Part:BBa_K1058009:Experience

Designed by: Yunjie Qiu   Group: iGEM13_BIT   (2013-08-31)

This experience page is provided so that any user may enter their experience using this part.
Please enter how you used this part and how it worked out.

Applications of BBa_K1058009

We prepared a series of bera-lactam solution of which the concentration was respectively 0μg/mL, 10μg/mL, 20μg/mL, 30μg/mL, 5μg/mL, 100μg/mL and 200μg/mL, then we add the solution to the bacteria liquid with BBa_K1058009 of which the OD is around 0.2~0.3 with the ratio of 1:1000 respectively, and the concentration of beta-lactam in the environment of the engineering E.coli in 8 different tubes is respectively 0ng/mL, 10ng/mL, 20ng/mL, 30ng/mL, 5ng/mL, 100ng/mL and 200ng/mL. The samples were taken to two 96-well plates once per hour or once per 30 minutes. The intensity of green fluorescence was tested with a fluorescence microplate reader. The results are as follows.

Bla1.jpg

Bla2.jpg

We constructed the beta-lactam sensor BBa_K1058009 successfully. The characterization data of the beta-lactam sensor showed a great linear relationship between the fluorescence intensity and the concentration of the beta-lactams to be detected in a certain range (0-200ng/mL for the beta-lactam sensor).