Difference between revisions of "Part:BBa K302032"

 
(2 intermediate revisions by 2 users not shown)
Line 2: Line 2:
 
<partinfo>BBa_K302032 short</partinfo>
 
<partinfo>BBa_K302032 short</partinfo>
  
Encodes the liable antitoxin to ''mazF'' in ''Bacillus Subtilis''. It is used in conjungtion with ''mazF'' in ''Bacillus Subtilis'' to provide a toxin-antitoxin in various stressful conditions. When transcribtion of both genes is turned off (as both are under contol of same promoter) ''mazE'' will be degraded faster than ''mazF''. There is then no inhibiton of ''mazF'', killing the cell.
+
Encodes the liable antitoxin to ''mazF'' in ''Bacillus Subtilis''. It is used in conjungtion with ''mazF'' in ''Bacillus Subtilis'' to provide a toxin-antitoxin kill switch in various stressful conditions. When expression of both genes is turned off (as both are under contol of same promoter) ''mazE'' will be degraded faster than ''mazF''. There is then no inhibiton of ''mazF'', killing the cell.
 +
 
 +
 
 +
<h2><strong>Characterization of mazE&mazF by team BUCT 2021:</strong></h2>
 +
<html>
 +
 
 +
We designed the part(BBa_K3875026) to characterize <i>mazE</i> and <i>mazF</i>.<br>
 +
<br>
 +
 
 +
<img src="https://static.igem.org/mediawiki/parts/f/f2/T—BUCT—4681.jpg "width="640px";height="30px"/><br>
 +
<br>
 +
<br>
 +
 
 +
We performed experiment to work our final genetic circuits and characterized <i>mazE</i>  and  <i>mazF</i>.
 +
This experiment consists of the four parts below:<br>
 +
 
 +
1.Obtain the <i>mazEF</i> gene and the phyb gene<br>
 +
 
 +
2.Build a gene expression vector<br>
 +
 
 +
3.Import the gene expression vector to detect the properties of engineered bacteria<br>
 +
<br>
 +
<br>
 +
<br>
 +
<b>1.Methods:</b>
 +
1.Design primers with a homologous arm, using pcr to obtain the target genes mazEF and phyb from <i>E. coli BW25113</i>, the pcr program is shown in the figure<br>
 +
<br>
 +
 
 +
Figure1.Pcr program:<br>
 +
<img src="https://static.igem.org/mediawiki/parts/6/69/T-buct-pcr_program.png"width="640px";height="30px"/><br>
 +
<br>
 +
<br>
 +
<br>
 +
 
 +
Figure. Obtain mazE and mazF gene:<br>
 +
<img src="https://static.igem.org/mediawiki/parts/7/75/T--BUCT%E2%80%94gel_22.png"width="640px";height="30px"/><br>
 +
<br>
 +
<br>
 +
<br>
 +
 
 +
2. Connecting five gene fragments using gibson assembly method<br>
 +
<br>
 +
Figure. Gibson program<br>
 +
<img src="https://static.igem.org/mediawiki/parts/5/5f/T-buct-Gibson_program.png"width="640px";height="30px"/><br>
 +
<br>
 +
<br>
 +
<br>
 +
 
 +
3. Verify the length of the expression vector
 +
Figure. Verify the length of the expression vector<br>
 +
<img src="https://static.igem.org/mediawiki/parts/d/d0/T-buct-Figure._Verify_the_length_of_the_expression_vector.png"width="640px";height="30px"/><br>
 +
<br>
 +
<br>
 +
<br>
 +
 
 +
Figure. Enzyme cut validation results <br>
 +
<img src="https://static.igem.org/mediawiki/parts/8/8e/T-buct-Enzyme_cut_validation_results.png"width="640px";height="30px"/><br>
 +
<br>
 +
<br>
 +
<br>
 +
 
