Difference between revisions of "Part:BBa K1106003:Experience"
Manugimenez (Talk | contribs) (→User Reviews) |
|||
Line 19: | Line 19: | ||
<!-- End of the user review template --> | <!-- End of the user review template --> | ||
<!-- DON'T DELETE --><partinfo>BBa_K1106003 EndReviews</partinfo> | <!-- DON'T DELETE --><partinfo>BBa_K1106003 EndReviews</partinfo> | ||
+ | |||
+ | |||
+ | |||
+ | {|width='80%' style='border:1px solid gray' | ||
+ | |- | ||
+ | |width='10%'| | ||
+ | <partinfo>BBa_K1106003 AddReview 5</partinfo> | ||
+ | <I>IgemBsAs 2013</I> | ||
+ | |width='60%' valign='top'| | ||
+ | |||
+ | '''Objective''' | ||
+ | |||
+ | Asess mRFP production, stability and naked eye discernibility range under inducible conditions. | ||
+ | |||
+ | '''General procedure''' | ||
+ | |||
+ | Different assays were performed using ''E. coli'' (DH5α strain) harbouring a plasmid that encodes mRFP under arsenite inducible promoter (ArsRFP culture). | ||
+ | |||
+ | |||
+ | |||
+ | === '''mRFP production at different arsenite concentrations''' === | ||
+ | |||
+ | '''Method''' | ||
+ | |||
+ | ArsRFP cultures were grown with different arsenite concentrations ( 0, 50, 200 and 1000ppb). 1ml aliquots were taken after 24 hours and fluorescence was measured. | ||
+ | |||
+ | '''Results''' | ||
+ | |||
+ | mRFP fluorescence increases with higher arsenite concentrations, in a sigmoidal way. | ||
+ | |||
+ | https://static.igem.org/mediawiki/2013/thumb/b/bd/Exp_Ine.jpg/600px-Exp_Ine.jpg | ||
+ | |||
+ | |||
+ | === '''mRFP production over time''' === | ||
+ | |||
+ | |||
+ | '''Method''' | ||
+ | |||
+ | A 100 ml ArsRFP culture was grown at 30°C until it reached OD=0.4 (OD 600nm). At this point arsenite was added (1000ppb final concentration) and fluorescence was measured every 30 minutes during 8 hours at 584 nm excitation peak and 608 nm emission peak. | ||
+ | |||
+ | '''Results''' | ||
+ | |||
+ | As shown in the figure below, mRFP production increses over time with arsenite (1000 ppb). However, there is a 3 hours lag after inoculation. | ||
+ | |||
+ | https://static.igem.org/mediawiki/2013/5/52/RFP_induccion.jpg | ||
+ | |||
+ | === '''mRFP stability over time''' === | ||
+ | |||
+ | '''Method''' | ||
+ | |||
+ | ArsRFP culture was grown overnight at 37ºC in 10 ml LB medium with 2000ppb arsenite concentration. The following day, the culture was centrifuged and the supernatant was discarded in order to remove the arsenite, thus stopping the induction. Afterwars, fresh LB medium was added and the pellet was resuspended. This was done twice and the culture was returned to 37ºC incubation. 1 ml of this culture was taken every 12 hours for the following 4 days. Finally, fluorescence was measured. | ||
+ | |||
+ | '''Results''' | ||
+ | |||
+ | mRFP degradation is shown over time, specially during the first 24 hours. | ||
+ | |||
+ | https://static.igem.org/mediawiki/2013/4/4e/RFP_santi.jpg | ||
+ | |||
+ | |||
+ | === '''Naked eye discernibility range of mRFP production by arsenite inducible promoter''' === | ||
+ | |||
+ | '''Method''' | ||
+ | |||
+ | ArsRFP cultures were grown with different arsenite concentrations ( 0, 10, 50, 200 and 1000ppb). 1ml aliquots were taken every 12 hours and centrifuged at 10.000rpm for 5 minutes. Pellets pictures were taken in order to compare the range of colour at naked eye. mRFP fluorescence was also measured with a fluorimeter at 484nm for excitation and 608 nm for emission. | ||
+ | |||
+ | '''Results''' | ||
+ | |||
+ | As it can be seen in the pictures below, a difference in the colour production can be clearly distinguished between different arsenite concentrations after 24 hours of induction and between the higher arsenite concentrations only. It can also be observed that over time the production grows and that after 62 hours the difference between 200 and 1000ppb is not clear. | ||
+ | |||
+ | |||
+ | {| class="wikitable" style="background-color:#fff;margin:auto;" | ||
+ | |+Induction over time at different concentrations of arsenite (ppb) | ||
+ | |- | ||
+ | |After 12 hours of induction: | ||
+ | https://static.igem.org/mediawiki/2013/thumb/4/44/T1rfp.jpg/400px-T1rfp.jpg | ||
+ | |- | ||
+ | |After 24 hours of induction: | ||
+ | https://static.igem.org/mediawiki/2013/thumb/d/d7/T2rfp2.jpg/400px-T2rfp2.jpg | ||
+ | |- | ||
+ | |After 36 hours of induction: | ||
+ | https://static.igem.org/mediawiki/2013/thumb/7/7e/T3rfp.jpg/400px-T3rfp.jpg | ||
+ | |- | ||
+ | |After 48 hours of induction: | ||
