Difference between revisions of "Part:BBa K2548000"
Joycelalala (Talk | contribs) |
Joycelalala (Talk | contribs) |
||
Line 4: | Line 4: | ||
rhlR coding sequence. | rhlR coding sequence. | ||
+ | |||
+ | <h2> Construction of A. hydrophila Sensor Device I </h2> | ||
+ | https://static.igem.org/mediawiki/parts/thumb/e/e4/Sensordevice1.png/800px-Sensordevice1.png | ||
+ | |||
<h2> Characterization of Sensor Device I </h2> | <h2> Characterization of Sensor Device I </h2> | ||
Line 12: | Line 16: | ||
<p>However, when we compared the GFP production rate of Sensor Device I at different concentrations of C4-HSL, we found its fluorescence in the environment of fish feces might be too low, since the difference between GFP production rate at 0 M and 9.90E-8 M of C4-HSL was only 12.4%, implying that the device cannot tell people whether the fish is infected with <i>A. hydrophila</i> effectively.</p> | <p>However, when we compared the GFP production rate of Sensor Device I at different concentrations of C4-HSL, we found its fluorescence in the environment of fish feces might be too low, since the difference between GFP production rate at 0 M and 9.90E-8 M of C4-HSL was only 12.4%, implying that the device cannot tell people whether the fish is infected with <i>A. hydrophila</i> effectively.</p> | ||
− | + | [[Image: 1GFPxori.png|thumb|center|400px|Fig.1 GFP production rate of A. hydrophila sensor device I]]<br> | |
<h2>III. Problems with Sensor Device I</h2> | <h2>III. Problems with Sensor Device I</h2> |
Latest revision as of 21:11, 17 October 2018
constitutive promoter-rbs-rhlR-terminator
rhlR coding sequence.
Construction of A. hydrophila Sensor Device I
Characterization of Sensor Device I
After the device was assembled with RPG and transformed to E. coli DH5a, we performed C4-HSL Induction as introduced in Experiment XIII. The time-averaged GFP production rate during the fourth hour of induction was modeled by Hill Equation. Therefore, GFP production rate of the device when C4-HSL concentration is 9.90E-8 is:
However, when we compared the GFP production rate of Sensor Device I at different concentrations of C4-HSL, we found its fluorescence in the environment of fish feces might be too low, since the difference between GFP production rate at 0 M and 9.90E-8 M of C4-HSL was only 12.4%, implying that the device cannot tell people whether the fish is infected with A. hydrophila effectively.
III. Problems with Sensor Device I
To make the sensor workable in real environment, we intended to increase the difference between the device’s GFP production rates at 9.90E-8 M and 0 M of C4-HSL, but we didn’t know how to achieve it, since we thought the RBS we used (BBa_B0034) for GFP and RhlR expression was already the strongest and cannot be changed. Thus, we consulted Mr. Yihao Zhang from Peking University, and he pointed out our mistake: the strength of RBS can be influenced by the upstream and downstream DNA sequence, so we needed to use RBS calculator to determine the exact strength of the two RBSs in sensor device I. Following his advice, we examined our device on salislab.net, and found the RBS strength ratio of rhlR (LVA-tagged) and GFP was 1:5, indicating that the expression level of RhlR might be too low to repress and activate the expression of GFP in a desired level. Hence, we decided to improve the strength of RBS for rhlR (LVA-tagged).
Sequence and Features
- 10COMPATIBLE WITH RFC[10]
- 12INCOMPATIBLE WITH RFC[12]Illegal NheI site found at 7
Illegal NheI site found at 30 - 21INCOMPATIBLE WITH RFC[21]Illegal BamHI site found at 299
- 23COMPATIBLE WITH RFC[23]
- 25COMPATIBLE WITH RFC[25]
- 1000INCOMPATIBLE WITH RFC[1000]Illegal BsaI site found at 774