Difference between revisions of "Part:BBa K4245200:Experience"

Line 11: Line 11:
 
<br>
 
<br>
 
By analyzing the results on the gel, our team concluded that a very long strand of DNA, likely the RCP, was produced. The gel exhibited a fluorescent band of DNA very close to the well, which indicates that a long strand of DNA, greater than 1 kB, was produced due to our reaction (see Fig. 1). As a result, we can infer that the RCA reaction allowed the creation of a really long DNA stand -- our RCP.  
 
By analyzing the results on the gel, our team concluded that a very long strand of DNA, likely the RCP, was produced. The gel exhibited a fluorescent band of DNA very close to the well, which indicates that a long strand of DNA, greater than 1 kB, was produced due to our reaction (see Fig. 1). As a result, we can infer that the RCA reaction allowed the creation of a really long DNA stand -- our RCP.  
 +
<br>
 +
<br>
 
<b>Lettuce with RCP</b>
 
<b>Lettuce with RCP</b>
 
<br>
 
<br>
 +
<br>
 
The RCP was also tested with the split lettuce aptamer. DFHBI-1T and the lettuce right and the modified lettuce left was added to the RCP, and the fluorescence was read on the plate reader.
 
The RCP was also tested with the split lettuce aptamer. DFHBI-1T and the lettuce right and the modified lettuce left was added to the RCP, and the fluorescence was read on the plate reader.
 
<br>
 
<br>

Revision as of 17:08, 13 October 2022


This experience page is provided so that any user may enter their experience using this part.
Please enter how you used this part and how it worked out.

Applications of BBa_K4245200

Lambert_GA 2022 Rolling Circle Transcription (RCA) was successful with this part. The products of RCA are long DNA strands composed of repeating complementary sequences of the used padlock probe. Therefore, one way in which the success of RCA can be determined is by running the rolling circle products (RCP) on an agarose gel. Since a fluorescent band very close to the wells would indicate the presence of an extremely long DNA strand, our RCP was run on a gel. The result was a really long DNA strand close to the well.

Figure 1. Image of gel ran with miRNA-1 RCP product.


By analyzing the results on the gel, our team concluded that a very long strand of DNA, likely the RCP, was produced. The gel exhibited a fluorescent band of DNA very close to the well, which indicates that a long strand of DNA, greater than 1 kB, was produced due to our reaction (see Fig. 1). As a result, we can infer that the RCA reaction allowed the creation of a really long DNA stand -- our RCP.

Lettuce with RCP

The RCP was also tested with the split lettuce aptamer. DFHBI-1T and the lettuce right and the modified lettuce left was added to the RCP, and the fluorescence was read on the plate reader.

Figure 2. Graph of split Lettuce reaction with RCP. The values represent the change in fluorescence before and after the reaction with DFHBI-1T took place.


As seen in Figure 2, the increase in fluorescence of the RCP + Lettuce + dye was significantly greater than the controls, which suggests that the split Lettuce was successfully bound to the RCP. In addition, the DFHBI-1T was also successfully bound within the split lettuce secondary folding. According to these results, RCA was successful, and the reaction between the split lettuce and RCP was successful as well.

Linear Probes with RCP

We use linear probes as a means to quantify and report the miRNAs that we sensed through rolling circle amplification (RCA) reactions. To go beyond verifying that are efficient means to do the aforementioned tasks through testing with complement of the linear probes, we wanted to confirm that they are able to quantify the miRNAs experimentally (see RCA Protocols)

Figure 3. Fluorescent Read of Rolling Circle Product for miRNA-133-3p and miRNA-1-3p

As shown by Figure 3, there is statistically significant decrease in the fluorescent output of a triplicate with FAM Probe, BHQ Probe, and RCP as compared to a triplicate of just FAM tagged Probes. This confirms that we did produce our desired RCP in the RCA reaction for our miRNA-1-3p and miRNA-133a-3p sensors and that this mechanism was an effective reporting method for our sensor.

Figure 4. Characterization curve for showing a negative logarithmic relationship between RFU from linear DNA probes and miRNA concentrations

In order to quantify the relationship between miRNA concentration and fluorescence, we further characterized these parts with varying linear probe complement concentrations. There is a negative logarithmic correlation between the complement concentrations and the relative fluorescence units (RFU) (see Fig. 3). Moreover, the data shown above closely parallels the predictive ordinary differential equation (ODE) model (see Fig. 4) correlating complement concentration to RFU see Model.Therefore, the overall data collected depicts an accurate relationship between the miRNA concentration and RFU, further validating that RCA coupled with linear probes are an effective and efficient means of quantifying miRNA concentrations.


Therefore, RCA created RCP that can be quantified by our chosen reporting mechanisms.



User Reviews

UNIQ9d86c76c92a9d34b-partinfo-00000000-QINU UNIQ9d86c76c92a9d34b-partinfo-00000001-QINU