Difference between revisions of "Part:BBa K1031017"
Line 11: | Line 11: | ||
== '''Characteristic''' == | == '''Characteristic''' == | ||
− | We constructed this circuit to test the inhibition effect of | + | We constructed this circuit to test the inhibition effect of CⅠ repression circuit. It is composed of constitutive promoter <html><a href="https://parts.igem.org/Part:BBa_J23114">J23114</a></html>, Ribosome Binding Site <html><a href="https://parts.igem.org/Part:BBa_B0034">B0034</a></html>,RiboJ enzyme and transcriptional activator φR73δ. |
<html> | <html> | ||
Line 33: | Line 33: | ||
== '''Usage in Band-pass Filter''' == | == '''Usage in Band-pass Filter''' == | ||
− | This circuit is an assistant device aiming at testing the inhibition effect of | + | This circuit is an assistant device aiming at testing the inhibition effect of CⅠ protein to hybrid promoter. We propose to adopt φR73δ to initiate constitutive expression of reporter sfGFP, thus construct a background with high fluorescence intensity. When CⅠ protein is expressed, the fluorescence intensity is supposed to go down if the inhibition circuit really works. |
<html> | <html> | ||
<img src="https://static.igem.org/mediawiki/2013/thumb/8/8c/Peking2013_part_114-phiR73_with_inhibition_data.png/800px-Peking2013_part_114-phiR73_with_inhibition_data.png" | <img src="https://static.igem.org/mediawiki/2013/thumb/8/8c/Peking2013_part_114-phiR73_with_inhibition_data.png/800px-Peking2013_part_114-phiR73_with_inhibition_data.png" | ||
style="width:800px; margin-left:80px" /> | style="width:800px; margin-left:80px" /> | ||
− | <p style="text-align:center"><b>Fig 3</b> Usage of J23114-φR73δ circuit in Band-pass Filter. It is designed to construct a high fluorescence background level. Fluorescence intensity is tested when it is co-transformed with | + | <p style="text-align:center"><b>Fig 3</b> Usage of J23114-φR73δ circuit in Band-pass Filter. It is designed to construct a high fluorescence background level. Fluorescence intensity is tested when it is co-transformed with CⅠ inhibition circuit. |
</html> | </html> | ||
Revision as of 10:32, 26 October 2013
J23114-B0034-RiboJ-φR73δ
For detailed information concerning Band-pass Filter, please visit 2013 Peking iGEM Band-pass Filter
Characteristic
We constructed this circuit to test the inhibition effect of CⅠ repression circuit. It is composed of constitutive promoter J23114, Ribosome Binding Site B0034,RiboJ enzyme and transcriptional activator φR73δ.
Fig 1 Construction of J23114-φR73δ circuit. The orange arrowhead stands for promoter J23114, the green oval represents RBS B0034, φR73δ shown in brown square.
Sequence and Features
Sequence and Features
- 10COMPATIBLE WITH RFC[10]
- 12INCOMPATIBLE WITH RFC[12]Illegal NheI site found at 7
Illegal NheI site found at 30 - 21COMPATIBLE WITH RFC[21]
- 23COMPATIBLE WITH RFC[23]
- 25COMPATIBLE WITH RFC[25]
- 1000COMPATIBLE WITH RFC[1000]
Usage in Band-pass Filter
This circuit is an assistant device aiming at testing the inhibition effect of CⅠ protein to hybrid promoter. We propose to adopt φR73δ to initiate constitutive expression of reporter sfGFP, thus construct a background with high fluorescence intensity. When CⅠ protein is expressed, the fluorescence intensity is supposed to go down if the inhibition circuit really works.
Fig 3 Usage of J23114-φR73δ circuit in Band-pass Filter. It is designed to construct a high fluorescence background level. Fluorescence intensity is tested when it is co-transformed with CⅠ inhibition circuit.