+ | ==our GFP Assay== | ||
+ | |||
+ | I746907 (T7 promotor with GFP) in pSB1A2 in BL21DE3 cells | ||
+ | |||
+ | change of medium to M63 (LB shows slight fluorescence itself) | ||
+ | |||
+ | '''Problem''': measurement of Absorbance only every 100 minutes led to spikes in the diagram | ||
+ | |||
+ | ====results==== | ||
+ | |||
+ | no concentration dependency of GFP induction as IPTG concentration was in saturation range | ||
+ | |||
+ | for this diagram: | ||
+ | * calculated: Fluorescence/Absorbance | ||
+ | * mean of triplicate measurement | ||
+ | * adjusted to 100 % | ||
+ | * corrected for outliers | ||
+ | * shortened to 700 min | ||
+ | |||
+ | |||
+ | <!-- DON'T DELETE --><partinfo>BBa_I746907 StartReviews</partinfo> | ||
+ | <!-- Template for a user review | ||
+ | {|width='80%' style='border:1px solid gray' | ||
+ | |- | ||
+ | |width='10%'| | ||
+ | <partinfo>BBa_I746907 AddReview number</partinfo> | ||
+ | <I>TU_Munich team 2011</I> | ||
+ | |width='60%' valign='top'| | ||
+ | enter your review here. | ||
+ | |}; | ||
+ | |||
+ | <!-- End of the user review template --> | ||
+ | <!-- DON'T DELETE --><partinfo>BBa_I746907 EndReviews</partinfo> |
Revision as of 14:26, 21 September 2011
This experience page is provided so that any user may enter their experience using this part.
Please enter
how you used this part and how it worked out.
Applications of BBa_I746907
User Reviews
TU_Munich Team 2011
We tested the part and it worked very well.
our GFP Assay
I746907 (T7 promotor with GFP) in pSB1A2 in BL21DE3 cells
change of medium to M63 (LB shows slight fluorescence itself)
Problem: measurement of Absorbance only every 100 minutes led to spikes in the diagram
results
no concentration dependency of GFP induction as IPTG concentration was in saturation range
for this diagram:
- calculated: Fluorescence/Absorbance
- mean of triplicate measurement
- adjusted to 100 %
- corrected for outliers
- shortened to 700 min