Difference between revisions of "Part:BBa K1316005"
Joanctd.igem (Talk | contribs) |
Joanctd.igem (Talk | contribs) |
||
(9 intermediate revisions by the same user not shown) | |||
Line 2: | Line 2: | ||
<partinfo>BBa_K1316005 short</partinfo> | <partinfo>BBa_K1316005 short</partinfo> | ||
− | Promoter of the ybiJ gene, which is activated by the presence of several nitrogen-based compounds such as 2,4,6-TNT, 2,4-DNT and 1,3-DNB. mKate2 is a far-red fluorescent protein used with reporting purposes. mKate2 codon usage is optimised for high expression in mammalian cells (humanised). It is, nevertheless, suitable for propagation in E. coli. This construct is, then, designed to be able to detect and quantify the presence of compunds such as 2,4,6-TNT, 2,4-DNT and 1,3-DNB. | + | <html> |
+ | <p> | ||
+ | Promoter of the <i>ybiJ</i> gene, which is activated by the presence of several nitrogen-based compounds such as 2,4,6-TNT, 2,4-DNT and 1,3-DNB. mKate2 is a far-red fluorescent protein used with reporting purposes. mKate2 codon usage is optimised for high expression in mammalian cells (humanised). It is, nevertheless, suitable for propagation in <i>E. coli</i>. This construct is, then, designed to be able to detect and quantify the presence of compunds such as 2,4,6-TNT, 2,4-DNT and 1,3-DNB. | ||
+ | |||
− | < | + | <h4> Plate Reader </h4> |
<p> | <p> | ||
− | + | A plate reader is a machine designed to handle samples on 6-1536 well format microtiter plates for the measuring of physical properties such as absorbance, fluorescence intensity, luminescence, time-resolved fluorescence, and fluorescence polarisation. Concerning this module, the plate reader device was used for the measurement of fluorescence intensity generated by cells carrying the BioBricks designed to detect land mines. The final protocol developed for Plate reader analysis for this module can be found by clicking on<a href="https://static.igem.org/mediawiki/2014/f/f4/Delft2014_PlatereaderLD.pdf"> this link</a>.</p> | |
− | + | </b> | |
+ | <br> | ||
+ | <h4> Results - Plate Reader </h4> | ||
+ | <p> | ||
+ | Using the different final Landmine detection constructs LD2-6, different concentrations of 2,4-DNT were tested (figure 1). 2,4-DNT, due to safety reasons, was bought in liquid solution dissolved in acetonitrile. To test that the compound triggering the response of the promoters is 2,4-DNT and not acetonitrile, the 0 mg/L 2,4-DNT solution was prepared with the same concentration of acetonitrile contained in the most concentrated 2,4-DNT solution. | ||
</p> | </p> | ||
+ | <br> | ||
+ | <p>The fact that the positive control (constitutively expressed mKate2) presents a clear fluorescence signal at 0 and 50 mg/L, but not at 100 mg/L indicates that high concentrations of 2,4-DNT are toxic for cells after several hours. The toxic compound seems to be 2,4-DNT and not acetonitrile because the sample at 0 mg/L 2,4-DNT (same acetonitrile concentration as the 100 mg/L 2,4-DNT sample) did not kill the cells. Constructs LD2, LD3 and LD6 as well as LD4 and LD5 with no induction of the N-genes show no clear mKate2 induction over time. Not many conclusions can be drawn form LD2 due to the big standard deviation. However, when the N-genes are induced with L-Rhamnose, the constructs LD4 and LD5 showed a clear increase in fluorescence over time for a concentration of 50 mg/L 2,4-DNT. In this situation, besides, LD5 seems to be more sensitive, as there is less leakage (there is less fluorescence signal at 0 mg/L DNT). | ||
+ | </p> | ||
+ | <br> | ||
<p> | <p> | ||
+ | It could still be that at 50 mg/L 2,4-DNT, what triggers the response of the promoters is actually the acetonitrile and not the 2,4-DNT, but that would be strange because at 0 mg/L 2,4-DNT (acetonitrile is 2 times more concentrated than at 50 mg/L 2,4-DNT) the cells survive and there is no fluorescence response. | ||
+ | </p> | ||
+ | <br> | ||
+ | |||
+ | <p> | ||
+ | This data suggests that both promoters, ybiJ and yqjF, respond to 2,4-DNT; and that the presence of the N-genes is of high importance for this response. Hence, we conclude that the two best BioBricks for Landmine detection are (in this order) LD5 (p[J] incl. N-enzymes) and LD4 (p[F] incl. N-enzymes), and in order to obtain a good result the N-genes must be expressed. | ||
+ | |||
+ | |||
+ | <figure> | ||
+ | <img src="https://static.igem.org/mediawiki/2014/b/bf/TUDelft_2014_Fluorescence_LD_final.png" width="100%" height="100%"> | ||
+ | <p> | ||
+ | <figcaption> | ||
+ | Figure 1: Fluorescence signal measured on the plate reader. Positive control: constitutively expressed mKate2. Negative control: Empty cells carrying no BioBrick | ||
