Difference between revisions of "Part:BBa K4438101"

Line 7: Line 7:
 
===Usage and Biology===
 
===Usage and Biology===
 
This part can be used for the detection of miR-222, which proves to be a biomarker for many diseases. The ON and OFF structure for the sensor was generated as given:
 
This part can be used for the detection of miR-222, which proves to be a biomarker for many diseases. The ON and OFF structure for the sensor was generated as given:
[[https://parts.igem.org/File:T--IISER-Tirupati_India--miRNA_222_2.png]]
+
[[File:T--IISER-Tirupati_India--miRNA_222_2.png]]
 
<!-- -->
 
<!-- -->
 
<span class='h3bb'>Sequence and Features</span>
 
<span class='h3bb'>Sequence and Features</span>

Revision as of 10:47, 12 October 2022


FASTmiR-222-D2

FASTmiR stands for Fluorescence Aptamer Sensor For Tracking miRNAs. It is an RNA-based sensor for in-vitro quantification of miRNAs. FASTmiR-222-D2, after transcription, binds to miR-222, the transcription product of BBa_K4438150. The binding of these to RNAs will lead to the revelation of a binding site for DFHBI, a fluorophore, where it gets trapped and shows fluorescence.

Usage and Biology

This part can be used for the detection of miR-222, which proves to be a biomarker for many diseases. The ON and OFF structure for the sensor was generated as given: T--IISER-Tirupati India--miRNA 222 2.png Sequence and Features


Assembly Compatibility:
  • 10
    INCOMPATIBLE WITH RFC[10]
    Illegal SpeI site found at 50
  • 12
    INCOMPATIBLE WITH RFC[12]
    Illegal SpeI site found at 50
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    INCOMPATIBLE WITH RFC[23]
    Illegal SpeI site found at 50
  • 25
    INCOMPATIBLE WITH RFC[25]
    Illegal SpeI site found at 50
  • 1000
    COMPATIBLE WITH RFC[1000]


References

Huang, K., Doyle, F., Wurz, Z. E., Tenenbaum, S. A., Hammond, R. K., Caplan, J. L., & Meyers, B. C. (2017). FASTmiR: an RNA-based sensor for in vitro quantification and live-cell localization of small RNAs. Nucleic acids research, 45(14), e130-e130