Difference between revisions of "Part:BBa K2729009"

 
Line 5: Line 5:
 
AmCyan is one of the existing violet fluorochromes for use in flow cytometers equipped with a violet (405 nm) laser. FMDV 2A is used widely for this purpose since multiple proteins can be coexpressed by linking open reading frames (ORFs) to form a single cistron.
 
AmCyan is one of the existing violet fluorochromes for use in flow cytometers equipped with a violet (405 nm) laser. FMDV 2A is used widely for this purpose since multiple proteins can be coexpressed by linking open reading frames (ORFs) to form a single cistron.
  
<!-- Add more about the biology of this part here
+
===Characterization===
===Usage and Biology===
+
  
<!-- -->
+
The sequence is optimized for <i>Homo Sapiens</i> using IDT Codon Optimization Tool. Our team checked the sequence length of synthesized oligo DNA and characterized it.
<span class='h3bb'>Sequence and Features</span>
+
<partinfo>BBa_K2729009 SequenceAndFeatures</partinfo>
+
  
 +
[[File:T--Tokyo_Tech--test-electrop.gif|thumb|left|300px| '''Figure 1:''' '''Result of the qualitative experiment''' - description comes here. ]]
  
<!-- Uncomment this to enable Functional Parameter display
+
<br>
===Functional Parameters===
+
As shown in Figure 1, the band comes between 900 bp to 1,000 bp.
<partinfo>BBa_K2729009 parameters</partinfo>
+
<br style="clear: both" />
<!-- -->
+
 
 +
===Analysis===
 +
 
 +
Our team successfully validated that the sequence was synthesized, and obtained enough amount of it for transfection.
 +
 
 +
===Sequence and Features===
 +
<partinfo>BBa_K2729009 SequenceAndFeatures</partinfo>

Revision as of 14:31, 16 October 2018


AmCyan_FMDV2a

AmCyan is one of the existing violet fluorochromes for use in flow cytometers equipped with a violet (405 nm) laser. FMDV 2A is used widely for this purpose since multiple proteins can be coexpressed by linking open reading frames (ORFs) to form a single cistron.

Characterization

The sequence is optimized for Homo Sapiens using IDT Codon Optimization Tool. Our team checked the sequence length of synthesized oligo DNA and characterized it.

Figure 1: Result of the qualitative experiment - description comes here.


As shown in Figure 1, the band comes between 900 bp to 1,000 bp.

Analysis

Our team successfully validated that the sequence was synthesized, and obtained enough amount of it for transfection.

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    COMPATIBLE WITH RFC[12]
  • 21
    INCOMPATIBLE WITH RFC[21]
    Illegal BglII site found at 43
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    INCOMPATIBLE WITH RFC[25]
    Illegal NgoMIV site found at 820
    Illegal AgeI site found at 669
  • 1000
    COMPATIBLE WITH RFC[1000]