Difference between revisions of "Part:BBa K3328000:Experience"
(→Applications of BBa_K3328000) |
(→Applications of BBa_K3328000) |
||
Line 5: | Line 5: | ||
===Applications of BBa_K3328000=== | ===Applications of BBa_K3328000=== | ||
− | ==== | + | ====Lower Leakage and Higher ON/OFF Ratio==== |
+ | Our experiments were done with both the improved part (BBa_K3328000) and the original part (BBa_K2150031) as a control. Our part has lower leakage and higher ON/OFF ratio than the T7 promoter. | ||
+ | https://2020.igem.org/wiki/images/thumb/6/60/T--OUC-China--part_im_1.jpg/652px-T--OUC-China--part_im_1.jpg | ||
+ | |||
+ | In the blank control (IPTG=0 M), the fluorescence of T7 promoter (BBa_K2150031) is higher than 3WJ Switch1 (BBa_K3328000). This indicates that our part (BBa_K3328000) has the advantage of low leakage. When the inducer is added (IPTG=0.1 M), 3WJ Switch1 showed a high ON/OFF ratio of up to 15-fold, and the T7 promoter has the ON/OFF ratio of only 3-fold. | ||
+ | |||
+ | ====The OFF-switch==== | ||
https://2020.igem.org/wiki/images/thumb/c/c6/T--OUC-China--result_fig3.jpg/653px-T--OUC-China--result_fig3.jpg | https://2020.igem.org/wiki/images/thumb/c/c6/T--OUC-China--result_fig3.jpg/653px-T--OUC-China--result_fig3.jpg | ||
− | In the validation of 3WJ, as with toehold, we also set blank control (IPTG=0 M, aTc=0 mg/ | + | In the validation of 3WJ, as with toehold, we also set blank control (IPTG=0 M, aTc=0 mg/mL). Compared with the group without trigger expression (IPTG=0.1 M, aTc=0 mg/mL), the group with trigger expression (IPTG=0.1 M, aTc=0.25 mg/mL) showed inhibitory effect. Error bar: SD (n=9). |
https://2020.igem.org/wiki/images/thumb/3/31/T--OUC-China--result_fig4.jpg/768px-T--OUC-China--result_fig4.jpg | https://2020.igem.org/wiki/images/thumb/3/31/T--OUC-China--result_fig4.jpg/768px-T--OUC-China--result_fig4.jpg | ||
Crosstalk was determined by dividing the arithmetic mean of the GFP fluorescence from a given trigger switch pair by the arithmetic mean of the GFP fluorescence for the cognate trigger switch interaction. GFP fluorescence was measured from n=9 biologically independent samples. | Crosstalk was determined by dividing the arithmetic mean of the GFP fluorescence from a given trigger switch pair by the arithmetic mean of the GFP fluorescence for the cognate trigger switch interaction. GFP fluorescence was measured from n=9 biologically independent samples. | ||
− | |||
− | |||
==== NOT gate==== | ==== NOT gate==== | ||
− | |||
https://2020.igem.org/wiki/images/thumb/4/4b/T--OUC-China--result_fig7.jpg/800px-T--OUC-China--result_fig7.jpg | https://2020.igem.org/wiki/images/thumb/4/4b/T--OUC-China--result_fig7.jpg/800px-T--OUC-China--result_fig7.jpg | ||
− | The left figure shows that when INPUT=0, the fluorescence of GFP is high. And the fluorescence intensity of GFP was low when INPUT=1. This corresponds to the situation described in the truth table on the right. INPUT=1 means that aTc (0.25 mg/ | + | The left figure shows that when INPUT=0, the fluorescence of GFP is high. And the fluorescence intensity of GFP was low when INPUT=1. This corresponds to the situation described in the truth table on the right. INPUT=1 means that aTc (0.25 mg/mL) is added. Error bar: SD (n=9). |
==== IMPLY gate==== | ==== IMPLY gate==== | ||
+ | https://2020.igem.org/wiki/images/thumb/8/85/T--OUC-China--result_fig9.jpg/800px-T--OUC-China--result_fig9.jpg | ||
− | + | The left figure shows that when INPUT A=0, INPUT B=1, the fluorescence of GFP is low. And the fluorescence intensity of GFP was high in the other three groups. This corresponds to the situation described in the truth table on the right. INPUT A=1 means that aTc (0.25 mg/mL) is added, INPUT B=1 means that HSL (0.1 mg/mL) is added. Error bar: SD (n=9). | |
− | + | ||
− | + | ||
− | + | ||
− | The left figure shows that when INPUT A=0, INPUT B=1, the fluorescence of GFP is low. And the fluorescence intensity of GFP was high in the other three groups. This corresponds to the situation described in the truth table on the right. INPUT A=1 means that aTc (0.25 mg/ | + | |
===User Reviews=== | ===User Reviews=== |
Latest revision as of 08:21, 27 October 2020
This experience page is provided so that any user may enter their experience using this part.
Please enter
how you used this part and how it worked out.
Applications of BBa_K3328000
Lower Leakage and Higher ON/OFF Ratio
Our experiments were done with both the improved part (BBa_K3328000) and the original part (BBa_K2150031) as a control. Our part has lower leakage and higher ON/OFF ratio than the T7 promoter.
In the blank control (IPTG=0 M), the fluorescence of T7 promoter (BBa_K2150031) is higher than 3WJ Switch1 (BBa_K3328000). This indicates that our part (BBa_K3328000) has the advantage of low leakage. When the inducer is added (IPTG=0.1 M), 3WJ Switch1 showed a high ON/OFF ratio of up to 15-fold, and the T7 promoter has the ON/OFF ratio of only 3-fold.
The OFF-switch
In the validation of 3WJ, as with toehold, we also set blank control (IPTG=0 M, aTc=0 mg/mL). Compared with the group without trigger expression (IPTG=0.1 M, aTc=0 mg/mL), the group with trigger expression (IPTG=0.1 M, aTc=0.25 mg/mL) showed inhibitory effect. Error bar: SD (n=9).
Crosstalk was determined by dividing the arithmetic mean of the GFP fluorescence from a given trigger switch pair by the arithmetic mean of the GFP fluorescence for the cognate trigger switch interaction. GFP fluorescence was measured from n=9 biologically independent samples.
NOT gate
The left figure shows that when INPUT=0, the fluorescence of GFP is high. And the fluorescence intensity of GFP was low when INPUT=1. This corresponds to the situation described in the truth table on the right. INPUT=1 means that aTc (0.25 mg/mL) is added. Error bar: SD (n=9).
IMPLY gate
The left figure shows that when INPUT A=0, INPUT B=1, the fluorescence of GFP is low. And the fluorescence intensity of GFP was high in the other three groups. This corresponds to the situation described in the truth table on the right. INPUT A=1 means that aTc (0.25 mg/mL) is added, INPUT B=1 means that HSL (0.1 mg/mL) is added. Error bar: SD (n=9).
User Reviews
UNIQ3aa54e7dff5b6b52-partinfo-00000000-QINU UNIQ3aa54e7dff5b6b52-partinfo-00000001-QINU