Template:USTC//K176138

data

K176140

AHL(M) T(h) OD600 FLU(arbitrary) FLU/OD600(arbitrary) ST.FLU/OD600(ustc_st1)
0 0.5 0.236666667 2.070666667 8.749295775 34.96920773
1.00E-10 0.5 0.237666667 1.967 8.276297335 33.07872636
1.00E-09 0.5 0.246 4.862666667 19.76693767 79.00454704
1.00E-08 0.5 0.242666667 4.767 19.64423077 78.51411179
1.00E-07 0.5 0.237666667 5.182 21.80364656 87.14487036
1.00E-05 0.5 0.24 5.683 23.67916667 94.6409539
0 1.5 0.417666667 2.472 5.918595371 23.65545712
1.00E-10 1.5 0.415 3.980666667 9.591967871 38.33720172
1.00E-09 1.5 0.413333333 149.79 362.3951613 1448.421908
1.00E-08 1.5 0.405333333 132.8333333 327.7138158 1309.807417
1.00E-07 1.5 0.402 136.3766667 339.2454395 1355.89704
1.00E-05 1.5 0.396 134.04 338.4848485 1352.857108
0 3 0.616 6.812 11.05844156 44.19840751
1.00E-10 3 0.651666667 11.56666667 17.74936061 70.9406899
1.00E-09 3 0.616 635.81 1032.159091 4125.336095
1.00E-08 3 0.608 646.3333333 1063.048246 4248.793947
1.00E-07 3 0.605 655.2066667 1082.986226 4328.482118
1.00E-05 3 0.594 696.75 1172.979798 4688.168657

For the details of the definition of ST.FLU and the unit ustc_st1, please click here.

plot

Figure 2- this steregram shows the response of K176138 to both time and AHL. From this gram, we can see that the GFP expression reaches its top at some definite AHL(1.E-08) concentration at any time in the range of allowable error.