Difference between revisions of "Part:BBa K1031911"
(→Orthogonality) |
(→Characterization of Biosensor) |
||
(4 intermediate revisions by the same user not shown) | |||
Line 78: | Line 78: | ||
<b>Dose-response curve to benzoate, salicylic acid and derivatives</b> | <b>Dose-response curve to benzoate, salicylic acid and derivatives</b> | ||
</br> | </br> | ||
− | Pm/J23114-XylS biosensor circuit was subjected to induction experiments with concentration of inducer ranging at 10 µM, 30µM,100µM, 300µM and 1000µM according to | + | <i>Pm</i>/J23114-XylS biosensor circuit was subjected to induction experiments with concentration of inducer ranging at 10 µM, 30µM,100µM, 300µM and 1000µM according to <a href="http://2013.igem.org/Team:Peking/Team/Notebook/Protocols#Content1">Test Protocol 1</a>. (<b>Fig.5</b>). |
</br> | </br> | ||
<img src="https://static.igem.org/mediawiki/2013/f/fd/Peking2013_XylS_Induce.png" style="width:800px;margin-left:60px" ></a> | <img src="https://static.igem.org/mediawiki/2013/f/fd/Peking2013_XylS_Induce.png" style="width:800px;margin-left:60px" ></a> | ||
Line 88: | Line 88: | ||
</html> | </html> | ||
− | == '''Orthogonality''' == | + | == '''Orthogonality of Different Sensor''' == |
<html><p> | <html><p> | ||
− | If the | + | If the presence of an inducer of biosensor A (not an inducer of biosensor B) doesn’t interfere with the dose response of biosensor B to any of its inducers, and vice versa, we call the B and A biosensors are "orthogonal"; namely, no synergistic/antagonistic effects happen between the inducers of A and B biosensors.(for more details, <a href="http://2013.igem.org/Team:Peking/Project/BioSensors/MulticomponentAnalysis">Chick Here</a>) |
</p></html> | </p></html> | ||
Line 118: | Line 118: | ||
<p style="text-align:center; position: relative; top: -100px;"> | <p style="text-align:center; position: relative; top: -100px;"> | ||
− | <B>Figure.6</B> Summary of the orthogonality | + | <B>Figure.6</B> Summary of the orthogonality assay to evaluate the synergistic/antagonistic effects between the inducers of 4 representative biosensors.</br> No synergistic or antagonistic effects between the inducers of 4 representative biosensors (XylS, NahR, HbpR, and DmpR) were observed. For instance, although the sensing profiles of NahR and XylS overlap to some extent, the NahR-specific and XylS-specific inducers proved to be really orthogonal. |
</p> | </p> | ||
<p style="position: relative; top: -80px;"> | <p style="position: relative; top: -80px;"> | ||
− | + | We have confirmed the orthogonality among inducers of different biosensors, which is one of the main features we expect for our aromatics-sensing toolkit; this allowed the combination of these biosensors to profile aromatics for the ease of practical applications. | |
</br> | </br> | ||
</p> | </p> | ||
Line 137: | Line 137: | ||
− | + | <html><p> | |
− | + | We examined the orthogonality between 4 representative biosensors (<b>Fig.7</b>). The orthogonality test between two biosensors, biosensor I and biosensor II, was performed in the following procedure: | |
− | + | </br></br> | |
− | + | 1. A typical inducer A for biosensor I and a typical inducer B for biosensor II were selected.<br/> | |
− | + | 2. The dose response of biosensor I to inducer A was measured, under the perturbation of inducer B.<br/> | |
− | + | 3. The dose-response of biosensor II to inducer B was measured, under the perturbation of inducer A. | |
− | + | </br></br> | |
− | + | If biosensor I and biosensor II are orthogonal, the dose response of biosensor I to inducer A should be constant, regardless of the concentrations of inducer B; and the dose response of biosensor II to inducer B should be constant, regardless of the concentrations of inducer A. Namely, for two "orthogonal" biosensors, the perturbation of an unrelated inducer has negligible effect on the dose response of a biosensor to its related inducer (<b>Fig.8</b>). | |
− | + | ||
− | < | + | |
<img src="https://static.igem.org/mediawiki/igem.org/4/45/Peking2013_MAFigure1.jpg" style="width:700px;margin-left:110px" ></a> | <img src="https://static.igem.org/mediawiki/igem.org/4/45/Peking2013_MAFigure1.jpg" style="width:700px;margin-left:110px" ></a> | ||
</html> | </html> | ||
Line 158: | Line 156: | ||
<html> | <html> | ||
− | |||
− | |||
− | |||
<img src="https://static.igem.org/mediawiki/igem.org/c/c7/Peking2013_Figure3ab.jpg" style="width:800px;margin-left:60px" ></a> | <img src="https://static.igem.org/mediawiki/igem.org/c/c7/Peking2013_Figure3ab.jpg" style="width:800px;margin-left:60px" ></a> | ||
Line 168: | Line 163: | ||
<html><p> | <html><p> | ||
− | The | + | The orthogonality between XylS, NahR, HbpR and DmpR biosensors have been carefully evaluated using the assay discussed above (<b>Fig.7</b>). The data were processed by linear fitting and the slopes of the fitting curves were compared with 1 (<b>Fig.7, Fig.8</b>). The closer the slope was to 1, the more orthogonal the two biosensors were. Results showed that the biosensor pairs, XylS and NahR (<b>Fig.9a, b</b>), XylS and HbpR (<b>Fig.9c, d</b>), NahR and HbpR (<b>Fig.9e, f</b>), XylS and DmpR (<b>Fig.9g, h</b>), NahR and DmpR (<b>Fig.9i, j</b>), and HbpR and DmpR (<b>Fig.9k, l</b>) are all orthogonal, as summarized in <b>Fig.6</b>. |
</p></html> | </p></html> | ||
Line 186: | Line 181: | ||
<html><p style="text-align:center"> | <html><p style="text-align:center"> | ||
− | <B>Figure. | + | <B>Figure.9</B> Linear fitting of the data obtained from the orthogonality assay showing that the orthogonality between the 4 representative biosensors. The experiments and data processing were performed as described in <b>Fig. 7</b> and <b>Fig. 8</b>.The black dashed line denotes slope=1 as the reference line. These fittings showed the orthogonality between biosensors, (<b>a, b</b>) XylS and NahR; (<b>c, d</b>) XylS and HbpR; (<b>e, f</b>) NahR and HbpR, (<b>g, h</b>) XylS and DmpR, (<b>i, j</b>) NahR and DmpR, and (<b>k, l</b>) HbpR and DmpR. The experiment data, linear fitting curves of biosensor, and cognate inducers are in different colors: XylS in red, NahR in green, HbpR in orange and DmpR in dark cyan. |
</p> | </p> | ||
</html> | </html> |
Latest revision as of 04:10, 28 September 2013
XylS-Terminator
Introduction
XylS is an archetype transcriptional activator of AraC/XylS family, mined from the TOL plasmid pWW0 of the bacterium Pseudomonas putida. It is composed of a C-terminal domain (CTD) involved in DNA binding, and an N-terminal domain required for effector binding and protein dimerization[1]. XylS detect benzoate and its’ derivatives, mainly methyl and chlorine substitution at 2-, 3- carbon[2].
Figure.1 Regulatory circuits controlled by XylS and XylR on the TOL plasmid pWW0[3]. Squares, XylS; circles, XylR; open symbol,s.transcriptional regulator without aromatic effector binding; closed symbols, effector-bound transcription factors that is in active form. See the main text for the detailed explanation for the regulatory loops[4].
.Promoter Structure
The cognate promoter regulated by XylS, Pm, is σ54- dependent in Pseudomonas putida; meanwhile in E.coli, it is σ70- dependent[5]. It acts as the master regulator to control the ON/OFF expression of meta-operon on TOL plasmid pWW0[3]. In this meta-operon, XylXYZLTEGFJQKIH genes encode enzymes for the degradation of benzoate and its derivatives, producing intermediate metabolites as carbon sources (Fig.1).
Mechanism
Figure.2 Mechanism of XylS binding to Pm promoter.
Mechanism of transcription activation by XylS at Pm promoter. Step 1: Free DNA. The -10/-35 consensus boxes of σ70-dependent promoter and the two XylS binding sites (D: distal; and P: proximal) are highlighted. The bending angle is supposed to be 35°, centered at XylS proximal binding site. Step 2: A first XylS monomer binds to Pm at the proximal site, shifts the bent center to the DNA sequence between the two XylS binding sites, and increases the bending angle to 50°. Step 3: This conformational change facilitates the binding of a second XylS monomer to the distal site, further increasing the DNA curvature to an overall value of 98°. Step 4: Contacts with RNAP, also probably with the σ-subunit, are established through the α-CTD of RNA polymerase, which dramatically facilitates the open complex formation and transcription initiation.
Tuning of Biosensor
Figure.3(a) Construction of biosensor circuit. (b) Using a library of constitutive promoters (Pc) to fine-tune the induction ratio of XylS biosensor. Horizontal axis stands for different XylS biosensor circuits with different Pc promoters. These Pc promoters are of different strength to control the expression of XylS. The relative expression strength of these constitutive promoters, J23113, J23109, J23114, J23105, J23106 are 21, 106, 256, 623, and 1185, respectively, according to the Partsregistry. Four kinds of aromatic compounds, namely BzO, 2-MxeBzO, 3-MeBzO and 4-MeBzO, shown with different color intensities, were tested following Test Protocol 1. Vertical axis represents the ON-OFF induction ratio. The Pm/XylS biosensor circuit adopting a weak Pc promoter J23114 performed best throughout the four inducers.
Related Part: 105-XylS-Terminator: https://parts.igem.org/Part:BBa_K1031912 109-XylS-Terminator: https://parts.igem.org/Part:BBa_K1031913 114-XylS-Terminator: https://parts.igem.org/Part:BBa_K1031916
Sequence and Features
- 10COMPATIBLE WITH RFC[10]
- 12COMPATIBLE WITH RFC[12]
- 21INCOMPATIBLE WITH RFC[21]Illegal BglII site found at 32
- 23COMPATIBLE WITH RFC[23]
- 25INCOMPATIBLE WITH RFC[25]Illegal NgoMIV site found at 754
- 1000INCOMPATIBLE WITH RFC[1000]Illegal BsaI.rc site found at 217
Characterization of Biosensor
ON/OFF test to 78 aromatic compounds
20 compounds showed apparent activation effect with the induction ratios over 20, they are listed as follows: BzO, 2-MeBzO, 3-MeBzO, 4-MeBzO, 2-FBzO, 4-FBzO, 2-ClBzO, 3-ClBzO, 4-ClBzO, 2-BrBzO, 4-BrBzO, 3-IBzO, 3-MeOBzO, SaA, 3-MeOSaA, 4-ClSaA, 5-ClSaA, 3-MeBAD, 3-ClTOL (Fig.4)
Figure.4 (a) The induction ratios of all 78 typical aromatic compounds in the ON/OFF test following Test Protocol 1. XylS biosensor could respond to 24 out of 78 aromatics with the induction ratio higher than 20, mainly benzoate, salicylic and their derivatives. (b) The aromatics-sensing profile of XylS biosensor is summarized from (a), highlighted in red in the aromatics spectrum. The structure formula of typical inducers are listed around the central spectrum, near their chemical formula.
Dose-response curve to benzoate, salicylic acid and derivatives
Pm/J23114-XylS biosensor circuit was subjected to induction experiments with concentration of inducer ranging at 10 µM, 30µM,100µM, 300µM and 1000µM according to Test Protocol 1. (Fig.5).
Figure.5 (a) Dose-response curves of XylS biosensor induced by benzoate and its derivatives. X-axis stands for concentration gradient of inducers at 10µM, 30µM, 100µM, 300µM and 1000µM. Different colors represent different kinds of inducers. Y-axis shows induction ratios. (b) Dose-response curves of XylS biosensor induced by salicylate and its derivatives. X-axis stands for concentration gradient of inducers at 10µM, 30µM, 100µM, 300µM and 1000µM. Y-axis denotes induction ratios. Different colors denote different kinds of inducers.
Orthogonality of Different Sensor
If the presence of an inducer of biosensor A (not an inducer of biosensor B) doesn’t interfere with the dose response of biosensor B to any of its inducers, and vice versa, we call the B and A biosensors are "orthogonal"; namely, no synergistic/antagonistic effects happen between the inducers of A and B biosensors.(for more details, Chick Here)
Sensor | Host | Main Inducers |
---|---|---|
XylS | Pseudomonas putida | BzO 2-MeBzO 3-MeBzO 2,3-MeBzO 3,4-MeBzO |
NahR | Pseudomonas putida | 4-MeSaA 4-C1SaA 5-C1SaA SaA Aspirin |
DmpR | Pseudomonas sp.600 | Phl 2-MePhl 3-MePhl 4-MePhl 2-ClPhl |
HbpR | Pseudomonas azelaica | o-Phenylphenol 2,6'-DiHydroxybiphenol |
Figure.6 Summary of the orthogonality assay to evaluate the synergistic/antagonistic effects between the inducers of 4 representative biosensors. No synergistic or antagonistic effects between the inducers of 4 representative biosensors (XylS, NahR, HbpR, and DmpR) were observed. For instance, although the sensing profiles of NahR and XylS overlap to some extent, the NahR-specific and XylS-specific inducers proved to be really orthogonal.
We have confirmed the orthogonality among inducers of different biosensors, which is one of the main features we expect for our aromatics-sensing toolkit; this allowed the combination of these biosensors to profile aromatics for the ease of practical applications.
