Difference between revisions of "Part:BBa K2960000"
Aemetzloff (Talk | contribs) |
Aemetzloff (Talk | contribs) |
||
(22 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
<partinfo>BBa_K2960000 short</partinfo> | <partinfo>BBa_K2960000 short</partinfo> | ||
− | This aptamer was used to create a rapid colorimetric microcystin-detection sensor. Gold nanoparticles (AuNPs) were adsorbed onto the aptamer surface. Normally, in the presence of NaCl, AuNPs will aggregate, shifting the solution color from red to blue. | + | This aptamer was used to create a rapid colorimetric microcystin-detection sensor. Gold nanoparticles (AuNPs) were adsorbed onto the aptamer surface. Normally, in the presence of NaCl, AuNPs will aggregate, shifting the solution color from red to blue. Adsorption onto the aptamer prevents this from happening. However, in the presence of microcystin, the aptamer dissociates from the AuNPs. Thus, they will aggregate when induced by salt, resulting in a shift in the absorption spectra of the solution. We found there to be a log-linear decrease in the absorption at 320 nm. |
− | + | ||
+ | <html> | ||
+ | <img style = "height: 400px; width: 700px" src="https://2019.igem.org/wiki/images/a/a0/T--Cornell--Aptamer.png"></img><br> | ||
+ | </html> | ||
− | We have developed a detection system which uses the colorimetric properties of gold nanoparticles(AuNPs) as well as their interactions with ssDNA aptamers to simply and rapidly detect the concentration of microcystin-LR (MC-LR) with high sensitivity and specificity. Unlike other microcystin detection methods like enzyme-linked immunosorbent assay (ELISA) and high-performance liquid chromatography (HPLC), this system not only has a quick turnaround time, but also requires minimal specialized skill and equipment [1]. Accurate microcystin concentrations can be determined with little more than a spectrophotometer. | + | We have developed a detection system which uses the colorimetric properties of gold nanoparticles(AuNPs) as well as their interactions with ssDNA aptamers to simply and rapidly detect the concentration of microcystin-LR (MC-LR) with high sensitivity and specificity. Unlike other microcystin detection methods like enzyme-linked immunosorbent assay (ELISA) and high-performance liquid chromatography (HPLC), this system not only has a quick turnaround time, but also requires minimal specialized skill and equipment [1]. Accurate microcystin concentrations can be determined in 2 hours with little more than a spectrophotometer. |
The MC-LR specific aptamer used for the system is a 60 nucleotide long single stranded DNA aptamer (BBa_k2960000). These were conjugated with 10 nm AuNPs suspended in a citrate buffer. Citrate is a negatively charged ion that prevents the gold nanoparticles from aggregating into larger particles. | The MC-LR specific aptamer used for the system is a 60 nucleotide long single stranded DNA aptamer (BBa_k2960000). These were conjugated with 10 nm AuNPs suspended in a citrate buffer. Citrate is a negatively charged ion that prevents the gold nanoparticles from aggregating into larger particles. | ||
Line 17: | Line 19: | ||
In our system, we use sodium chloride with our DNA aptamer and AuNPs as was demonstrated by Li et al. [6]. When AuNPs are mixed with sodium chloride and aptamer, the negatively charged ssDNA aptamer binds to the AuNPs and provides charge shielding and prevents aggregation, preserving their red color. If there is microcystin present, the DNA aptamer will specifically prefer to bind to the microcystin, leaving the AuNP’s exposed to salt and allowing them to aggregate and change color. | In our system, we use sodium chloride with our DNA aptamer and AuNPs as was demonstrated by Li et al. [6]. When AuNPs are mixed with sodium chloride and aptamer, the negatively charged ssDNA aptamer binds to the AuNPs and provides charge shielding and prevents aggregation, preserving their red color. If there is microcystin present, the DNA aptamer will specifically prefer to bind to the microcystin, leaving the AuNP’s exposed to salt and allowing them to aggregate and change color. | ||