+ | </figcaption> | ||
+ | </figure> | ||
− | |||
− | |||
</p> | </p> | ||
+ | <br> | ||
+ | |||
+ | |||
+ | For more information about the characterisation of this construct visit the <a href="http://2014.igem.org/Team:TU_Delft-Leiden/WetLab/landmine/characterisation"> <b> Landmine Detection module characterisation </b> </a> on our wiki page! | ||
+ | |||
+ | </p> | ||
+ | <br> | ||
+ | |||
+ | |||
+ | <h3> References </h3> | ||
+ | <p>[1] S. Yagur-Kroll, S. Belkin <i>et al.</i>, “<i>Escherichia Coli</i> bioreporters for the detection of 2,4-dinitrotoluene and 2,4,6-trinitrotoluene”, Appl. Microbiol. Biotechnol. 98, 885-895, 2014. </p> | ||
+ | <p> | ||
+ | |||
+ | |||
+ | |||
+ | </p> | ||
+ | </html> | ||
+ | |||
<p> | <p> |
Latest revision as of 21:34, 17 October 2014
ybiJ promoter coupled to mKate2 reporter gene
Promoter of the ybiJ gene, which is activated by the presence of several nitrogen-based compounds such as 2,4,6-TNT, 2,4-DNT and 1,3-DNB. mKate2 is a far-red fluorescent protein used with reporting purposes. mKate2 codon usage is optimised for high expression in mammalian cells (humanised). It is, nevertheless, suitable for propagation in E. coli. This construct is, then, designed to be able to detect and quantify the presence of compunds such as 2,4,6-TNT, 2,4-DNT and 1,3-DNB.
Plate Reader
A plate reader is a machine designed to handle samples on 6-1536 well format microtiter plates for the measuring of physical properties such as absorbance, fluorescence intensity, luminescence, time-resolved fluorescence, and fluorescence polarisation. Concerning this module, the plate reader device was used for the measurement of fluorescence intensity generated by cells carrying the BioBricks designed to detect land mines. The final protocol developed for Plate reader analysis for this module can be found by clicking on this link.
Results - Plate Reader
Using the different final Landmine detection constructs LD2-6, different concentrations of 2,4-DNT were tested (figure 1). 2,4-DNT, due to safety reasons, was bought in liquid solution dissolved in acetonitrile. To test that the compound triggering the response of the promoters is 2,4-DNT and not acetonitrile, the 0 mg/L 2,4-DNT solution was prepared with the same concentration of acetonitrile contained in the most concentrated 2,4-DNT solution.
The fact that the positive control (constitutively expressed mKate2) presents a clear fluorescence signal at 0 and 50 mg/L, but not at 100 mg/L indicates that high concentrations of 2,4-DNT are toxic for cells after several hours. The toxic compound seems to be 2,4-DNT and not acetonitrile because the sample at 0 mg/L 2,4-DNT (same acetonitrile concentration as the 100 mg/L 2,4-DNT sample) did not kill the cells. Constructs LD2, LD3 and LD6 as well as LD4 and LD5 with no induction of the N-genes show no clear mKate2 induction over time. Not many conclusions can be drawn form LD2 due to the big standard deviation. However, when the N-genes are induced with L-Rhamnose, the constructs LD4 and LD5 showed a clear increase in fluorescence over time for a concentration of 50 mg/L 2,4-DNT. In this situation, besides, LD5 seems to be more sensitive, as there is less leakage (there is less fluorescence signal at 0 mg/L DNT).
It could still be that at 50 mg/L 2,4-DNT, what triggers the response of the promoters is actually the acetonitrile and not the 2,4-DNT, but that would be strange because at 0 mg/L 2,4-DNT (acetonitrile is 2 times more concentrated than at 50 mg/L 2,4-DNT) the cells survive and there is no fluorescence response.
This data suggests that both promoters, ybiJ and yqjF, respond to 2,4-DNT; and that the presence of the N-genes is of high importance for this response. Hence, we conclude that the two best BioBricks for Landmine detection are (in this order) LD5 (p[J] incl. N-enzymes) and LD4 (p[F] incl. N-enzymes), and in order to obtain a good result the N-genes must be expressed.
For more information about the characterisation of this construct visit the Landmine Detection module characterisation on our wiki page!
References
[1] S. Yagur-Kroll, S. Belkin et al., “Escherichia Coli bioreporters for the detection of 2,4-dinitrotoluene and 2,4,6-trinitrotoluene”, Appl. Microbiol. Biotechnol. 98, 885-895, 2014.
Sequence and Features
- 10COMPATIBLE WITH RFC[10]
- 12COMPATIBLE WITH RFC[12]
- 21COMPATIBLE WITH RFC[21]
- 23COMPATIBLE WITH RFC[23]
- 25INCOMPATIBLE WITH RFC[25]Illegal AgeI site found at 381
- 1000INCOMPATIBLE WITH RFC[1000]Illegal BsaI.rc site found at 886
Illegal BsaI.rc site found at 1075