Difference between revisions of "Part:BBa K784001:Experience"

(Applications of BBa_K784001)
Line 1: Line 1:
__NOTOC__
 
This experience page is provided so that any user may enter their experience using this part.<BR>Please enter
 
how you used this part and how it worked out.
 
 
 
===Applications of BBa_K784001===
 
===Applications of BBa_K784001===
 
The graph below presents the results of the experiment described. The absorbance at 380nm for each of the different concentrations of the inducer in a range of 0.5 μM to 500 μM on a logarithmic scale. The absorbance was calculated via different dilutions of the samples: dilutions by 0.5, by 0.25, and by 0.1. The error bars represent the processing of the data collected. The line at the bottom of the graph represents the basal level according to the control result- no IPTG induction. <br>
 
The graph below presents the results of the experiment described. The absorbance at 380nm for each of the different concentrations of the inducer in a range of 0.5 μM to 500 μM on a logarithmic scale. The absorbance was calculated via different dilutions of the samples: dilutions by 0.5, by 0.25, and by 0.1. The error bars represent the processing of the data collected. The line at the bottom of the graph represents the basal level according to the control result- no IPTG induction. <br>

Revision as of 15:33, 23 September 2012

Applications of BBa_K784001

The graph below presents the results of the experiment described. The absorbance at 380nm for each of the different concentrations of the inducer in a range of 0.5 μM to 500 μM on a logarithmic scale. The absorbance was calculated via different dilutions of the samples: dilutions by 0.5, by 0.25, and by 0.1. The error bars represent the processing of the data collected. The line at the bottom of the graph represents the basal level according to the control result- no IPTG induction.

As can be seen, the graph shows a small tendency to rise, but it's not clear enough. There are several explanations, one is that saturation has been achieved from lowest concentration measured, which shows both that the assay is highly sensitive and that a small amount of polymerase is enough to cause translation. The experiment should be repeated with either lower concentrations of IPTG or Catechol. The line at the bottom of the graph represents the basal level according to the control result- no IPTG induction.

User Reviews

UNIQ6da53c0b06b29d60-partinfo-00000000-QINU UNIQ6da53c0b06b29d60-partinfo-00000001-QINU