Difference between revisions of "Part:BBa K3733046"
Jellycloud (Talk | contribs) |
|||
Line 7: | Line 7: | ||
− | |||
===Usage and Biology=== | ===Usage and Biology=== | ||
+ | <p>This is a composite part constructed to verify the effectiveness of the heat-inducible RNA thermometer. | ||
+ | </p> | ||
− | < | + | ===Functional Parameters=== |
− | < | + | <p> |
+ | We transformed this composite part into <i>E.coli</i> DH5α. We cultured both experimental group and control group at both 37 ℃ and 28 ℃ for 12 hours and detected RFU / OD<sub>600</sub> by a microplate reader. As the result shown in <b>Figure 1</b>, RFU / OD<sub>600</sub> data of the media at 37 ℃ are obviously higher than ones at 28 ℃, which could explain the RNA thermometer is valid. | ||
+ | </p> | ||
+ | |||
+ | <html> | ||
+ | <head> | ||
+ | <meta charset="utf-8"> | ||
+ | <title>无标题文档</title> | ||
+ | </head> | ||
+ | <body> | ||
+ | <center><img src="https://static.igem.org/mediawiki/parts/9/90/T--HZAU-China-T-ind-comp-1.png" style="width:500px;height:360px"></center> | ||
+ | <center><b>Figure 1. </b> RFU / OD<sub>600</sub> data of the media at 37 ℃ and 28 ℃(heat-inducible RNA thermosensors) </center> | ||
+ | <br> | ||
+ | </body> | ||
+ | </html> | ||
+ | |||
+ | ===Sequence and Features=== | ||
<partinfo>BBa_K3733046 SequenceAndFeatures</partinfo> | <partinfo>BBa_K3733046 SequenceAndFeatures</partinfo> | ||
Revision as of 18:00, 20 October 2021
RNA Thermometer(heat-inducible) test system
Use a constitutive promoter (BBa_J23110), RNA thermometer (BBa_K3247005), strong RBS (BBa_B0034), fluorescent protein neGFP (BBa_K3733012),and an artificial terminator (BBa_B1006). Will express high levels of fluorescent protein above 37 ℃. Source:Used a strong RBS to produce high levels of expression of the neGFP fluorescent protein.
Usage and Biology
This is a composite part constructed to verify the effectiveness of the heat-inducible RNA thermometer.
Functional Parameters
We transformed this composite part into E.coli DH5α. We cultured both experimental group and control group at both 37 ℃ and 28 ℃ for 12 hours and detected RFU / OD600 by a microplate reader. As the result shown in Figure 1, RFU / OD600 data of the media at 37 ℃ are obviously higher than ones at 28 ℃, which could explain the RNA thermometer is valid.
Sequence and Features
- 10COMPATIBLE WITH RFC[10]
- 12INCOMPATIBLE WITH RFC[12]Illegal NheI site found at 7
Illegal NheI site found at 30 - 21COMPATIBLE WITH RFC[21]
- 23COMPATIBLE WITH RFC[23]
- 25INCOMPATIBLE WITH RFC[25]Illegal AgeI site found at 158
Illegal AgeI site found at 281 - 1000COMPATIBLE WITH RFC[1000]