINU