Difference between revisions of "Part:BBa K1045002:Experience"
(→Microscope Data) |
(→Microscope Data) |
||
Line 14: | Line 14: | ||
As described on our [http://2013.igem.org/Team:Goettingen/Project Wiki], we designed a c-di-AMP sensing ''in vivo'' screening system in ''E. coli''. With this, we can screen for future antibiotic substances targeting the signal molecule c-di-AMP. | As described on our [http://2013.igem.org/Team:Goettingen/Project Wiki], we designed a c-di-AMP sensing ''in vivo'' screening system in ''E. coli''. With this, we can screen for future antibiotic substances targeting the signal molecule c-di-AMP. | ||
− | In order to do so, we combined the ''ydaO'' riboswitch fom ''B. subtilis'' with a CFP reporter. | + | In order to do so, we combined the ''ydaO'' riboswitch fom ''B. subtilis'' with a CFP reporter. ''E. coli'' cells transformed with this construct are shown in Fig. 1 as an overlay picture (CFP and Throughlight). To prove the function of our ''in vivo'' sensor for c-di-AMP, we grew our cells under different conditions. Without and with the signal nucleotide and a third condition with polyamines, which were supposed to enhance the uptake of c-di-AMP ('''Fig. 1'''). |
Since we see no difference between the conditions, we assume the ''B. subtilis'' promoter as part of the riboswitch to be so strong, that the amount of c-di-AMP entering the cells is just not enough to shut down expression of the reporter. | Since we see no difference between the conditions, we assume the ''B. subtilis'' promoter as part of the riboswitch to be so strong, that the amount of c-di-AMP entering the cells is just not enough to shut down expression of the reporter. | ||
Revision as of 18:31, 4 October 2013
This experience page is provided so that any user may enter their experience using this part.
Please enter
how you used this part and how it worked out.
Applications of BBa_K1045002
The Riboswitch Reporter System
Microscope Data
As described on our [http://2013.igem.org/Team:Goettingen/Project Wiki], we designed a c-di-AMP sensing in vivo screening system in E. coli. With this, we can screen for future antibiotic substances targeting the signal molecule c-di-AMP.
In order to do so, we combined the ydaO riboswitch fom B. subtilis with a CFP reporter. E. coli cells transformed with this construct are shown in Fig. 1 as an overlay picture (CFP and Throughlight). To prove the function of our in vivo sensor for c-di-AMP, we grew our cells under different conditions. Without and with the signal nucleotide and a third condition with polyamines, which were supposed to enhance the uptake of c-di-AMP (Fig. 1). Since we see no difference between the conditions, we assume the B. subtilis promoter as part of the riboswitch to be so strong, that the amount of c-di-AMP entering the cells is just not enough to shut down expression of the reporter.
In order to achieve termination of transcription (e.g. in order to use this biobrick as a "negative inductor"), we suggest our shorter version of the riboswitch (BBa_K1045005, the riboswitch without its native promoter) combined with a weaker promoter.
Platereader Data
We furthermore produced quantitative data characterizing the growth and the fluorescence over time of the BL21 E. colis we transformed with this construct.
The following graphs represent the results of two plate reader experiments performed to quantify the strength of the ydaO riboswitch construct. In this setup, a dilution series of c-di-AMP ranging from 0 to 10.000 nmol was used to test how strong the affinity of the riboswitch is. Shown are a growth curve recorded via the OD at 600 nm (Fig. 2), and the emission strength of CFP (Fig. 3), which expression is under the control of the ydaO riboswitch. In addition to the c-di-AMP, polyamines (1 µl/ml, 1000x stock solution) were added to series of samples to test if the uptake of c-di-AMP into E. coli could be enhanced by this additive. For each sample two biological and two technical replicates were made. The graphs show the mean values of the technical replicates of one of the biologicals. Experimental setup: total time 21 h; 15 min measurement interval; 37°C, medium shaking; 96-well titer plate; Synergy Mx Monochromator-Based Multi-Mode Microplate Reader; Gen5 V2.01
It was observed that the polyamines did not influence the uptake of c-di-AMP into the cells in one way or the other. The used concentrations of c-di-AMP had no measurable effect on the riboswitch either. The single riboswitch replicate, that shows lower fluorescence (highest concentration) could not be replicated. We assume this to be an artifact or a pipetting mistake. It is believed that even higher amounts of c-di-AMP are necessary to change the formation of the riboswitch. Due to time and financial issues, those hypotheses were not tested.
However, we have shown, that the cells express the CFP reporter over exponential and stationary phase under a promoter from B. subtilis ydaO gene. We also showed, that E. coli is not harmed or hindered in its growth, even under high concentrations of c-di-AMP, allowing it to be used in our screening system without the danger of killing our host.