− | As shown by Li et al., the color change has a | + | As shown by Li et al., the color change has a measurable relationship with the concentration of microcystin-LR toxin (MC-LR) [6]. Our aptamer preferentially binds to MC-LR, so when a solution of MC-LR is introduced into the aptamer and AuNP solution, MC-LR outcompetes the AuNPs for binding to the aptamer. This removes the protection from the AuNPs, allowing them to aggregate. Unlike the rightward shift in peak absorbance described by Li et al., we observed instead a decrease in the absorbance for higher concentrations of microcystin, with little to no change in peak absorbance [6]. This may be because higher concentrations of microcystin increase AuNP aggregation and make them absorb less high energy wavelengths, as the solution turns violet. We plotted a standard curve, which also shows a linear relationship (Figure 1). We determined that the ideal wavelength at which to measure microcystin concentration is 520 nm (peak absorbance) since the differences at this wavelength showed the most linear relationship with microcystin concentration. |
− | + | <html> | |
− | + | <img style = "height: 300px; width: 400px" src="https://2019.igem.org/wiki/images/f/f9/T--Cornell--wet-lab-graph.png"></img><br> | |
+ | </html> | ||
<html> | <html> | ||
<img style = "height: 300px; width: 400px" src="https://2019.igem.org/wiki/images/0/01/T--Cornell--WetLab1.png"></img><br> | <img style = "height: 300px; width: 400px" src="https://2019.igem.org/wiki/images/0/01/T--Cornell--WetLab1.png"></img><br> | ||
</html> | </html> | ||
− | Figure 1. The plot on the top shows the standard curve for concentrations between 0 nM and 100 nM, typical concentrations of MC-LR found in the field. The log of concentration of microcystin is plotted on the x axis, with absorption at 520 nm plotted on the y axis. The linear relationship was best modeled by the equation log[ | + | Figure 1. The plot on the top shows the standard curve for concentrations between 0 nM and 100 nM, typical concentrations of MC-LR found in the field. The log of concentration of microcystin is plotted on the x axis, with absorption at 520 nm plotted on the y axis. The linear relationship was best modeled by the equation log[Absorbance] = -0.0076 * log[MC-LR(nm)] - 0.4171 where x is absorbance at 520 nm (R squared = 0.9854). The plot on the right shows the distinct absorption spectra for each concentration of microcystin. |
+ | |||
+ | |||
This system has a quick turnaround time, and microcystin concentration can be determined in about 2 hours. The nanoparticles incubate with the salt and aptamer for 15 minutes and then it all incubates with a sample for at least two hours, all at room temperature. Longer incubation times were tested and these tests showed that the steady state absorbance is reached by 2 hours of incubation, as shown in Figure 2. | This system has a quick turnaround time, and microcystin concentration can be determined in about 2 hours. The nanoparticles incubate with the salt and aptamer for 15 minutes and then it all incubates with a sample for at least two hours, all at room temperature. Longer incubation times were tested and these tests showed that the steady state absorbance is reached by 2 hours of incubation, as shown in Figure 2. | ||
Line 29: | Line 34: | ||
<html> | <html> | ||
− | + | <img style = "height: 400px; width: 530px" src="https://2019.igem.org/wiki/images/f/fd/T--Cornell--WetLab3.png"></img><br> | |
− | + | ||
− | + | ||
− | <img style = "height: 400px; width: | + | |
</html> | </html> | ||
Figure 2. Absorbance spectra taken 1 hour, 2 hours, and 4 hours after incubating the AuNP, aptamer, and salt solution with an MC-LR sample. | Figure 2. Absorbance spectra taken 1 hour, 2 hours, and 4 hours after incubating the AuNP, aptamer, and salt solution with an MC-LR sample. | ||
+ | |||
+ | |||
+ | |||