Related Parts:
XylS: https://parts.igem.org/Part:BBa_K1031911 Wiki: http://2013.igem.org/Team:Peking/Project/BioSensors/XylS
NahR: https://parts.igem.org/Part:BBa_K1031610 Wiki: http://2013.igem.org/Team:Peking/Project/BioSensors/NahR
HbpR: https://parts.igem.org/Part:BBa_K1031300 Wiki: http://2013.igem.org/Team:Peking/Project/BioSensors/HbpR
DmpR: http://2013.igem.org/Team:Peking/Project/BioSensors/DmpR
We examined the orthogonality between 4 representative biosensors (Fig.7). The orthogonality test between two biosensors, biosensor I and biosensor II, was performed in the following procedure:
1. A typical inducer A for biosensor I and a typical inducer B for biosensor II were selected.
2. The dose response of biosensor I to inducer A was measured, under the perturbation of inducer B.
3. The dose-response of biosensor II to inducer B was measured, under the perturbation of inducer A.
If biosensor I and biosensor II are orthogonal, the dose response of biosensor I to inducer A should be constant, regardless of the concentrations of inducer B; and the dose response of biosensor II to inducer B should be constant, regardless of the concentrations of inducer A. Namely, for two "orthogonal" biosensors, the perturbation of an unrelated inducer has negligible effect on the dose response of a biosensor to its related inducer (Fig.8).
Figure.7 Orthogonality test assay for inducer A (detected by biosensor I) and inducer B (detected by biosensor II). (a) Biosensor I was added into the test assay. Different mixtures of inducers were added into lane 1, 2, and 3 respectively as listed above. Effect of inducer B upon the dose-response curve of inducer A was tested by comparing the fluorescence intensity of biosensor I among lane 1 ,2, and 3. (b) Biosensor II was added into the test assay. Different mixtures of inducers were added into lane 1, 2, and 3 respectively as listed above. Effect of inducer A upon the dose-response curve of inducer B was tested by comparing the fluorescence intensity of biosensor II among lane 1 ,2, and 3.
Figure.8 Correlation of the inducer B and the dose-response of biosensor I to its inducer A. Each point on the right plot represents a concentration of inducer A. It's x coordinate represents the fluorescence when inducer B is 0 and the y coordinate represents the fluorescence when the cell is exposed to a none-zero concentration of inducer B. If the dose-response of biosensor I is invariant to the concentration of inducer B, the x coordinate of a experimental point should be equal to its y coordinate and the experimental points are supposed to be aligned in a line whose slope is one.
The orthogonality between XylS, NahR, HbpR and DmpR biosensors have been carefully evaluated using the assay discussed above (Fig.7). The data were processed by linear fitting and the slopes of the fitting curves were compared with 1 (Fig.7, Fig.8). The closer the slope was to 1, the more orthogonal the two biosensors were. Results showed that the biosensor pairs, XylS and NahR (Fig.9a, b), XylS and HbpR (Fig.9c, d), NahR and HbpR (Fig.9e, f), XylS and DmpR (Fig.9g, h), NahR and DmpR (Fig.9i, j), and HbpR and DmpR (Fig.9k, l) are all orthogonal, as summarized in Fig.6.
Figure.9 Linear fitting of the data obtained from the orthogonality assay showing that the orthogonality between the 4 representative biosensors. The experiments and data processing were performed as described in Fig. 7 and Fig. 8.The black dashed line denotes slope=1 as the reference line. These fittings showed the orthogonality between biosensors, (a, b) XylS and NahR; (c, d) XylS and HbpR; (e, f) NahR and HbpR, (g, h) XylS and DmpR, (i, j) NahR and DmpR, and (k, l) HbpR and DmpR. The experiment data, linear fitting curves of biosensor, and cognate inducers are in different colors: XylS in red, NahR in green, HbpR in orange and DmpR in dark cyan.
Reference
[1] Kaldalu, N., Toots, U., de Lorenzo, V., & Ustav, M. (2000). Functional domains of the TOL plasmid transcription factor XylS. Journal of bacteriology, 182(4), 1118-1126.
[2] Ramos, J. L., Michan, C., Rojo, F., Dwyer, D., & Timmis, K. (1990). Signal-regulator interactions, genetic analysis of the effector binding site of xyls, the benzoate-activated positive regulator of Pseudomonas TOL plasmid meta-cleavage pathway operon. Journal of molecular biology, 211(2), 373-382.
[3] Ramos, J. L., Marqués, S., & Timmis, K. N. (1997). Transcriptional control of the Pseudomonas TOL plasmid catabolic operons is achieved through an interplay of host factors and plasmid-encoded regulators. Annual Reviews in Microbiology, 51(1), 341-373.
[4] Domínguez-Cuevas, P., Marín, P., Busby, S., Ramos, J. L., & Marqués, S. (2008). Roles of effectors in XylS-dependent transcription activation: intramolecular domain derepression and DNA binding. Journal of bacteriology, 190(9), 3118-3128.
[5] Kaldalu, N., Mandel, T., & Ustav, M. (1996). TOL plasmid transcription factor XylS binds specifically to the Pm operator sequence. Molecular microbiology,20(3), 569-579.