Difference between revisions of "Part:BBa K1456001:Experience"

(tPA ASSAY)
 
(4 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
__NOTOC__
 
__NOTOC__
This experience page is provided so that any user may enter their experience using this part.<BR>Please enter
+
 
how you used this part and how it worked out.
+
==WESTERN BLOTTING==
<img src=https://static.igem.org/mediawiki/2014/thumb/a/a2/ATOMS-tpa_results1.png/565px-ATOMS-tpa_results1.png">
+
<center>[[File:ATOMS-tpa results9.jpg|400px|]]</center><br/>
 +
<li>The bands in the Western Blot were accurate. The transfection of the inserts were verified and assays of tPA were prepared from the lysates.
 +
<li>After having proven the presence of tPA expression in the cells transfected with Western Blotting, the concentration of the amount of tPA in the cell and the amount of secreted tPA were measured using the ‘Human tPA Activity Kit’ to show that the expressed proteins are functionally active.
 +
<li>The real parameter of the measurement in the Assay was the product of the reaction of the plasmin enzyme. Since tPA shifts the inactive plasminogen to active plasmine, the measured value also presents tPA activity. The yield gives absorbance at 405 nm.
 +
 
 +
==tPA ASSAY==
 +
<center>[[File:ATOMS-tpa results10.jpg|400px|]]</center><br/>
 +
 
 +
<li>According to the tPA assay results we obtained, we were able to prove that the tPA enzyme could be produced and secreted from the cell successfully hence also showing that tPA is functionally active.
 +
 
 
===Applications of BBa_K1456001===
 
===Applications of BBa_K1456001===
 +
 +
  
 
===User Reviews===
 
===User Reviews===

Latest revision as of 14:22, 21 October 2014


WESTERN BLOTTING

ATOMS-tpa results9.jpg

  • The bands in the Western Blot were accurate. The transfection of the inserts were verified and assays of tPA were prepared from the lysates.
  • After having proven the presence of tPA expression in the cells transfected with Western Blotting, the concentration of the amount of tPA in the cell and the amount of secreted tPA were measured using the ‘Human tPA Activity Kit’ to show that the expressed proteins are functionally active.
  • The real parameter of the measurement in the Assay was the product of the reaction of the plasmin enzyme. Since tPA shifts the inactive plasminogen to active plasmine, the measured value also presents tPA activity. The yield gives absorbance at 405 nm.

    tPA ASSAY

    ATOMS-tpa results10.jpg

  • According to the tPA assay results we obtained, we were able to prove that the tPA enzyme could be produced and secreted from the cell successfully hence also showing that tPA is functionally active.

    Applications of BBa_K1456001

    User Reviews

    UNIQ18cb9526a411e624-partinfo-00000000-QINU

    UNIQ18cb9526a411e624-partinfo-00000001-QINU