To test the specificity of the AuNP-Aptamer system, we analyzed tap water from Ithaca, New York, which is hard water that contains many ions and minerals, but no detectable levels of microcystin. Figure 3 shows that there is no difference in the system between very pure nuclease free water and tap water. This suggests that the specificity of our system for detecting MC-LR concentration is high, as other ions and minerals appear to have no effect on the affinity of the aptamer for the AuNPs. It also suggests that small amounts of other ions and minerals have little to no effect on the aggregation of the AuNPs. | To test the specificity of the AuNP-Aptamer system, we analyzed tap water from Ithaca, New York, which is hard water that contains many ions and minerals, but no detectable levels of microcystin. Figure 3 shows that there is no difference in the system between very pure nuclease free water and tap water. This suggests that the specificity of our system for detecting MC-LR concentration is high, as other ions and minerals appear to have no effect on the affinity of the aptamer for the AuNPs. It also suggests that small amounts of other ions and minerals have little to no effect on the aggregation of the AuNPs. | ||
+ | |||
<html> | <html> | ||
− | <img style = "height: | + | <img style = "height: 300px; width: 500px" src="https://2019.igem.org/wiki/images/b/b9/T--Cornell--WetLab4.png"></img><br> |
</html> | </html> | ||
Figure 3. The absorbance spectra of two AuNP, NaCl, and aptamer solutions. The one in blue contains molecular bio-grade nuclease-free water while the one in orange contains tap water. There is little difference if any between the two spectra, as the two appear overlayed. | Figure 3. The absorbance spectra of two AuNP, NaCl, and aptamer solutions. The one in blue contains molecular bio-grade nuclease-free water while the one in orange contains tap water. There is little difference if any between the two spectra, as the two appear overlayed. | ||
− | In order to maximize the sensitivity of the reHAB detection system, salt and aptamer concentrations were optimized for the range of MC-LR concentrations that may be present in harmful algal blooms, being between 0 nM and 1 µM [4,5]. The optimal aptamer and salt conditions were observed to be 2 µM and .5 M, respectively, as shown in Figures | + | |
+ | |||
+ | |||
+ | In order to maximize the sensitivity of the reHAB detection system, salt and aptamer concentrations were optimized for the range of MC-LR concentrations that may be present in harmful algal blooms, being between 0 nM and 1 µM [4,5]. The optimal aptamer and salt conditions were observed to be 2 µM and .5 M, respectively, as shown in Figures 4 and 5. | ||
As observable in Figure 4, as salt concentration decreases, the difference in the magnitude of the peak absorbance at 520 nm from adding MC-LR increases. This means that it appears as if our detection system is the most sensitive at low salt concentrations. It is worth mentioning that 1M, 2M, 3M, and 4M salt concentrations were tested together at 1 µM MC-LR, whereas .5M and 5M salt concentrations were tested separately from these other four at an MC-LR concentration of 0.1 µM. Following the trend observed above, one would expect that 0.5M NaCl produces the best sensitivity. It is clearly more sensitive than 5M NaCl. In comparing the sensitivity of our system with 0.5M NaCl with the concentrations of 1, 2, 3, and 4M NaCl, we can use some of the data from our standard curve to justify our pick of 0.5M NaCl as the most sensitive. According to our graph, the absorbance difference at 520 nm between 0 nM MC-LR and 0.1 µM for 0.5 M NaCl is 0.0246 OD. Because we have demonstrated that higher MC-LR concentration causes a more pronounced depression in our absorbance peak at 520 nm, it is reasonable to extrapolate that at MC-LR concentration of 1 µM will cause a much larger depression than the previously observed 0.1 µM. Therefore we decided on using 0.5 M NaCl. | As observable in Figure 4, as salt concentration decreases, the difference in the magnitude of the peak absorbance at 520 nm from adding MC-LR increases. This means that it appears as if our detection system is the most sensitive at low salt concentrations. It is worth mentioning that 1M, 2M, 3M, and 4M salt concentrations were tested together at 1 µM MC-LR, whereas .5M and 5M salt concentrations were tested separately from these other four at an MC-LR concentration of 0.1 µM. Following the trend observed above, one would expect that 0.5M NaCl produces the best sensitivity. It is clearly more sensitive than 5M NaCl. In comparing the sensitivity of our system with 0.5M NaCl with the concentrations of 1, 2, 3, and 4M NaCl, we can use some of the data from our standard curve to justify our pick of 0.5M NaCl as the most sensitive. According to our graph, the absorbance difference at 520 nm between 0 nM MC-LR and 0.1 µM for 0.5 M NaCl is 0.0246 OD. Because we have demonstrated that higher MC-LR concentration causes a more pronounced depression in our absorbance peak at 520 nm, it is reasonable to extrapolate that at MC-LR concentration of 1 µM will cause a much larger depression than the previously observed 0.1 µM. Therefore we decided on using 0.5 M NaCl. | ||
