Difference between revisions of "Part:BBa K847211:Experience"

 
(One intermediate revision by the same user not shown)
Line 4: Line 4:
 
how you used this part and how it worked out.
 
how you used this part and how it worked out.
  
===Applications of BBa_K847211===
 
 
{|width='80%' style='border:1px solid gray'
 
{|width='80%' style='border:1px solid gray'
 
|-
 
|-
 
|width='10%'|
 
|width='10%'|
<partinfo>BBa_K847211 AddReview number</partinfo>
+
 
 
<I>[http://2016.igem.org/Team:UT-Tokyo iGEM UT-Tokyo 2015]</I>
 
<I>[http://2016.igem.org/Team:UT-Tokyo iGEM UT-Tokyo 2015]</I>
 
|width='60%' valign='top'|
 
|width='60%' valign='top'|
Since the Pnrd available in the registry <partinfo>BBa_K847211</partinfo> is submitted in the RFC[25] standard, the part was redesigned in RFC[10].
+
Since <partinfo>BBa_K847211</partinfo> is submitted in the RFC[25] standard, we redesigned the part in RFC[10].
  
 
Reconstructed in the RFC[10] format, the Pnrd promoter was ligated in front of part BBa_E0240 and compared to the standard promoter BBa_J23101. The measurement was made approximately 4h after 100 fold dilution in M9 in a 5 min interval. For details of our characterisation, refer to our protocol.
 
Reconstructed in the RFC[10] format, the Pnrd promoter was ligated in front of part BBa_E0240 and compared to the standard promoter BBa_J23101. The measurement was made approximately 4h after 100 fold dilution in M9 in a 5 min interval. For details of our characterisation, refer to our protocol.

Latest revision as of 07:17, 25 October 2016


This experience page is provided so that any user may enter their experience using this part.
Please enter how you used this part and how it worked out.

[http://2016.igem.org/Team:UT-Tokyo iGEM UT-Tokyo 2015]

Since BBa_K847211 is submitted in the RFC[25] standard, we redesigned the part in RFC[10].

Reconstructed in the RFC[10] format, the Pnrd promoter was ligated in front of part BBa_E0240 and compared to the standard promoter BBa_J23101. The measurement was made approximately 4h after 100 fold dilution in M9 in a 5 min interval. For details of our characterisation, refer to our protocol.

Measurement of nrd Promoter Activity.The fluorescence from the Pnrd promoter is compared with that from the standard promoter BBa_J23101, 3 samples were measured every 9 minutes for each construct. Although there seems to be a slight sudden rise in the promoter activity from the 10-20th minute after the start of measurement, since the change in cell concentration could not be measured simultaneously with fluorescence, it is not certain whether the rise is influenced by the cell cycle/division.
;


User Reviews

UNIQ0a9f7f6318c32c90-partinfo-00000001-QINU UNIQ0a9f7f6318c32c90-partinfo-00000002-QINU