Difference between revisions of "Part:BBa K4438104"
Neha adarsh (Talk | contribs) |
|||
(2 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
<partinfo>BBa_K4438104 short</partinfo> | <partinfo>BBa_K4438104 short</partinfo> | ||
− | FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. FASTmiR-222-D5, after transcription, binds to miR-222, the transcription product of | + | FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. FASTmiR-222-D5, after transcription, binds to miR-222, the transcription product of <partinfo>BBa_K4438150</partinfo>. The binding of these to RNAs will lead to the revelation of a binding site for DFHBI, a fluorophore, where it gets trapped and shows fluorescence. |
− | |||
===Usage and Biology=== | ===Usage and Biology=== | ||
− | This part can be used for the detection of miR-222, which proves to be a biomarker for many diseases. The ON | + | This part can be used for the detection of miR-222, which proves to be a biomarker for many diseases. The OFF(A) and ON(B) structure for the sensor was generated as given: |
− | [[File: | + | [[File:T--IISER-Tirupati_India--miRNA_222_5.png]] |
<!-- --> | <!-- --> |
Latest revision as of 10:53, 12 October 2022
FASTmiR222-D5
FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. FASTmiR-222-D5, after transcription, binds to miR-222, the transcription product of BBa_K4438150. The binding of these to RNAs will lead to the revelation of a binding site for DFHBI, a fluorophore, where it gets trapped and shows fluorescence.
Usage and Biology
This part can be used for the detection of miR-222, which proves to be a biomarker for many diseases. The OFF(A) and ON(B) structure for the sensor was generated as given:
Sequence and Features
- 10INCOMPATIBLE WITH RFC[10]Illegal SpeI site found at 47
- 12INCOMPATIBLE WITH RFC[12]Illegal SpeI site found at 47
- 21COMPATIBLE WITH RFC[21]
- 23INCOMPATIBLE WITH RFC[23]Illegal SpeI site found at 47
- 25INCOMPATIBLE WITH RFC[25]Illegal SpeI site found at 47
- 1000COMPATIBLE WITH RFC[1000]
References
Huang, K., Doyle, F., Wurz, Z. E., Tenenbaum, S. A., Hammond, R. K., Caplan, J. L., & Meyers, B. C. (2017). FASTmiR: an RNA-based sensor for in vitro quantification and live-cell localization of small RNAs. Nucleic acids research, 45(14), e130-e130