<html> | <html> | ||
− | <img style = "height: | + | <img style = "height: 500px; width: 440px" src="https://2019.igem.org/wiki/images/4/47/T--Cornell--WetLab5.png"></img><br> |
</html> | </html> | ||
Figure 4. Salt Optimization. As shown with 6 different concentrations of NaCl, the optimal concentration for determining the concentration of microcystin is 0.5 M NaCl, since it shows the largest difference in spectrum with and without microcystin. | Figure 4. Salt Optimization. As shown with 6 different concentrations of NaCl, the optimal concentration for determining the concentration of microcystin is 0.5 M NaCl, since it shows the largest difference in spectrum with and without microcystin. | ||
− | It was determined that the aptamer concentration made no consistent difference in detecting microcystins. Figure 5 is a series of graphs, each of which represent measurements for a different concentration of DNA aptamer: 2 µM, 20 µM, and 200 µM. Each demonstrate the absorbance values observed across a range of MC-LR concentrations. Note that the y-axis contains relative units which describe the difference in absorbance values before and after adding a sample of MC-LR | + | |
+ | |||
+ | |||
+ | It was determined that the aptamer concentration made no consistent difference in detecting microcystins. Figure 5 is a series of graphs, each of which represent measurements for a different concentration of DNA aptamer: 2 µM, 20 µM, and 200 µM. Each demonstrate the absorbance values observed across a range of MC-LR concentrations. Note that the y-axis contains relative units which describe the difference in absorbance values before and after adding a sample of MC-LR. Absorbance was measured across a 300-700 nm spectrum. There is a lack of consistent differences before and after adding microcystin due to increased aptamer concentration, so a lower concentration of 2 μM is used in our system. | ||
<html> | <html> | ||
− | <img style = "height: | + | <img style = "height: 200px; width: 900px" src="https://2019.igem.org/wiki/images/3/32/T--Cornell--WetLab6.png"></img><br> |
</html> | </html> | ||
Figure 5. Difference between before and after adding a sample containing either 0, 10, 100, or 1000 nM of MC-LR. Increasing concentration of aptamer (left to right) has no consistent effect on the spectra, so 2 μM solution of DNA aptamer was used. | Figure 5. Difference between before and after adding a sample containing either 0, 10, 100, or 1000 nM of MC-LR. Increasing concentration of aptamer (left to right) has no consistent effect on the spectra, so 2 μM solution of DNA aptamer was used. |
Latest revision as of 21:26, 21 October 2019
ssDNA aptamer which binds to microcystin-LR
This aptamer was used to create a rapid colorimetric microcystin-detection sensor. Gold nanoparticles (AuNPs) were adsorbed onto the aptamer surface. Normally, in the presence of NaCl, AuNPs will aggregate, shifting the solution color from red to blue. Adsorption onto the aptamer prevents this from happening. However, in the presence of microcystin, the aptamer dissociates from the AuNPs. Thus, they will aggregate when induced by salt, resulting in a shift in the absorption spectra of the solution. We found there to be a log-linear decrease in the absorption at 320 nm.
We have developed a detection system which uses the colorimetric properties of gold nanoparticles(AuNPs) as well as their interactions with ssDNA aptamers to simply and rapidly detect the concentration of microcystin-LR (MC-LR) with high sensitivity and specificity. Unlike other microcystin detection methods like enzyme-linked immunosorbent assay (ELISA) and high-performance liquid chromatography (HPLC), this system not only has a quick turnaround time, but also requires minimal specialized skill and equipment [1]. Accurate microcystin concentrations can be determined in 2 hours with little more than a spectrophotometer.
