Difference between revisions of "Part:BBa K1106004:Experience"

(User Reviews)
(User Reviews)
 
(22 intermediate revisions by 2 users not shown)
Line 8: Line 8:
 
===User Reviews===
 
===User Reviews===
 
<!-- DON'T DELETE --><partinfo>BBa_K1106004 StartReviews</partinfo>
 
<!-- DON'T DELETE --><partinfo>BBa_K1106004 StartReviews</partinfo>
<!-- Template for a user review
+
<!-- Template for a user review-->
 
{|width='80%' style='border:1px solid gray'
 
{|width='80%' style='border:1px solid gray'
 
|-
 
|-
 
|width='10%'|
 
|width='10%'|
<partinfo>BBa_K1106004 AddReview number</partinfo>
+
<partinfo>BBa_K1106004 AddReview 5</partinfo>
<I>Username</I>
+
<I>HSiTAIWAN</I>
 
|width='60%' valign='top'|
 
|width='60%' valign='top'|
Enter the review inofrmation here.
+
 
|};
+
        <h2><strong>Detecting arsenic in Chinese medicine</strong></h2>
<!-- End of the user review template -->
+
 
 +
<h4>Objective</h4>
 +
<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Measure the E. coli fluorescence intensity in different arsenic concentration with 3μg/ml Chinese medicine.</p>
 +
 
 +
<h4>Methods</h4>
 +
<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Arsenic solution with different arsenic acid concentration (0, 1, 10, 50 and 100 ppm) is added into E. coli DH5α with Plasmids encoding GFP under arsenic promoter(part: BBa_K1106004).<br>
 +
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Fluorescence was measured at: <br>
 +
<ul>
 +
<li><em>Excitation peak: 485nm</em></li>
 +
<li><em>Emission peak: 538nm</em></li>
 +
<li><em>Auto cutoff: 515nm</em></li>
 +
</ul>
 +
every 30 minutes.
 +
 
 +
<h4>Results</h4>
 +
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;This part is still specific to arsenic in Chinese medicine, so we can apply it in Chinese medicine examination.
 +
 
 +
                <center>
 +
https://static.igem.org/mediawiki/parts/d/dc/2016hsitaiwanpart_arsenic_locorice.png
 +
                </center>
 +
<h4>Discussion</h4>
 +
        &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Since E. coli expresses stronger fluorescence in higher arsenic concentration, this is a relevant promoter to detect the existence and measure the amount of arsenic.
 +
|};
 +
<!-- End of the user review template -->
 +
 
 
<!-- DON'T DELETE --><partinfo>BBa_K1106004 EndReviews</partinfo>
 
<!-- DON'T DELETE --><partinfo>BBa_K1106004 EndReviews</partinfo>
 +
 +
{|width='80%' style='border:1px solid gray'
 +
|-
 +
|width='10%'|
 +
<partinfo>BBa_K1106004 AddReview 5</partinfo>
 +
<I>Igem BsAs 2013</I>
 +
|width='60%' valign='top'|
  
 
'''Objective'''
 
'''Objective'''
Line 28: Line 59:
 
'''Results'''
 
'''Results'''
 
As shown in the graphics below GFP production increases with the arsenite concentration.
 
As shown in the graphics below GFP production increases with the arsenite concentration.
 +
 +
'''Conclusion'''
 +
The promoter is sensitive to different arsenite concentrations.
  
 
https://static.igem.org/mediawiki/2013/9/96/Gfpinduccion.jpg
 
https://static.igem.org/mediawiki/2013/9/96/Gfpinduccion.jpg
Line 33: Line 67:
 
https://static.igem.org/mediawiki/2013/e/e3/Gfpampliacion2.jpg
 
https://static.igem.org/mediawiki/2013/e/e3/Gfpampliacion2.jpg
  
'''Conclusion'''
+
|};
The promoter is sensitive to different arsenite concentrations.
+

Latest revision as of 10:00, 24 September 2016

This experience page is provided so that any user may enter their experience using this part.
Please enter how you used this part and how it worked out.

Applications of BBa_K1106004

User Reviews

UNIQa7263696bea33ed4-partinfo-00000000-QINU

•••••

HSiTAIWAN

Detecting arsenic in Chinese medicine

Objective

     Measure the E. coli fluorescence intensity in different arsenic concentration with 3μg/ml Chinese medicine.

Methods

     Arsenic solution with different arsenic acid concentration (0, 1, 10, 50 and 100 ppm) is added into E. coli DH5α with Plasmids encoding GFP under arsenic promoter(part: BBa_K1106004).
     Fluorescence was measured at:

  • Excitation peak: 485nm
  • Emission peak: 538nm
  • Auto cutoff: 515nm

every 30 minutes.

Results

     This part is still specific to arsenic in Chinese medicine, so we can apply it in Chinese medicine examination.

2016hsitaiwanpart_arsenic_locorice.png

Discussion

     Since E. coli expresses stronger fluorescence in higher arsenic concentration, this is a relevant promoter to detect the existence and measure the amount of arsenic.

;

UNIQa7263696bea33ed4-partinfo-00000002-QINU

•••••

Igem BsAs 2013

Objective Characterize the response of the arsenite sensitive promoter measuring GFP production upon different arsenite concrentrations.

Methods Several cultures carrying a plasmid that encodes GFP under this promoter(Bba_K1106004) were grown overnight with different arsenite concentration (0, 10, 50, 500 and 1000 ppb). After sonication, fluorescence was measured at 395nm excitation peak and 515nm emission peak. Each measure was normalized by culture density (OD 600nm).

Results As shown in the graphics below GFP production increases with the arsenite concentration.

Conclusion The promoter is sensitive to different arsenite concentrations.

Gfpinduccion.jpg

Gfpampliacion2.jpg

;