 +
4.The expression carrier is imported into the <i>Nissle 1917</i> receptor state and cultured under oxygen-free conditions to culture 48h <br>
 +
 
 +
Figure .The engineered bacteria are cultured under oxygen-free conditions:<br>
 +
<img src="https://static.igem.org/mediawiki/parts/5/58/T—BUCT—teemperature.jpg "width="640px";height="30px"/><br>
 +
<br>
 +
<br>
 +
 
 +
5. Observe the results and verify them
 +
<br>
 +
<br>
 +
 
 +
<b>2. Results</b>
 +
Cultured 16h under aerobic conditions, no colonies were found to grow, which proved that there was no escape of engineering bacteria under aerobic conditions, which is in good compliance with the safety principle.  <br>
 +
 
 +
Figure.Aerobic conditions cultured 16h, engineering bacteria died:
 +
<img src="https://static.igem.org/mediawiki/parts/9/94/T—BUCT—oxggen-16.jpg "width="640px";height="30px"/><br>
 +
<br>
 +
 
 +
After constantly groping for reaction conditions, it was found that <i>Nissle 1917</i> grew very slowly in an oxygen-free environment, requiring 48-72h growth in order to see the obvious colony of the crucible in the aerobic air environment, it is not possible to observe obvious traces of engineering bacteria growth, which can indicate the success of the suicide system.<br>
 +
<br>
 +
 
 +
Figure. The culture contrast between aerobic environment and anaerobic environment:
 +
<img src="https://static.igem.org/mediawiki/parts/4/41/T—BUCT—oxggen-48.jpg "width="640px";height="30px"/><br>
 +
 
 +
</html>
  
 
<!-- Add more about the biology of this part here
 
<!-- Add more about the biology of this part here

Latest revision as of 15:10, 21 October 2021

mazE

Encodes the liable antitoxin to mazF in Bacillus Subtilis. It is used in conjungtion with mazF in Bacillus Subtilis to provide a toxin-antitoxin kill switch in various stressful conditions. When expression of both genes is turned off (as both are under contol of same promoter) mazE will be degraded faster than mazF. There is then no inhibiton of mazF, killing the cell.


Characterization of mazE&mazF by team BUCT 2021:

We designed the part(BBa_K3875026) to characterize mazE and mazF.




We performed experiment to work our final genetic circuits and characterized mazE  and  mazF. This experiment consists of the four parts below:
1.Obtain the mazEF gene and the phyb gene
2.Build a gene expression vector
3.Import the gene expression vector to detect the properties of engineered bacteria



1.Methods: 1.Design primers with a homologous arm, using pcr to obtain the target genes mazEF and phyb from E. coli BW25113, the pcr program is shown in the figure

Figure1.Pcr program:




Figure. Obtain mazE and mazF gene:




2. Connecting five gene fragments using gibson assembly method

Figure. Gibson program




3. Verify the length of the expression vector Figure. Verify the length of the expression vector




Figure. Enzyme cut validation results




4.The expression carrier is imported into the Nissle 1917 receptor state and cultured under oxygen-free conditions to culture 48h
Figure .The engineered bacteria are cultured under oxygen-free conditions:



5. Observe the results and verify them

2. Results Cultured 16h under aerobic conditions, no colonies were found to grow, which proved that there was no escape of engineering bacteria under aerobic conditions, which is in good compliance with the safety principle.
Figure.Aerobic conditions cultured 16h, engineering bacteria died:

After constantly groping for reaction conditions, it was found that Nissle 1917 grew very slowly in an oxygen-free environment, requiring 48-72h growth in order to see the obvious colony of the crucible in the aerobic air environment, it is not possible to observe obvious traces of engineering bacteria growth, which can indicate the success of the suicide system.

Figure. The culture contrast between aerobic environment and anaerobic environment:

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    INCOMPATIBLE WITH RFC[21]
    Illegal BamHI site found at 47
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    COMPATIBLE WITH RFC[1000]