The MC-LR specific aptamer used for the system is a 60 nucleotide long single stranded DNA aptamer (BBa_k2960000). These were conjugated with 10 nm AuNPs suspended in a citrate buffer. Citrate is a negatively charged ion that prevents the gold nanoparticles from aggregating into larger particles.
Normally, gold nanoparticles with a diameter on the order of 10 nm are a deep red color; however, when exposed to an excess salt solution, the ions reduce the charge shielding that the citrate buffer provides and thus allows the AuNPs to aggregate into larger particles [3] whose light absorption properties are different due to surface plasmon resonance [2].
In our system, we use sodium chloride with our DNA aptamer and AuNPs as was demonstrated by Li et al. [6]. When AuNPs are mixed with sodium chloride and aptamer, the negatively charged ssDNA aptamer binds to the AuNPs and provides charge shielding and prevents aggregation, preserving their red color. If there is microcystin present, the DNA aptamer will specifically prefer to bind to the microcystin, leaving the AuNP’s exposed to salt and allowing them to aggregate and change color.
As shown by Li et al., the color change has a measurable relationship with the concentration of microcystin-LR toxin (MC-LR) [6]. Our aptamer preferentially binds to MC-LR, so when a solution of MC-LR is introduced into the aptamer and AuNP solution, MC-LR outcompetes the AuNPs for binding to the aptamer. This removes the protection from the AuNPs, allowing them to aggregate. Unlike the rightward shift in peak absorbance described by Li et al., we observed instead a decrease in the absorbance for higher concentrations of microcystin, with little to no change in peak absorbance [6]. This may be because higher concentrations of microcystin increase AuNP aggregation and make them absorb less high energy wavelengths, as the solution turns violet. We plotted a standard curve, which also shows a linear relationship (Figure 1). We determined that the ideal wavelength at which to measure microcystin concentration is 520 nm (peak absorbance) since the differences at this wavelength showed the most linear relationship with microcystin concentration.
Figure 1. The plot on the top shows the standard curve for concentrations between 0 nM and 100 nM, typical concentrations of MC-LR found in the field. The log of concentration of microcystin is plotted on the x axis, with absorption at 520 nm plotted on the y axis. The linear relationship was best modeled by the equation log[Absorbance] = -0.0076 * log[MC-LR(nm)] - 0.4171 where x is absorbance at 520 nm (R squared = 0.9854). The plot on the right shows the distinct absorption spectra for each concentration of microcystin.
This system has a quick turnaround time, and microcystin concentration can be determined in about 2 hours. The nanoparticles incubate with the salt and aptamer for 15 minutes and then it all incubates with a sample for at least two hours, all at room temperature. Longer incubation times were tested and these tests showed that the steady state absorbance is reached by 2 hours of incubation, as shown in Figure 2.
Figure 2. Absorbance spectra taken 1 hour, 2 hours, and 4 hours after incubating the AuNP, aptamer, and salt solution with an MC-LR sample.
To test the specificity of the AuNP-Aptamer system, we analyzed tap water from Ithaca, New York, which is hard water that contains many ions and minerals, but no detectable levels of microcystin. Figure 3 shows that there is no difference in the system between very pure nuclease free water and tap water. This suggests that the specificity of our system for detecting MC-LR concentration is high, as other ions and minerals appear to have no effect on the affinity of the aptamer for the AuNPs. It also suggests that small amounts of other ions and minerals have little to no effect on the aggregation of the AuNPs.
Figure 3. The absorbance spectra of two AuNP, NaCl, and aptamer solutions. The one in blue contains molecular bio-grade nuclease-free water while the one in orange contains tap water. There is little difference if any between the two spectra, as the two appear overlayed.
In order to maximize the sensitivity of the reHAB detection system, salt and aptamer concentrations were optimized for the range of MC-LR concentrations that may be present in harmful algal blooms, being between 0 nM and 1 µM [4,5]. The optimal aptamer and salt conditions were observed to be 2 µM and .5 M, respectively, as shown in Figures 4 and 5.
