Difference between revisions of "Part:BBa K3380151"

(Characterization)
Line 9: Line 9:
 
The DIR2s-Apt folding prediction as simulated by [http://www.nupack.org// NUPACK] is shown below.  
 
The DIR2s-Apt folding prediction as simulated by [http://www.nupack.org// NUPACK] is shown below.  
  
[[File:Part BBa K3380151.png|400px|iSpinach folding]]
+
[[File:Part BBa K3380151.png|400px|DIR2s-Apt folding]]
  
<!-- Add more about the biology of this part here
 
 
===Usage and Biology===
 
===Usage and Biology===
 +
It is usually used in live-cell imaging, however it can also be used in vitro. DIR2-Apt can be used for visualisation by gene fusion to the target of interest. Its fluorescent colour depends on the fluorophore it binds to. It can bind to DIR ( dimethylindole red) derivatives to give a red colour and OTB (oxazole thiazole blue) derivatives to give a blue colour. The emission spectra also depends on the bound fluorophore. The [https://pubs.acs.org/doi/full/10.1021/jacs.7b04211/ DIR-Pro]fluorophore has an excitation wavelength of 600 (nm) and an emission wavelength of 658 (nm). The  [https://pubs.acs.org/doi/full/10.1021/jacs.7b04211 OTB-SO3]fluorophore has an excitation wavelength of 380 (nm) and an emission wavelength of 421 (nm).
  
 
<!-- -->
 
<!-- -->

Revision as of 13:43, 8 October 2020


DIR2s-Apt fluorescent RNA aptamer

DIR2s-Apt is a fluorescent RNA aptamer comprising a short ribonucleotide sequence that exhibits fluorescence upon binding to a specific fluorophore.

Characterization

The DIR2s-Apt fluorescent RNA aptamer was described by Tan et al. (2017).

The DIR2s-Apt folding prediction as simulated by [http://www.nupack.org// NUPACK] is shown below.

DIR2s-Apt folding

Usage and Biology

It is usually used in live-cell imaging, however it can also be used in vitro. DIR2-Apt can be used for visualisation by gene fusion to the target of interest. Its fluorescent colour depends on the fluorophore it binds to. It can bind to DIR ( dimethylindole red) derivatives to give a red colour and OTB (oxazole thiazole blue) derivatives to give a blue colour. The emission spectra also depends on the bound fluorophore. The DIR-Profluorophore has an excitation wavelength of 600 (nm) and an emission wavelength of 658 (nm). The OTB-SO3fluorophore has an excitation wavelength of 380 (nm) and an emission wavelength of 421 (nm).

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    COMPATIBLE WITH RFC[1000]