+ | https://static.igem.org/mediawiki/2013/thumb/2/26/T4%27rfp.jpg/400px-T4%27rfp.jpg | ||
+ | |- | ||
+ | |After 50 hours of induction: | ||
+ | https://static.igem.org/mediawiki/2013/thumb/3/35/T5rfp.jpg/400px-T5rfp.jpg | ||
+ | |- | ||
+ | |After 62 hours of induction: | ||
+ | https://static.igem.org/mediawiki/2013/thumb/4/4d/T6rfp.jpg/400px-T6rfp.jpg | ||
+ | |} | ||
+ | |||
+ | == '''Overall conclusions''' == | ||
+ | |||
+ | mRFP production responds efficiently under inducible conditions, both over time and different arsenite concentrations. The mRFP stability is acceptable for the aim of our Project. However, the visibility to the naked eye is not sufficient at low arsenite concentrations. | ||
+ | We reached to the conclusion that, in order to increase the colour production at lower arsenite concentrations, a signal amplification system has to be added. It could also be added some switch to stop the production and avoid saturation of all the samples, and thus keep the range of colour observable to the naked eye. | ||
+ | |||
+ | |}; |
Revision as of 23:17, 27 September 2013
This experience page is provided so that any user may enter their experience using this part.
Please enter
how you used this part and how it worked out.
Applications of BBa_K1106003
User Reviews
UNIQ0944ebf56ee32426-partinfo-00000000-QINU UNIQ0944ebf56ee32426-partinfo-00000001-QINU
•••••
IgemBsAs 2013 |
Objective Asess mRFP production, stability and naked eye discernibility range under inducible conditions. General procedure Different assays were performed using E. coli (DH5α strain) harbouring a plasmid that encodes mRFP under arsenite inducible promoter (ArsRFP culture).
mRFP production at different arsenite concentrationsMethod ArsRFP cultures were grown with different arsenite concentrations ( 0, 50, 200 and 1000ppb). 1ml aliquots were taken after 24 hours and fluorescence was measured. Results mRFP fluorescence increases with higher arsenite concentrations, in a sigmoidal way.
mRFP production over timeMethod A 100 ml ArsRFP culture was grown at 30°C until it reached OD=0.4 (OD 600nm). At this point arsenite was added (1000ppb final concentration) and fluorescence was measured every 30 minutes during 8 hours at 584 nm excitation peak and 608 nm emission peak. Results As shown in the figure below, mRFP production increses over time with arsenite (1000 ppb). However, there is a 3 hours lag after inoculation.
mRFP stability over timeMethod ArsRFP culture was grown overnight at 37ºC in 10 ml LB medium with 2000ppb arsenite concentration. The following day, the culture was centrifuged and the supernatant was discarded in order to remove the arsenite, thus stopping the induction. Afterwars, fresh LB medium was added and the pellet was resuspended. This was done twice and the culture was returned to 37ºC incubation. 1 ml of this culture was taken every 12 hours for the following 4 days. Finally, fluorescence was measured. Results mRFP degradation is shown over time, specially during the first 24 hours.
Naked eye discernibility range of mRFP production by arsenite inducible promoterMethod ArsRFP cultures were grown with different arsenite concentrations ( 0, 10, 50, 200 and 1000ppb). 1ml aliquots were taken every 12 hours and centrifuged at 10.000rpm for 5 minutes. Pellets pictures were taken in order to compare the range of colour at naked eye. mRFP fluorescence was also measured with a fluorimeter at 484nm for excitation and 608 nm for emission. Results As it can be seen in the pictures below, a difference in the colour production can be clearly distinguished between different arsenite concentrations after 24 hours of induction and between the higher arsenite concentrations only. It can also be observed that over time the production grows and that after 62 hours the difference between 200 and 1000ppb is not clear.
Overall conclusionsmRFP production responds efficiently under inducible conditions, both over time and different arsenite concentrations. The mRFP stability is acceptable for the aim of our Project. However, the visibility to the naked eye is not sufficient at low arsenite concentrations. We reached to the conclusion that, in order to increase the colour production at lower arsenite concentrations, a signal amplification system has to be added. It could also be added some switch to stop the production and avoid saturation of all the samples, and thus keep the range of colour observable to the naked eye. |