As observable in Figure 4, as salt concentration decreases, the difference in the magnitude of the peak absorbance at 520 nm from adding MC-LR increases. This means that it appears as if our detection system is the most sensitive at low salt concentrations. It is worth mentioning that 1M, 2M, 3M, and 4M salt concentrations were tested together at 1 µM MC-LR, whereas .5M and 5M salt concentrations were tested separately from these other four at an MC-LR concentration of 0.1 µM. Following the trend observed above, one would expect that 0.5M NaCl produces the best sensitivity. It is clearly more sensitive than 5M NaCl. In comparing the sensitivity of our system with 0.5M NaCl with the concentrations of 1, 2, 3, and 4M NaCl, we can use some of the data from our standard curve to justify our pick of 0.5M NaCl as the most sensitive. According to our graph, the absorbance difference at 520 nm between 0 nM MC-LR and 0.1 µM for 0.5 M NaCl is 0.0246 OD. Because we have demonstrated that higher MC-LR concentration causes a more pronounced depression in our absorbance peak at 520 nm, it is reasonable to extrapolate that at MC-LR concentration of 1 µM will cause a much larger depression than the previously observed 0.1 µM. Therefore we decided on using 0.5 M NaCl.
Figure 4. Salt Optimization. As shown with 6 different concentrations of NaCl, the optimal concentration for determining the concentration of microcystin is 0.5 M NaCl, since it shows the largest difference in spectrum with and without microcystin.
It was determined that the aptamer concentration made no consistent difference in detecting microcystins. Figure 5 is a series of graphs, each of which represent measurements for a different concentration of DNA aptamer: 2 µM, 20 µM, and 200 µM. Each demonstrate the absorbance values observed across a range of MC-LR concentrations. Note that the y-axis contains relative units which describe the difference in absorbance values before and after adding a sample of MC-LR. Absorbance was measured across a 300-700 nm spectrum. There is a lack of consistent differences before and after adding microcystin due to increased aptamer concentration, so a lower concentration of 2 μM is used in our system.
Figure 5. Difference between before and after adding a sample containing either 0, 10, 100, or 1000 nM of MC-LR. Increasing concentration of aptamer (left to right) has no consistent effect on the spectra, so 2 μM solution of DNA aptamer was used.
References:
1. Detection Methods for Cyanotoxins. (2019, August 12). Retrieved from https://www.epa.gov/ground-water-and-drinking-water/detection-methods-cyanotoxins.
2. Gold Nanoparticle Properties. (n.d.). Retrieved October 19, 2019, from http://www.cytodiagnostics.com/store/pc/viewcontent.asp?idpage=2.
3. Pamies, R., Cifre, J. G. H., Espín, V. F., Collado-González, M., Baños, F. G. D., & Torre, J. G. D. L. (2014). Aggregation behaviour of gold nanoparticles in saline aqueous media. Journal of Nanoparticle Research, 16(4). doi: 10.1007/s11051-014-2376-4
4. Turner, A., Dhanji-Rapkova, M., O’Neill, A., Coates, L., Lewis, A., & Lewis, K. (2018). Analysis of Microcystins in Cyanobacterial Blooms from Freshwater Bodies in England. Toxins, 10(1), 39. doi: 10.3390/toxins10010039
5. US Department of Commerce, Noaa, Great Lakes Environmental Research Laboratory, & Institute for Limnology and Ecosystems Research. (n.d.). Microcystin Guidelines. Retrieved October 19, 2019, from https://www.glerl.noaa.gov/res/HABs_and_Hypoxia/microcystinGuidelines.html.
6. Li, X., Cheng, R., Shi, H., Tang, B., Xiao, H., & Zhao, G. (2016). A simple highly sensitive and selective aptamer-based colorimetric sensor for environmental toxins microcystin-LR in water samples. Journal of Hazardous Materials, 304, 474–480. doi: 10.1016/j.jhazmat.2015.11.016
Sequence and Features
- 10COMPATIBLE WITH RFC[10]
- 12COMPATIBLE WITH RFC[12]
- 21COMPATIBLE WITH RFC[21]
- 23COMPATIBLE WITH RFC[23]
- 25COMPATIBLE WITH RFC[25]
- 1000COMPATIBLE WITH RFC[1000]