Difference between revisions of "Part:BBa K1031017"

Line 11: Line 11:
 
== '''Characteristic''' ==
 
== '''Characteristic''' ==
  
We constructed this circuit to test the inhibition effect of C1 repression circuit. It is composed of constitutive promoter <html><a href="https://parts.igem.org/Part:BBa_J23114">J23114</a></html>, Ribosome Binding Site <html><a href="https://parts.igem.org/Part:BBa_B0034">B0034</a></html>,RiboJ enzyme and transcriptional activator φR73δ.
+
We constructed this circuit to test the inhibition effect of CⅠ repression circuit. It is composed of constitutive promoter <html><a href="https://parts.igem.org/Part:BBa_J23114">J23114</a></html>, Ribosome Binding Site <html><a href="https://parts.igem.org/Part:BBa_B0034">B0034</a></html>,RiboJ enzyme and transcriptional activator φR73δ.
  
 
<html>
 
<html>
Line 33: Line 33:
 
== '''Usage in Band-pass Filter''' ==  
 
== '''Usage in Band-pass Filter''' ==  
  
This circuit is an assistant device aiming at testing the inhibition effect of C1 protein to hybrid promoter. We propose to adopt φR73δ to initiate constitutive expression of reporter sfGFP, thus construct a background with high fluorescence intensity. When C1 protein is expressed, the fluorescence intensity is supposed to go down if the inhibition circuit really works.
+
This circuit is an assistant device aiming at testing the inhibition effect of CⅠ protein to hybrid promoter. We propose to adopt φR73δ to initiate constitutive expression of reporter sfGFP, thus construct a background with high fluorescence intensity. When CⅠ protein is expressed, the fluorescence intensity is supposed to go down if the inhibition circuit really works.
  
 
<html>
 
<html>
 
<img src="https://static.igem.org/mediawiki/2013/thumb/8/8c/Peking2013_part_114-phiR73_with_inhibition_data.png/800px-Peking2013_part_114-phiR73_with_inhibition_data.png"
 
<img src="https://static.igem.org/mediawiki/2013/thumb/8/8c/Peking2013_part_114-phiR73_with_inhibition_data.png/800px-Peking2013_part_114-phiR73_with_inhibition_data.png"
 
style="width:800px; margin-left:80px" />
 
style="width:800px; margin-left:80px" />
<p style="text-align:center"><b>Fig 3</b> Usage of J23114-φR73δ circuit in Band-pass Filter. It is designed to construct a high fluorescence background level. Fluorescence intensity is tested when it is co-transformed with C1 inhibition circuit.  
+
<p style="text-align:center"><b>Fig 3</b> Usage of J23114-φR73δ circuit in Band-pass Filter. It is designed to construct a high fluorescence background level. Fluorescence intensity is tested when it is co-transformed with CⅠ inhibition circuit.  
 
</html>
 
</html>
  

Revision as of 10:32, 26 October 2013

J23114-B0034-RiboJ-φR73δ

For detailed information concerning Band-pass Filter, please visit 2013 Peking iGEM Band-pass Filter


Characteristic

We constructed this circuit to test the inhibition effect of CⅠ repression circuit. It is composed of constitutive promoter J23114, Ribosome Binding Site B0034,RiboJ enzyme and transcriptional activator φR73δ.

Fig 1 Construction of J23114-φR73δ circuit. The orange arrowhead stands for promoter J23114, the green oval represents RBS B0034, φR73δ shown in brown square.


Sequence and Features

Sequence and Features


Assembly Compatibility:
  • 10
    COMPATIBLE WITH RFC[10]
  • 12
    INCOMPATIBLE WITH RFC[12]
    Illegal NheI site found at 7
    Illegal NheI site found at 30
  • 21
    COMPATIBLE WITH RFC[21]
  • 23
    COMPATIBLE WITH RFC[23]
  • 25
    COMPATIBLE WITH RFC[25]
  • 1000
    COMPATIBLE WITH RFC[1000]



Usage in Band-pass Filter

This circuit is an assistant device aiming at testing the inhibition effect of CⅠ protein to hybrid promoter. We propose to adopt φR73δ to initiate constitutive expression of reporter sfGFP, thus construct a background with high fluorescence intensity. When CⅠ protein is expressed, the fluorescence intensity is supposed to go down if the inhibition circuit really works.

Fig 3 Usage of J23114-φR73δ circuit in Band-pass Filter. It is designed to construct a high fluorescence background level. Fluorescence intensity is tested when it is co-transformed with CⅠ inhibition circuit.